Microlink ML-891X Series User manual

Infrared High Speed Dome Camera
(Fourth-generation / IV)
Operating manual
8891X series
Version: V2.0
ML-

Infrared Intelligent High Speed Dome Camera Operating Manual
copyright statement
This copyright belongs to our company. Without permission,any units or individuals shall not in any form or
any means to copy or plagiarize part or the whole of the book content.
Our company follows the strategy of sustainable development. Therefore, the company keeps the right to
modify and improve any products described in this specification under the condition of the no notice in advance .
Safety Caution
1. Before using the camera, please read the attached manual carefully to ensure the correct operation.
2. Wall installation power supply box is with dangerous high voltage,and there is no any replaceable parts,
Laypeople please don't open shielding cover. When wiring, must abide by the electrical safety standards,
please don't choose other power adapter to supply electricity to the camera.
3.The camera video signal cable and RS-485 wiring mouth of control line used ceramic gas discharge tube,
TVS tube instant discharge lightning technology, which can prevent the lightning under 500 W power, surge
and other kinds of pulse of high voltage to damage the interior of the camera.
4.In order to protect the camera not to be damaged by lightning stroke, please use marked the ground wire
ports of preventing lightning plate to access the earth. If no, lightning protection performance will be greatly
reduced.
5.The interior of the camera has high precision structural element, please transport properly.Please do not
leave the camera on the unstable desk or scaffolds to test, insure installation is firm before operation.
6. The camera video signal cable and RS485 control line must be far from high voltage lines as possible, to
avoid touch lines.
7. no matter not in use or be in use,prohibit putting the camera aiming at the sun or other high light objects.
If no, it will cause permanent damage of the CCD in camera interior.
8.When the camera malfunction,with reference to the manual to find fault, if can not find out the fault cause ,
contact professional maintenance persons to maintain. About relevant maintenance work, that must be
maintained by maintenance persons who authorized by our company.
1

Infrared Intelligent High Speed Dome Camera Operating Manual
Contents
1.Installation and debugging of infrared high speed dome camera
1 .1.Infrared high-speed component name
1.2.Istalling hole dimension figure
1. 3.Installation and debugging method
2.Infrared high-speed dome camera setting and operation
2.1.Technology parameter table
2.2.Common functions glossary
2.3.Address, protocol, baud rate setting
2.4.Address dip table
2.5. Control equipment
2.6. Boot initialization
2.7. Basic operation
3.AUTOMATIC OPERATION SETTING > menu operation <
3.1.< PRESET POINT >setting
3.2.< LEFT-RIGHT SCAN > setting
3.3.< CRUISE SCAN> setting
3.4.< PATTERN SCAN> setting
3.5.< TIME ACTION > setting
3.6.< WAIT ACTION > setting
3.7.< PANTILT SETTING > setting
4. <CAMERA SETTING>menu operation
4.1.< LENS PARAMETERS > setting
4.2.< EXPOSUREMODE > setting
4.3.< WHITE BALANCE > setting
4.4.< BACKLIGHT MODE > setting
4.5.< PRIVACY MASK > setting
5. <DISPLAY SETTING>menu
6. <SYSTEM SETTING>menu
7.<ALARM SETTING> menu operating
8. <IR LED SETTING> menu operation
9. Simple troubleshooting table
3
3
3
4
5
5
5
6
7
8
9
9
10
11
12
12
13
14
14
15
14
16
16
17
17
18
18
19
21
21
22
2

Infrared Intelligent High Speed Dome Camera Operating Manual
3
1.Installation and debugging of Infrared High Speed Dome Camera
1.1.Infrared high-speed component name
1.2.Installing hole size figure
Whole set size (mm) Installing hole size (mm)

