
5
1-WARNINGS ANDWARRANTY CONDITIONS
Technical Dept. - All rights reserved - Reproduction prohibited
INFORMATION:
Please contact the retailer or qualied personnel authorised by the company to resolve a problem.
• Only use the fuel specied by the manufacturer.
• When the product is switched on for the rst time, it is normal for it to emit smoke due to the paint heating up for the rst time.
Therefore make sure the room it is installed in is well-ventilated.
• Check and clean the smoke outlet pipes regularly (chimney tting).
• The product is not a cooking appliance.
• Always keep the cover of the fuel hopper closed.
• Store this installation and user manual with care as it must accompany the product for the duration of its useful life. If the product
is sold or transferred to another user, always ensure the manual is also handed over.
INTENDED USE
The product only works with wood pellets and must be installed indoors.
PRODUCT PERFORMANCE CHECKS.
All our products undergo ITT TESTS carried out by a notied third party laboratory (system 3) and in accordance with Regulation (EU)
number 305/2011“Construction products”, according to standard EN 14785:2006 for household appliances and“Machinery Directive”EN
303-5 for boilers.
In the case of tests for any market surveillance or inspections by third parties, please consider the following warnings:
• To reach the declared performance levels, the product must perform an operating cycle of at least 15-20 hours beforehand.
• Set the average draught of the combustion fumes as specied in the“technical product features”table
• The type of pellets used must comply with the current EN ISO 17225-2 class A1 regulation. Fir pellets are usually used for certication.
• The amount of thermal energy can vary according to the length and caloric value of the fuel. This may require some adjustments
(accessed from the user menu) to comply with the hourly consumption specied in the“technical product features”table. Using class
A1 pellets guarantees a caloric value that is likely to be close to that used in the product certication; the size of the pellet grains can
signicantly aect hourly fuel loading and consequently performance; it is therefore suggested to use pellets with a 6 mm diameter
and an average length of around 24 mm (avoid pellets that are too long or excessively crushed).
• With wood-burning appliances, the fuel must comply with the current EN ISO 17225-5 class A1 regulation. Check the correct moisture
of the fuel, as it must be within the range of 12 - 20% (it is best if the moisture is close to 12%, as is normally used in certication). As
the fuel moisture increases, dierent combustion air settings are required, which are implemented from the combustion air register,
thereby modifying the mixture of primary and secondary air
• It is important to check the operation of devices that can aect performance (for example air fans or electric safety devices) in case
of damage due to handling.
• Nominal performance has been obtained by setting the maximum ame power and room ventilation in manual mode.
Performance at reduced power was achieved at minimum ame and ventilation power (P1 andV1) in manual mode.
The other conditions (COMFORT SET) correspond to intermediate ventilation and power.
• If a “verication” mode is provided in the menu, set this function during the readings to ensure that no temperature modulation
occurs due to an incorrect setting of the operating parameters.
• Lastly, strictly comply with the withdrawal points specied in the regulations in terms of emissions as well as temperature
WARRANTY CONDITIONS
The company guarantees the product, with the exception of parts subject to normal wear (listed on the following page), for a
period of 2 (two) years from the date of purchase attested by:
• a document that serves as proof of purchase (invoice and/or receipt) that shows the name of the vendor and the date that the
purchase was made on;
• forwarding of the completed warranty certicate within 8 days of purchase.
Furthermore, in order for the warranty to be valid, the device must be installed and calibrated by qualied personnel, and where necessary,
the user must be issued with a declaration of conformity and correct product operation.
We recommend testing the product before completing the relative nishes (cladding, painting walls, etc.). Installations that do not meet
the current standards, improper use and lack of maintenance as required by the manufacturer, void the product warranty.
The warranty is valid on the condition that the instructions and warnings contained in the user and maintenance manual are observed,
and therefore the product is used correctly.