MEI Cashflow 9500 User manual

Quick Reference Guide
1Diagnostic LED
2 i™Button Contacts
3 Service Tool Connector (i.e. CPM)
4 HII Interface Connector (i.e. Serial)
5 Route Inhibit Connector
6 Configuration Switches
7 Machine Interface Connector
8 Reject Lever
MEI
Eskdale Road,
Winnersh Triangle,
Wokingham, Berkshire, RG41 5AQ
http://www.meiglobal.com
Order - CF9500 Quick Reference Card Rev G2 - 2003
Coin Route Teach (Continued)
Example:- How to set a route C on a CF9524?
1) Power machine OFF
2) Set switch 7 to ON
3) Power machine ON
4) Press reject lever 3 times
(light will cycle the following sequence)
5) Insert required coins to be routed
6) Set switch 7 to OFF
Token 1 & Token 2 Teach
Switch 5 - Token 1 Teach - Switch 6 - Token 2 Teach
These switches allow you to teach tokens into 2 Token Channels.
Follow the instructions below to teach a token.
Coin Route Teach
Switches 7 and 8 - Route Teach
The acceptor has 4 routing priorities depending on the route inhibit
status, the first 3 routes can be taught using switches 7and 8.
The order of priority is primary, secondary then tertiary.
E.g. If the primary route is full, the secondary route is then selected.
On a CF9524, route 'A' is the default route and on CF9528 route '8'.
All CF9500 acceptors leave the factory programmed with "all coins
to the default route".
To program a route, the reject lever will need to be pressed a
specific number of times. The Green light will flash a number of
times indicating the route selected. (See table below)
No.ofRejectLeverPresses 01234567
No of Green Flash Codes 8 7 6 5 4 3 2 1
Route Selected (CF9524 - 4 way) a b d c B A C D
Route Selected (CF9528 - 8 way) 8 7 6 5 4 3 2 1
Route Inhibit Connector Pin No. 8 7 6 5 4 3 2 1
2
3
4
5
6
7
1
8
Step Light Operation and Action Required
Power Machine OFF
For Primary Route Set switch 7 to ON
For Secondary Route Set switch 8 to ON
For Tertiary Route Set switches 7 & 8
ON
Power Machine ON
Press Reject lever the number of times
for the required route.
Insert the coin for the required route
Inserted Coin Recognised – OK
Coin NOT Recognised (re-insert coin).
For Primary Route Set switch 7 OFF
For Secondary Route Set switch 8 OFF
For Tertiary Route Set switches 7 & 8
OFF
Route Taught – OK
Error - Re-try Route Teach again.
+ ?
Slow
Rapid
1
2
3
4
5
6
7
Step Light Operation and Action Required
Power Machine OFF
To Teach Token 1 Set switch 5 to ON
To Teach Token 2 Set switch 6 to ON
Power Machine ON
Insert Sample Tokens slowly. (min. x 20)
If inserted Token was recognised the
green light will flash once
When approx. 20 Tokens have been
inserted, CF9500 will flash the green light
rapidly
Set switch 5 to OFF ends Token 1 Teach
Set switch 6 to OFF ends Token 2 Teach
Tokens taught - OK
Error – Re-try teach again
Slow
Rapid
Rapid
1
2
3
4
5
6
7
CF9524 & CF9528 Separator Diagram
CF9524 Separator
(4 way)
D
A B
C
CF9528 Separator
(8 way)
END VIEW
TOP VIEW
Coin Reject
1
2
3
4
6 578
Coin Tube Exits
Cash Box Exits
GB