Infrared Intelligent High Speed Dome Camera Operating Manual
4
1.3. Installation and debugging
1.3.1、Take out the main dome, wall bracket, wall boxing and other components.
1.3.2、Paste the wall boxing to the wall, according to the wall boxing size to drill corresponding hole, then install
the expansion bolts.
1.3.34、Hang the wall bracket on the rotation door.
1.3.4、Plug the cable row into the socket signed "TO DOME" on the right of prevent lighting plate.
1.3.5、penetrate the video cable and 485 controls thread from waterproof screw, and contact to the corresponding
outlet signed "OUTPUT LINE" on the left of prevent lighting plate.
1.3.6、If the distance between dome and the control equipment more than 500M, Push the eight Matching
resistance to “ON” on the DIP switch board SW1 .
1.3.8、Finally, tighten the two mounting screws. Access to 220V AC power supply must pay attention to color
-coded. (Blue and brown zero line and FireWire, yellow is earth wire)
Lighting protection board lines connection
program input

Infrared Intelligent High Speed Dome Camera Operating Manual
5
2、infrared high-speed dome camera setting and operation
2.1.technology parameter table
2.2.Common Functions Glossary
Preset setup:Save some locations that need to be usually monitored,so that can find these locations easily.
Call preset:To run the machine quickly and accurately to a pre-stored location, or execute a specify function.
Left-right scan setup:Set the machine scan back and forth between two points in a certain area. Also
known as A-B Scan.
Cruise setup:Set the machine scan between some preset points, and each preset dwell time between the
points can be set freely.
Pattern Setup:record the scanned line and store it into the machine, easy to play back or run the line at
any time.
Time action:Set the machine to run a certain function at a specific time.
Wait action:After a period of time without any operation, the ball automatically run to the specified preset
point guard, or run a preset function.
Alarm Linkage:When an alarm signal is input, the machine immediately execute pre-configured functions,
and can be linked to other output devices.
Power Supply
Video Output
Communication
Dome Address
Communication Protocol
Baud Rate
Horizontal Rotation Speed
Horizontal Rotation Range
Vertical Rotation Speed
Vertical Rotation Range
Manual Control Speed
One Machine Set
Infrared light(Spec x pcs)
IR Distance
Preset Points
A-B Scan Speed
Cruise scanning
Pattern scanning
Idle Running
Timing of operation
Privacy protection
Password protection
Information Display
Alarm Linkage
Working Temperature/ Humidity
Automatic thermostat indicator
Waterproof
Dimension
Net Weight
AC220V/50Hz or AC110V/60Hz
1.0V p-p 75Ω
RS485
1-255(Support software rewriting address)
Pelco-D/Pelco-P / SANTACHI 650 / FACTORY
2400/4800/9600/19200 bps
220º/s (1-64级变)
360º unlimited
90º/s
0-90º
200º/S
Compatible with SONY,HITACHI,SAMSUNG,LG,SANYO.CNB etc
Φ5 IR LEDs 108pcs / Array LEDs 10pcs
100-120m
220 points
4 groups(1-64 grade speed available)
4 groups(at most 32 preset points each group)
4 groups(at most 100 continuous action each group)
After setting idle 5-255S,it scans automatically
4 groups(can operate at any setted time the whole day)
Can be set to 8 protected areas
Can be set to 6 numbers password
Date,time positon,temperature,etc
Support 4ways output,2ways input, colse/open optional
-40℃—+60℃, ≤95% (no condensation)
<-5℃ Heating, >48 Cooling℃
IP65
360(L)×318(W)×180(H)mm
5.1kg

