Menvier DC58 Operating instructions

DC58 & DC58M Installation &DC58 & DC58M Installation &
Programming Guide OverviewProgramming Guide Overview
General
The DC58/58M digital communicator consists of a
single PCB fitted in a small polycarbonate case. It is
used to transfer status information from an alarm
system to a dedicated Alarm Receiving Centre (ARC)
via the Public Switched Telephone Network (PSTN). The
DC58MoffersthesamefeaturesastheDC58butitalso
functions as a V21 modem. The DC58M is required
when using the up/downloading feature on
compatible Menvier Security control panels.
Operating Modes
The DC58 can be used as a stand-alone
communicator, in this mode the communicator is
hard-wired to the control panel using the appropriate
terminal block connections. Alternatively the unit can
be plugged on to a suitable Menvier Security control
panel, such as the TS510, TS700, TS790, TS900, TS2500
or TS2200. When used in this mode the communicator
plugs on to the control panel using the lead supplied.
The DC58M can only be used in the plug-on mode.
NVM Programming
All programmed data is stored in a plug-in NVM
(Non-Volatile Memory) which will be retained for up to
five years with no power present. The NVM can be
programmed by using a Menvier Security LCD Remote
Keypad (P/No. NETLCD) and an engineer's interface
lead (P/No. NETEKI) which will plug directly on to the
DC58/58M.AlternativelytheNVMcanbeprogrammed
using the desktop programmer PP5.
Your ARC will normally provide a programming service
and will supply a pre-programmed NVM on request.
Technical Specifications
Supply: 11.5V - 14V; 35mA dc (Standby);
100mA dc (Active)
The installer must ensure that
power drawn by the DC58/58M
plusanyotherauxiliaryapparatusis
within the rating of the control
panel (host) power supply.
Low Battery: Detection threshold is at 10.8V +/-
0.2V
Outputs: [1+]: Switched +ve @100mA
[2-]: Switched -ve @100mA
Ch1-8: Maximum input voltage 28V.
Channel input trigger either +ve or
-ve applied (JP3)
Modem: 300 Baud (V21)
Programmer: NETLCDremote keypad& NETEKIor
PP5.
Case Size: 142(w) x 82(h) x 36(d) mm.
Weight 265g
REN value: 0.0
BT Approval: DC58 - S/1100/3/R/503310
DC58M - S/1100/3/R/503311
Series Voltage Drop
The voltage drop introduced by the series connection
throughtheDC58/58Matalinecurrentof40mAis0.1V.
When used with other apparatus (telephone, fax etc.)
thetotalvoltagedrop@40mAMUSTNOTexceed2.0V.
496545 Issue A 1of8 DC58 & DC58M
DC58 & DC58M
Plug-on Mode
Stand-alone Mode
(DC58 Only)
T
erminal
connections for
other control
panels NETLCD Remote Keypad
(Programmer)
NETLCD Remote Keypa
d
(Programmer)
Plug-on to
Menvier Security
control panels
Figure 1. Operating Modes

Installation
1 Output 2- (SELV)
Programmable switched -ve output rated
@100mA.
2 Output 1+ (SELV)
Programmable switched +ve output rated
@100mA.
3 Power Input (SELV)
12V power input, only use in stand-alone mode.
4 CH1 - CH8 (SELV)
Inputchannels1-8,onlyuseinstand-alonemode.
5 JP5
Input channel trigger polarity, stand-alone mode
only.
[+] = +ve applied (0V going to 12V)
[-] = -ve applied (12V going to 0V)
6 LED 1
Activity LED. On whilst communicator is active.
Flashes on and off 4 times when successfully
communicated with the ARC. Flashes continuously
when modem is in operation.
7 Test Call
Short these two pins to initiate a test call.
8 NVM
Removable Non-Volatile Memory used to store all
programmed data.
9 JP2 (SELV)
Connector for Menvier Security control panels.
10 JP1 (SELV)
Connector to NETLCD/TS900 remote keypad
(Programmer).
11 Telephone Connections (TNV)
Terminal connections to the telephone line.
12 HI/LO SECURITY
Line fault monitoring level:
Link fitted = High Security (Line Out, Incoming
Ringing, Line Voltage)
Link removed = Low Security (Line Cut only)
DC58 & DC58M
DC58 & DC58M 2of8 496545 Issue A
CH1CH2CH3CH4CH5CH6CH7CH8
12V 0V 1+ O/P 2-
A
A1 B
B1 BC
NVM
TEST
JP5
Trig
Polarity
TS900
REMOTE
TO CONTROL
PANEL
JP2
JP1
HI/LO
SECURITY
-+
12
1
2
3
4 5
6
10
7
8
9
11
Figure 2. DC58 PCB Layout
A
A1 B
B1
TS900
REMOTE
TO
CONTROL
PANEL
9
10
11
HI/LO SECURITY
TEST
CALL NVM
67812
JP 2
JP1.
Figure 3. DC58M PCB Layout

