manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MG
  6. •
  7. I/O System
  8. •
  9. MG R3-DA16 User manual

MG R3-DA16 User manual

Other MG I/O System manuals

MG R7I4DECT-1-DC32A User manual

MG

MG R7I4DECT-1-DC32A User manual

MG Mini-M M2PDU User manual

MG

MG Mini-M M2PDU User manual

MG R6N-SV2 User manual

MG

MG R6N-SV2 User manual

MG M6DYV User manual

MG

MG M6DYV User manual

MG Devicenet R7F4HD-DA32A User manual

MG

MG Devicenet R7F4HD-DA32A User manual

MG DLC E2 Series User manual

MG

MG DLC E2 Series User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

MG R7G4FML3-6-DC16A User manual

MG

MG R7G4FML3-6-DC16A User manual

MG DLS-M1 User manual

MG

MG DLS-M1 User manual

MG R30BS User manual

MG

MG R30BS User manual

MG Mini-M M2VV User manual

MG

MG Mini-M M2VV User manual

MG R7F4DC-DC16B-H User manual

MG

MG R7F4DC-DC16B-H User manual

MG R8-DCT8B2 User manual

MG

MG R8-DCT8B2 User manual

MG R6N-SS2 User manual

MG

MG R6N-SS2 User manual

MG DS-824 User manual

MG

MG DS-824 User manual

MG R7F4HC-DA32-K User manual

MG

MG R7F4HC-DA32-K User manual

MG R1M-GH User manual

MG

MG R1M-GH User manual

MG R3Y-MS8 User manual

MG

MG R3Y-MS8 User manual

MG R6D-SV2 User manual

MG

MG R6D-SV2 User manual

MG R8-DAT8B2 User manual

MG

MG R8-DAT8B2 User manual

MG R7G4HML-6-SVF8N User manual

MG

MG R7G4HML-6-SVF8N User manual

MG Devicenet R7F4DD-DA16B-H User manual

MG

MG Devicenet R7F4DD-DA16B-H User manual

MG R7E-MS4 User manual

MG

MG R7E-MS4 User manual

MG R7F4HEIP-DA16A User manual

MG

MG R7F4HEIP-DA16A User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

M-system R7D-YV2A instruction manual

M-system

M-system R7D-YV2A instruction manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EM-8375 Rev.6 P. 1 / 3
INSTRUCTION MANUAL
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
DISCRETE INPUT MODULE
(Di 16 points; with excitation supply) MODEL R3-DA16
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Discrete input module.........................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-DA16
EM-8375 Rev.6 P. 2 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
COMPONENT IDENTIFICATION
RUN LED
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ERR LED
Input Status Indicator LEDs
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
■FRONT VIEW ■SIDE VIEW
SW3
ON
4
3
2
1
Functions
Exc.
Monitor
Read
Rate
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with excitation abnormality;
Green in normal operating conditions.
Input status indicator: Red LED; turns on with the input
ON.
■SIDE DIP SW
(*) Factory setting
• Excitation Monitor: SW3-1
SW EXCITATION MONITOR
WITH (*)WITHOUT
SW3-1 OFF ON
• Read Rate: SW3-2, 3-3, 3-4
SW READ RATE (≤ msec.)
10 (*)1 5 20 50 70 100 200
SW3-2 OFF ON OFF ON OFF ON OFF ON
SW3-3 OFF OFF ON ON OFF OFF ON ON
SW3-4 OFF OFF OFF OFF ON ON ON ON
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29)
POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
R3-DA16
EM-8375 Rev.6 P. 3 / 3
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
■CONNECTION DIAGRAM
BUS CONNECTOR
INTERNAL POWER
* For dual redundant communication.
**DO NOT connect to the terminals 9 or 19.
1
18
9
19
Di 1
Di 16
0V
10
20
17
Di 15
16
Di 14
15
Di 13
14
Di 12
13
Di 11
12
Di 10
11
Di 9
8
Di 8
7
Di 7
6
Di 6
5
Di 5
4
Di 4
3
Di 3
2
Di 2
**
INTERNAL BUS A
INTERNAL BUS B*
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.5 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)
FUNCTIONS
■EXCITATION MONITOR
Enabled/disabled with DIP switch setting.
• Excitation Monitor ON
The input is held at the last status when the loss of exci-
tation is detected.
• Excitation Monitor OFF
All input signals are turned off when the loss of excitation
is detected.