LED Light Codes
Normal Operation
No power on product
CF9500 Working OK
CF9500 Faulty
Coin Accepted by CF9500
Coin Unrecognised by CF9500
Coin Inhibited by CF9500
Coin Inhibited by Machine
1 x Flash
2 x Flashes
3 x Flashes
4 x Flashes
OFF
☺
Switch 1 - Setting the Alarm
When switch 1 is set to ON the alarm feature is enabled. The
Alarm will not be active until the first coin has been inserted. The
Alarm can be switched ON or OFF at any time without the need to
turn off the power to the CF9500.
Configuration Teach Switches
There are 8 teach switches located behind the cut out section of
the reject cover (see item 6 on front page). These switches enable
the key CF9500 settings to be altered by way of unique teach
modes.
To enter a “Teach Mode”, the power of the CF9500 must be turned
OFF. Using the relevant teach mode switches select the required
“Teach Mode” (see table below) and then turn the power to the
CF9500 ON again.
Note: - Only one teach mode can be set at any one time. However
switch 1 is used to set the alarm to either ON or OFF and is
therefore independent of the other 7 switches.
Note: -
When in teach mode a 30-second timeout will apply. If
there is no activity within this time or if an error has occurred, a red
light will flash rapidly. In this case, no changes will have been made
and you will need to start the teach process again.
Switch 2 – HII Standalone Mode (Serial Mode Only)
This mode is intended for users that want to interface their
machines using HII interface only.
When switch 2 is set to ON, the CF9500 will then operate in
serial mode.
This feature can be selected provided the validator power is
cycled OFF and ON.
Note:- When in this mode, coin and route inhibits will be
disabled. However, the output line will remain active.
To inhibit or route coins the machine will need to send a
command to the CF9500 validator.
Configuration Teach Switches Continued
Switch 3 - Enable a Coin(s) - Switch 4 – Inhibit a Coin(s)
These switches change the state of the accepted coin(s) from
Inhibited to Enabled and vice versa.
Follow the instructions below to either Enable or Inhibit a coin(s):
Enable and Inhibit Coins
Enable / Inhibit Coin LED Light Codes
Insert coin sample in CF9500
Program Error
Inserted coin recognised
Inserted coin unrecognised
Inserted coin stored in memory
Slow Flash
Rapid Flash
4 x Flashes
i™Button Memory Device
The i™Button is a memory device used to transfer coin routing
and inhibit information from one CF9500 acceptor to another
CF9500.
Note: - The CF9500 does not use routing plugs.
i™Button Functions
CF9500 is programming the i™Button
i™Button Programmed OK
i™Button Program Error (re-try)
i™Button Programming a CF9500
No Error - Program completed OK
Rapid Flash
Rapid Flash
Rapid Flash
Slow Flash
How to Program a CF9500 with the i™Button?
Step Light Operation and Action Required
Place i™Button on to i™Button Contacts
Light will flash and Accept Gate will click
Remove i™Button from contacts
Press & Release Reject Lever to confirm.
Accept Gate will click
CF9500 Programmed OK
Error - CF9500 Failed Program (re-try)
Rapid
Slow
How to program the i™Button from a fully configured CF9500?
Step Light Operation and Action Required
Press & Hold Down the Reject Lever
Place i™Button on to i™Button Contacts
Light will flash, also Accept Gate will buzz
Remove i™Button from Contacts
Release the Reject Lever
i™Button Programmed OK
Error - i™Button not programmed (re-try)
Slow
Rapid
Rapid
Description Turn Power Off &On
Alarm Enable Not Required
HII Standalone Mode Yes
Enable Coin Yes
Inhibit Coin Yes
Teach Token 1 Yes
Teach Token 2 Yes
Primary Route Teach Yes
Secondary Route Teach Yes
Tertiary Route Teach Yes
1
2
3
4
5
6
7
8
7
+
8
Slow
Step Light Operation and Action Required
Power Machine OFF
To Enable a coin Set switch 3 to ON
To Inhibit a coin Set switch 4 to ON
Power Machine ON
Insert coin(s) to be Enabled or Inhibited.
Inserted Coin Recognised - OK
Coin NOT Recognised (re-insert coin)
Set switch 3 to OFF Ends Enable Teach
Set switch 4 to OFF Ends Inhibit Teach
Coin Accepted / Inhibited - OK
Error - Re-try Teach again.
Slow
Rapid
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
OFF
Switch
Down = OFF
ON
Switch
Up = ON
Slow
Other MEI Cash Counter & Coin Sorter manuals

MEI
MEI Cashflow 690 series Reference guide

MEI
MEI CASHFLOW 7000 Series User guide

MEI
MEI Cashflow 690 series Reference guide

MEI
MEI SCR User manual

MEI
MEI CASHFLOW 8000 Series User guide

MEI
MEI CASHFLOW 7000 Series User guide

MEI
MEI EC6000 Manual

MEI
MEI Economy Series User manual

MEI
MEI TRC Series User manual

MEI
MEI cashflow VN2700R User manual