Metertech ZoneVu ZVR-530 Series User manual

MEYERTECH LIMITED
Office Block One
Southlink Business Park
Oldham OL4 1DE
Sales: +44 (0)161 628 8406
http://www.meyertech.co.uk
To obtain the optimum performance from your
ZVR-530-xxxx follow the installation guidelines
below.
WARNING!!
THIS EQUIPMENT MAY CONTAIN HAZARDOUS
VOLTAGES.
THIS EQUIPMENT MUST BE EARTHED TO PREVENT
FIRE OR SHOCK HAZARD.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR
MOISTURE.
Unpack the ZVR-530-xxxx and check you have
•ZVR-530-xxxx TELEMETRY RECEIVER
•ZVR-530-PSU (OPTIONAL ITEM)
•INSTALLATION GUIDE
•CONNECTION DIAGRAM
•UNIVERSAL BRACKET TEMPLATE
•USER and CONFIGURATION GUIDE
(OPTIONAL ITEM)
The ZVR-530-PCB has been designed to be installed within
the camera housing. Installing the ZVR-530 is straightforward
due to the universal mounting bracket it is attached to. A
template for the universal bracket is supplied with this guide.
If the ZVR-530 were installed inside a weatherproof box the
cabling to the ZVR-530 MUST be segregated according to
function, E.G. you would not want to mix mains with the head
feedback cabling. The correct type of cables should also be
chosen according to function EG you would choose a
screened cable for head feedback functions and similarly a
coax cable for the video. Never be tempted to run all the
functions in a multicore cable. To help wire the ZVR-530 use
the connection diagram provided with this guide.
The ZVR-530 requires 24VAC 50Hz +/-10% power.
Meyertech can supply, if required a suitable toroidal
transformer, Part number ZVR-530-PSU. Once all the cabling
has been connected to the ZVR-530, head, lens and camera it
can be tested using the self-test function which allows the
receiver to be exercised without the need for it to be
connected to a ZoneVu controller. To do this simply plug a
monitor into the video output of the receiver and press the self-
test button once to activate the Installation Menu.
Navigation of the menus using the self-test button is
easily achieved by following these simple guidelines.
Press and release the button once to display the
Installation Menu. To cycle down the menu press and
release the button again. To select a menu option press
and hold down the button for a second before releasing it.
When setting the address if the button is pressed and held
down for more than 3 seconds the address will
automatically increment itself. To exit a menu or complete
a setting, cycle through the menu until FINISH starts
flashing. Now press and hold down the button for 1sec
before releasing it.
If the memory of the ZVR-530 ever becomes corrupted, you
may be asked to reload factory defaults. This should only be
done as a last resort though because ALL previously
configured data will be lost. IE factory defaults will be restored
including the address. To load factory settings select Confirm,
otherwise select Cancel To return to the Installation Menu.
ZVR-530-xxxx
INSTALLATION GUIDE
SUPPORT LINES
(TEL: + 44 (0) 1724 278833
22 FAX: + 44 (0) 1724 289099
:: E-mail: [email protected]

The information in this Installation Guide is believed to be accurate and reliable. However, no responsibility or liability is assumed by Meyertech Limited for its use, or for any infringement of patents or other rights of third parties which
may result from its use. No license is granted by implication or otherwise under any patent or other rights of Meyertech Limited. All specifications are subject to change without prior notice.
AUTO TEST
Select Auto-Test from the menu. This tests the basic PTZF
functions by automatically cycling through and selecting each
of them for a few seconds. When the Auto Test is complete,
the Installation Menu is automatically exited.
TEST FACILITIES
From the Test Facilities menu you can test manually the
functions Pan, Tilt, Zoom and Focus, different speed settings
can also be tested from this menu.
Selecting any of the menu options Pan, Tilt, Zoom and Focus
will display a menu similar to the one shown over.
To exercise each function manually cycle through the menu
until the option you require is flashing. Now select the function.
The ZVR-530 will exercise the function until you select
FINISH. To change the speed, highlight it in the normal way
and then select it. You can now step through the speed range
of 1-32. When the speed reaches 32, it will loop back to one at
the next step. Before the ZVR-530 can be connected to a
ZoneVu controller, some basic network configuration needs to
be carried out. The simplest way to do this is on the bench
with a monitor connected to the video output of the ZVR-530.
SETTING THE ADDRESS
The valid address range for the ZVR-530 is 1 to 256. To set
the address first highlight and select the Address option in the
Installation Menu. Next, press the button once to advance
the address by one count. To advance the address more
quickly press and hold the button down, after 3 seconds the
address
the address will begin to increment automatically. When the
address reaches 256, it will loop back to one. To stop the
address incrementing release the button. When the address
you want to set is displayed, hold down the button for one
second before releasing it. The new address for the receiver is
now set.
NETWORK SETTINGS
The Network Settings of the ZVR-530 can be configured to
interface to different types of data transmission network. Both
the network type and BAUD Rate can be altered here.
Navigate the menu as previously to select and configure each
setting. The MODE can be set to either RS485, which requires
a single half-duplex data link or to RS422, which requires a
single half-duplex,data link,but with a separate transmit and
receive channel. The Baud rate can be manually set to either
9600, 19200 or 38400 Baud. Alternatively, the Baud rate can
be set to auto for Meyertech equipment, which supports auto
selection. The ZVR-530 incorporates on-board Termination to
terminate the data line when the network is daisy chained or a
single receiver is connected to a driver.
INSTALLATION MENU
Auto Test
Test Facilities
Address
Network Settings
Factory Settings
FINISH
TEST FACILITIES
Pan
Tilt
Zoom
Focus
FINISH
TEST DIRECTION
Pan Left
Pan right
Speed
FINISH
INSTALLATION MENU
Auto Test
Test Facilities
Address
Network Settings
Factory Settings
FINISH
NETWORK SETTINGS
Mode
Baud Rate
Termination
FINISH