MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
Page 7
+617 3283 4536
Free AU 1800 669 006
Trouble Shoong:
Issue Possible Cause Soluon
Replace baery
indicator ashes
Lack of Power Replace the baeries
Body Failure Take out baeries rst, wait for 30 minutes then reload the
machine, let the sensor automacally set again.
Inducon / Power
indicator no icker,
no acon
Body Failure Take out baeries rst, wait for 30 minutes then reload the
machine, let the sensor automacally set again.
Incomplete during the inial automac
seng process
Insucient power or incorrect baery
polarity installaon
Please replace the baery.
Please check if the posive and negave baeries are in-
stalled correctly.
The baery is not covered Please pay aenon to whether the baery cover is stuck or
not closed.
Fixed obstacles (such as toilet paper) with-
in 10cm of the front of the sensor
Please remove the obstacles and keep the distance of 130cm
or more. The system will automacally reset and return to
normal aer 30 minutes.
The sensor detects obstacles or reecve
objects (mirrors, walls, boards, cabinets or
various xtures)
Please remove obstacles mirrors or reecve objects and
keep a distance of at least 130cm
Sensing / Power
indicator blinks
connuously
The sensor is placed too low and is
blocked by the toilet cover.
Please adjust the sensor posion so that the sensor window
exceeds the top edge of the toilet lid.
When the system is automacally set, it
senses someone or a dynamic object.
Take out baeries rst, wait for 30 minutes, then reload it, let
the sensor automacally set again, make sure there is no ob-
ject within 130 cm in front of the sensor.
Sensor surface has stains Please be careful to avoid scratching, so as not to aect the
infrared sensing distance.
The toilet in which the sensor is installed is
less than 130 cm from the wall.
A toilet with a minimum of 130 cm or more from the wall in
front of the sensor can be used.
Bad Baery Please replace the baery
Baery Life is too
short Lack of power Please replace the baery (use the lithium or alkaline baery
produced within half a year to maintain the best use me).
Not sensing or
need to be very
close
Sensing window surface with stains or
water droplets
Gently wipe the sensor window to avoid scratching, so as not
to aect the sensing window
There is an obstacle in front of the sensor
when it is automacally set for the rst
me.
Take out the baery rst, wait for 30 minutes, then re-load it,
let the sensor automacally set again , make sure there are
no obstacles within 130cm of sensor.