Plug-on Installation
1. Isolate ALL power from the control panel (battery
and mains).
2. Do not attempt to continue if the mains or battery
supply is still present.
3. Remove the cover from the DC58/58M case and if
appropriate fit a pre-programmed NVM.
4. Connect the interface lead to the control panel
connector(DIGIMODEM)viathecableentryholein
the base, then connect the lead onto JP2 on the
DC58/58M (marked TO CONTROL PANEL).
5. Set the "HI/LO SECURITY" link to the appropriate
setting.
6. Secure the DC58/58M base to the control panel
base using the self-adhesive pads.
7. Refer to "Telephone Line Connections".
Stand-alone Installation (DC58 Only)
1. Isolate ALL power from the control panel (battery
and mains).
2. Do not attempt to continue if the mains or battery
supply is still present.
3. Remove the cover from the DC58 case and if
appropriate fit a pre-programmed NVM.
4. Connect the input channels to the appropriate
outputs on the control panel feeding all cables
through the cable entry hole in the base.
5. Ensure that "JP5" is set for the appropriate polarity.
6. Connect 12V and 0V to the control panel digicom
supply, if a line fault output is required use output 1
or 2 and program the output as line fault.
7. Set the "HI/LO SECURITY" link to the appropriate
setting.
8. Secure the DC58 base to the control panel base
using the self-adhesive pads.
9. Refer to "Telephone Line Connections".
Telephone Line Connections
1. Connection to the telephone network must be
made via an NTE5 master socket (Line Box).
2. Using the cable type 1/0.5mm CW1308, strip back
5mm of the required cores and feed through the
DC58/58M cable entry, see Figure 4.
☞Keep all telephone cables at least 5mm
away from other alarm cables.
3. CW1308 cable is available from RS Components
(PartNo.368-413).Alarmoranyothertypeofcable
must not be used.
4. Connect the three cores to the terminal blocks
marked A, B and BC.
5. Remove the two screws from the BT master jack
socket and remove the bottom section from the
master jack.
6. Connect the cable from A, B and BC terminals on
the DC58/58M to the BT master jack terminals, see
Figure 4 .
496545 Issue A 3of8 DC58 & DC58M
DC58 & DC58M
A
A1B1 B
BC Cable Entry
Telephone cable
Type 1/0.5mm CW1308
Telephone line to
"series connected"
telephone, Fax etc.
A = 5 - White/Blue ring
B = 2 - Blue/White ring
BC= 3 - Orange/White ring
3
2
1
6
5
4
Figure 4. Telephone Line Connections