Infrared Intelligent High Speed Dome Camera Operating Manual
6
Power-off memory:When the machine restart after power failure, it will automatically revert to the last
stop position or the last working state.
High zoom low speed: with manual zoom lens value increases,the manual control speed in proportion
to slow down.
Far and Near conversion:In night mode, far/near-infrared light automatically converted according to
the lens multiplier. When the lens multiplier nearly 13 times, the near lights
on. When above 13 times, the far light on.
Day/Night conversion:the machine identify the current ambient light through photosensitive Resistance,
turn on the infrared lights, and convert black and white images automatically.
Automatic Focus:If the product is set to auto-focus mode, When the user control PTZ, the camera always
follow the auto-focus.
2.3.Address, protocol, baud rate setting
After machine installed, be sure the ball machine set DIP switch address code, protocol, baud rate is fully
consistent with the control equipment. Our High speed Demo camera default address is 1, communication
Protocol Pelco-D, Baud Rate 2400bps. Corresponding DIP switch status is as follows:
If you need to change the protocol setting, please refer to the following diagram to set the DIP:
If you need to change the baud rate setting, please refer to the following diagram to set the DIP:
Camera Address Setup
Empty
Empty
Empty
Baud Rate setup
Communication Protocol Setup

Infrared Intelligent High Speed Dome Camera Operating Manual
7
2.4.Address DIP table(1 means ON,0 means OFF)
Binary code Address Binary code Binary code Address Binary code Binary code Address

Infrared Intelligent High Speed Dome Camera Operating Manual
8
2.5 Control equipment
According to users’ need, below are the equipments normally used:
Control borad PC(Video capture card)
DVR tester(specially for project)
Binary code Address Binary code Address Binary code Address Binary code Address
Operation instructions: As the specific operation ways are different for Variety of controlling
equipments, please refer to the referring manual. IR high speed dome camera advise all users collocate
special controlling board, more using convenient. All the operation ways of this manual are taking
controlling board operating as example.
1(Software
modify)

Infrared Intelligent High Speed Dome Camera Operating Manual
9
2.6.Boot initialization
Connect the video line and 485 controlling line to the monitor or DVR, ensuring that the connection is right then
catch 220V power to the power case of camera.
The ir high speed dome camera outpour signal to the screen and start searching varity of collocating information,
about after 10 seconds, the screen will show the list of the camera’s initialization, as picture 1.
At the mean while, the PTZ starts check up, down, left and right, after checking will show” system initialization
success”. Then it will standby(picture 2) or get back to the status as the last time off power.
When at standby status, it will show varieties of operating stuffs’ name on the left-up the screen, such as:
camera name, preset name, A to B scanning name, cruise scanning name and pattern scanning name.Current
date,time,surveillance direction,ptz location,lens multiple,temperature and so on. If no need to show,p.l.s
enter the menu<showing information setting> and set:close.
2.7. Basic operation
Frame: select surveillance area.user can operate the rocker up,down,left,right to move the holder to find the
surveillance direction. By operating the keyboard ”zoom+” or “zoom-“,zoom the image. Press”focus+” or
“focus-“,to adjust lens focus manually.
Set presets:We can set the often monitored location as presets and save in the camera,use number for
saving,the camera’s maximum quantity of preset is 220. When it shows preset setting successfully,the screen
will point out “preset saved”. Showed by picture 3:
Picture1 checking
information when start up:
Picture 2 standby status:

Call presets:run the preseted presets in advance quickly and precisely. And for easy operation, we can
call the presets to realize some common use functions. As these calling commands will be occupied by speedy
functions, so cant be called solely.
Common function calling preset comparing table:
3.< AUTOMATIC OPERATION SETTING >menu operation
Attention:the manual explanation sequences are based on the practicability of camera
function,not based on the menu. Please choose the sections you need.
Enter camera main menu:
Under the standby status,call”95”,enter the camera main menu. There are 6 groups. As picture 4:
function
Start 1-4 group cruise scan
Open main menu
Start the first group L-R scan
Oblige transerring day-night mode(automatical mode,
night mode,day mode)
Start 1-4 group pattern scan
Call preset
71、72、73、74
95 or 64
98
99
101、102、103、104
explanation
Start cruise scan
Open camera main menu
Day and night mode
transfer
Playback pattern scan
Infrared Intelligent High Speed Dome Camera Operating Manual
10
Picture 3 set preset:
Picture 4 open main menu:

