MCP SG1638N User manual

OPERATOR’S MANUAL
SG1638N
FUNCTION GENERATOR/COUNTER

1
INTRODUCTION
Thank you for buying SG1638N series function generator/counter.
Please read this manual carefully before operation and keep it well.
Suggest to use an oscilloscope to watch the waveform when operation.
Please select the real input voltage by the voltage selector
Instrument’s AC power supply should have safe GND.
Changing fuse should be fit for given request.
Each output, input port should not contact AC power supply.
Each output, input port should not contact over ±35V AC or DC power.
Output port should try to avoid long-time short circuit. (≤1min)
In order to ensure instrument’s accuracy, please avoid strong magnetoelectricity.
1. Specifications:
1.1 Main output:
Model SG1638N
Output frequency 0.2Hz~2MHz
Frequency step six-step, decimalism
Frequency adjustment ratio Rate: 0.1~1 Range: 0.2~2
Output waves sine、square、triangle、pulse、ramp、and 50Hz sine
Output impedance 50Ω±10%
Output signal type single、VCF
VCF 0~10V
Output amplitude 20Vp-p (1MΩ) 10Vp-p (50Ω)
Output protection short circuit, resist input voltage: ±35V (1min)
Distortion of sine waves ≤100k 2%
Duty adjustment 20%~80%
DC offset ±10V (1MΩ) ±5V (50Ω)
Rising time of square wave 100ns 5Vp-p 1MHz
Attenuation accuracy ≤±3%
Effect of duty on frequency ±10%
1.2 TTL out
Model SG1638N
Output amplitude “0”:≤0.6V; “1”: ≥2.8V 600Ω

2
1.3Frequency counter:
Model SG1638N
Measurement accuracy
6digits±1% ±1word
Resolution 1Hz
frequency range 1Hz~15MHz (200mV)
1.4 Power:
Voltage: 220±10%V /110±10%V (Switchable) Frequency: 50±2Hz/60±2Hz
Visual power: 10VA prox.; Fuse: 0.5A
1.5 Physical characteristics:
Weight: Appro. 3kg Dimensions: 210(W)×80(H)×230(D)(mm)
1.6 Environment conditions:
Working temperature: 0~40ºC Storage temperature: -40~60ºC
Max working humidity: 90%(40ºC) Max storage humidity: 90%(50ºC)
Other demands: continually vibrate and impact should be avoided. No acid、alkali、and hydrochloric air
2. Panel operation Summary:
SG1638N Function Generator Front Panel
(1) Power: spring out means “off”. Connect the power line. Push down the knob and power is
on.
(2) LED window: this window indicates the frequency of output signal, when “EXT” is on, it
displays frequency of external signal. If over the measurement range, the light “overflow”
is on.
(3) Frequency: adjust this rotary to change output frequency signal, the frequency will be big
while turn it clockwise.
(4) Wave form: choose the wave you need if you press the correspondence key.
(5) ATTE: The voltage output attenuate switch, two-switch combination is 20db, 40db, 60db.
(6) Frequency range selector: (frequency counter gate switch): Press one key according the
needed frequency.
(7) Counter/Frequency terminal: Counter, EXT frequency input terminal.

3
(8) EXT frequency switch: Press this switch, LED window will display EXT signal frequency
or counter value.
(9) Level adjustment: Press level adjustment switch, the light “level” is on, then adjusting
level adjustment rotary can change DC level offset.
(10) Amplitude: The voltage output amplitude will be big while turning it clockwise, and the
value will be small while turning it counterclockwise.
(11) Voltage out: voltage is out via this terminal.
(12) TTL out: TTL is out via this terminal.
(13) VCF: Voltage controlling frequency change input is via this terminal.
(14) SYMMETRY: sym switch, duty adjustable rotary, press duty switch, the light “SYM” is
on; adjusting duty rotary can change the duty of wave.
3. BASIC OPERATION METHODS:
Before power is on, fist check the input voltage, insert the power line into the AC socket in
the rear panel. Set each controlling knob as the following table:
POWER Knob Spring out
ATTE Knob Spring out
COUNTER Knob Spring out
LEVEL Knob Spring out
DUTY Knob Spring out
After that, turn on the switch. The function signal generator acquiesce 10k sine wave, LED
window display it’s out signal frequency.
5.1 Deliver the voltage out signal to oscilloscope Y input terminal via amplitude terminal.
5.2 Triangle、square、sine wave form:
5.2.1 Press sine、square、triangle wave, the screen of oscilloscope will display sine、square、and triangle.
5.2.2 Press frequency range selector and rotate the frequency rotation, the waveform on the oscilloscope’s screen and
frequency on LED window will change evidently.
5.2.3 Turn the amplitude rotary to maximum, the wave amplitude on the oscilloscope’s screen will be ≥20Vp-p
5.2.4 Press “LEVEL”, turn the “level” rotary to max, wave on oscilloscope will move upside, and vise visa. The max change
should be ±10V or more. NOTICE: when signal is over ±10V or ±5V (50Ω),the amplitude is limited.
5.2.5 Press “ATTE”, the out waveform will be attenuated.
4. INSTRUMENT ACCESSORIES:
The standard accessories are as following:
(1) Function Signal Generator 1 set
(2) Connect cable 1 piece
(3) Operation manual 1copy
(4) Fuse 1piece
(5) Power cord 1piece
Table of contents
Popular Portable Generator manuals by other brands

Leviton
Leviton 83A00 installation manual

Snapper
Snapper 30214 Illustrated parts list

Fabco Power
Fabco Power HYDRO 300X6 instruction manual

Leroy-Somer
Leroy-Somer LSA 37 AREP Series Installation and Maintenance

King Canada
King Canada POWER FORCE KCG-5100G instruction manual

Cristec
Cristec 12V / 10A operating manual