7. A special insertion tool will be required to connect
the cable to the master jack, this is available from
RS Components (Part No. 470-487).
8. Replace the bottom section of the master jack
socket and do up the two screws. Refer to "Testing"
(see below).
NETLCD Remote Keypad Connections
To convert a standard NETLCD/TS900 remote keypad
intoaDC58/58Mprogrammerthefollowingisrequired:
NETLCD 32 character LCD remote keypad.
NETEKI Networker Engineer's Keypad
Interface lead.
Testing
Once all the installation steps have been completed,
proceed as follows:
1. Ensurethat you have informedthe ARC that youwill
be sending test calls.
2. When used in the stand-alone mode, ensure that
any unused reporting channels are linked to their
healthy condition or programmed not to report,
e.g.,ifchannel4 is programmedtoreportbutisnot
connectedtothecontrol panel, then link itto+12V
ifthe triggeris set to -ve or to 0V if the trigger is set to
+ve.
3. Connect power to the control panel. If the DC58 is
being used as a stand-alone, wait for
approximately 10 seconds for the unit to
automatically configure itself.
(a) If the NVM is un-programmed or fitted
incorrectly the red LED will flash rapidly.
(b) If the DC58/58M is to be programmed using
the NETLCD/TS900 remote keypad, plug it onto
the connector labelled "TS900 REMOTE". Refer
to "Programming" for further details.
(c) If at the end of the 10 seconds any input
channelis active the red LEDwill illuminate and
the dialling sequence will commence.
4. Send a test call by momentarily shorting the "TEST
CALL" pins together, see Figures 2 & 3 . This will
initiate a test transmission to the ARC.
☞The DC58/58M will not send a test call if
there is a parallel hand-set off hook.
5. Trigger all the relevant channels by:
(a) Setting and unsetting the control panel to send
open/close signals.
(b) Set the system and cause a full alarm to send
an intruder signal.
(c) Press any PA buttons to send a PA signal.
(d) Activateanyotherdevicesthatrequiretesting.
6. UnplugtheNETLCD remote keypadand secure the
cover of the DC58/58M using the two screws
supplied.
7. Finallyreplaceandsecurethecover on the control
panel.
DC58 & DC58M 4of8 496545 Issue A
DC58 & DC58M
Set I/D to "ENG"
NETEKI Lead
Pol.
TSNETLCD/TS900 Remote Keypa
d
Blue
White
Yellow
Black
Red AB
REMOTE
I/D
1
2
3
4
ENG
CDE
O/P-
Figure 5. Engineer’s Keypad Connections

Programming
Programming Menu
DC58 & DC58M
496545 Issue A 5of8 DC58 & DC58M
TELEPHONE NO.1
018112345678
TELEPHONE NO.2
018112345687
REPORTS TO NO.1
**34***8
Press any key
=Clearnumber
A
= Pulse Dial (P) or Pause (-)
B
=ToneDial(T)
C
DC58 Version 2.2
Press Any Key
Enter Telephone No. 2
ACCOUNT NO.1
0001
TELEPHONE NO.3
018112345679
Enter Telephone No.3
Enter account No.1
ACCOUNT NO.2
0001
ACCOUNT NO.3
0001
Enter account No. 2
Enter account No. 3
Select channels that report
to tel No.1 by pressing [1] - [8]
REPORTS TO NO.2
*234***8
REPORTS TO NO.3
*234***8
Select channels that report
to tel No.2 by pressing [1] - [8]
Select channels that report
to tel No.3 by pressing [1] - [8]
SET/DAY CHANNELS
***4****
Select Set/Day (Open/Close)
channels by pressing [1] - [8]
RESTORE CHANNELS
**34****
Select Restore channels
by pressing [1] - [8]
= Consecutive
= Alternative
=All
1
2
3
=WillNOTReport
=LimitedReport
= Full Report
1
2
3
Dialling Mode
is Consecutive
Extended Format
Will NOT Report
Select dialling mode:
Select point ID reporting mode:
TEST CALL PERIOD
Disabled
T.O.S Calls are
Disabled
Select test call period:
Select Temporary Out of
Service monitoring period:
= Disabled
=Daily
= Weekly
1
2
3
= Fortnightly
4
= Disabled
=Daily
= Weekly
1
2
3
= Fortnightly
4
Digi Output 1 is
Line Fault
INVERT CHANNELS
********
Select Invert channels
by pressing [1] - [8]
Select output type:
= Line Fault
= Digi Successful
= Digi Failed
1
2
3
=DigiActive
4
= Serial Coms Fault
5
Digi Output 2 is
Line Fault
Select output type:
= Line Fault
= Digi Successful
= Digi Failed
1
2
3
=DigiActive
4
= Serial Coms Fault
5
Ring Count is
Instant
= Instant
= Delayed
1
2
Select Ring Count
(DC58M Only):
= Disable
=Enable
1
2
3-WAY CALLING
Enabled
Enable/Disable 3-way calling
Enter Telephone No.1

Point ID Extended Format
Whenthe DC58/58Mis usedin the"plug-on mode" (i.e.
connected to a Menvier Security control panel) it is
possible to send additional alarm information to the
ARC, this can include circuit and user ID.
☞This feature is only supported by relevant
Menvier Security control panels, for details on
which control panels support this feature
contact Menvier Security Technical Support.
Point ID can be set to one of the following reporting
options:
1 Will NOT Report
This disables "Point ID Extended Format" and the
DC58/58M will only report "Fast Format" data to the
alarm receiver.
2 Limited Report
When "Limited Report" is selected the DC58/58M
willonlyreporttheextendedformatdatarelating to
the channel that is triggered. For example, if the
DC58/58M is programmed to report channels 2
and 3 (PA and Intruder) then the unit will only report
events relating to PA and Intruder activations.
3 Full Report
When "Full Report" is selected the DC58/58M will
report all extended format data to the alarm
receiver irrespective of the channels that are
programmed to report. That is, if all eight channels
are programmed as non reporting, the unit will still
report all events to the ARC.
Temporary Out of Service
This feature is used to test the integrity of the telephone
line by dialling all but the last digit of the first telephone
number. If the unobtainable tone is NOT detected it is
assumed that the line is in good working order,
however, if an unobtainable tone is detected the
DC58/58M will signal a line fault condition.
Ring Count (DC58M Only)
The DC58M Ring Count can be programmed for one
of the following options:
1 Instant
The DC58M will answer any incoming calls
immediately.
2 Delayed
The DC58M will answer any incoming calls after
approximately 30 seconds.
☞Some Menvier Security control panels allow
the ring count to be performed by the
control panel. If the control panel has a ring
count option then set the DC58M to "Instant"
and program the panel ring count to the
required amount.
DC58 & DC58M 6of8 496545 Issue A
DC58 & DC58M

Monitor Mode
Introduction
When the NETLCD remote keypad is left plugged on to
the DC58/58M it will act as a monitor, so that during
testing to the ARC the display will show the
communicator's status.
Transmitted Data Specification
The data transmitted to the alarm receiver is industry
standard fast format. The data contains the following
information:
Account No This is a 4 digit number and is
unique to the installation site.
Channel 1-8 Each channel can report its own
status code:
Code 1 = New Alarm
Code 2 = System Opened
Code 3 = Channel Restored
Code 4 = System Closed
Code 5 = Healthy Channel
Code 6 = Previously reported
event
Channel 9 This channel is normally referred to
asthestatus channelandisusedto
report the following:
Code 7 = Normal
Code 8 = Low Battery
Code 9 = Test
Typical Test Call
When the "TEST CALL" pins are momentarily shorted the
DC58/58M will send a test call to all programmed
telephone numbers. The display should show:
Other Monitor Messages
The following monitor messages may also be
displayed:
496545 Issue A 7of8 DC58 & DC58M
DC58 & DC58M
DC58(M) MONITOR
Waiting for I.D
DC58(M) MONITOR
Sending Data
Dialling the first telephone No.
Waiting for the alarm receiver to
answer the call and send its
identification tone (I.D.).
The alarm receiver is on line
and the DC58 is sending its data.
The data sent is displayed.
This is repeated for all
programmed telephone
numbers
The data was accepted and the
alarm receiver has sent its
acknowledgment tone.
DC58(M) MONITOR
Dialling Number 1
DC58(M) MONITOR
0001 5555 5555 9
DC58(M) MONITOR
Call Successful
DC58(M) MONITOR
Unobtainable
DC58(M) MONITOR
No Ack. Tone
DC58(M) MONITOR
Engaged
DC58(M) MONITOR
T.O.S Call Ok
No dial tone detected when the
DC58 went on line.
The number was dialled but an
unobtainable tone was detected.
The alarm receiver is engaged.
The number was dialled but a
"Special Information Tone"
was detected.
No reply from the alarm receiver.
The "Temporary Out of Service" test
call was successful.
The DC58 sent its data to the
alarm receiver, but the receiver
failed to give an acknowledgement
tone (corrupted data).
DC58(M) MONITOR
No Dial Tone
DC58(M) MONITOR
S.I.T. Tone Found
DC58(M) MONITOR
No Answer

DC58 & DC58M 8of8 496545 Issue A
DC58 & DC58M
This page intentionally left blank