Infrared Intelligent High Speed Dome Camera Operating Manual
11
Apply explanation:
1.After entering the menu, cursor flicker position is the current chosen menu item, operate the joystick up
and down can move the cursor to choose other items. Press “iris+” or “zoom+”, enter submenu, press
“iris-” or “zoom-“,back to the former menu. If no operation in 60 seconds, then it will quit the menu.
2.Menu back will with”>>”,means with submenu,”…”means call the command.
3.1.PRESET> setting
Move the cursor to <AUTOMATICALLY OPERATE SETTING>, press”iris+” then enter the submenu. Showed
as picture 5:
Move the cursor to “Presets Setup”, press “Iris +”to enter into the submenu. See Picture 6.
Detail Operation:
1.Preset Number: Press “Iris +” to enter and select the preset number, up or down the joystick to select
1-220 preset point number
2. Title: Press “Iris +” to enter and edit the title, up or down the joysticks to choose numbers,letters, or
characters. Left or right the joystick to move the location or correct the letters. Editing is completed
by "Iris +" to save and return;
3.Set new preset:Press the "Iris +" to enter into setting preset points state, Pan/Tilt/Zoom to select a desired
position, press the "Iris +" to determine the location, the system will prompt "edit preset
title". if no need the title, press "iris +" to exit and return;
4.Show Next preset:When you press "Iris +", the camera will immediately run to the next preset position,
then you can modify the preset point. If the next preset point is not set, it will prompt
"the preset is not set";
5.Delete Current Preset Point: press "Iris +" to delete the current preset point
<
Picture 5 auto run:
Picture 6 preset
point setting:

Application explain:
1. Setting preset point also can be in standby state, just change to set preset point mode, then type setting
preset point Numbers, confirm, the system can display "preset point has save".
2. About Numbers and name of the preset is different . Numbers is the only identity number for camera
storage , name is to set by the user.
3.2.< LEFT-RIGHT SCAN> setting
Move the cursor to the < LEFT-RIGHT SCAN >, press " IRIS +" to enter submenu. See 7:
Operation:
1.LEFT-RIGHT SCAN Number: press“IRIS +”to enter and choose scan nubmer,control lever up and down
to choose scan number group1-4.
2.Title setting: press“IRIS +”to edit title, control lever up and down to choose number,letter and other
characters.left and right to edit position and modify characters,press“IRIS +”to save after
edit then return.
3.Set start: press“IRIS +”to set scan start, move PTZ to choose the start on the left, press“IRIS +”again to
confirm and return.
4. Set stop: press“IRIS +”to set scan stop, move PTZ to choose the stop on the right, press“IRIS +”again to
confirm and return.
5.Set scan speed: press“IRIS +”to set scan speed,control lever up and down to increase and decrease
speed number (1-64)
6.Run continousely: press“IRIS +”to run current LEFT-RIGHT SCAN.
7.Delete current: press“IRIS +”to delete current LEFT-RIGHT SCAN.Quick command of LEFT-RIGHT
SCAN: using No.98 preset point, (click “preset” botton, then input number “98”, click
”Enter”), the high speed dome will scan with the speed we have presetted
3.3.<CRUISE SCAN> setting
Move the cursor to the <CRUISE SCAN >, press " IRIS +" to enter submenu. See Picture 8:
Picture
Infrared Intelligent High Speed Dome Camera Operating Manual
12
Picture7<LEFT-RIGHT
SCAN> setup:
Picture8 < CRUISE
SCAN> setting:

Detail Operation:
1.CRUISE SCAN Number: press“IRIS +”to enter and choose scan nubmer,control lever up and down
to choose scan number group1-4.
2.Title setting: press“IRIS +”to edit title, control lever up and down to choose number,letter and other
characters.left and right to edit position and modify characters,press“IRIS +”to save after
edit then return.
3.DWELL TIME: press“IRIS +”to set the dwell time of every preset point.the default is 5 seconds.control
lever up and down to choose the number of second(1-255), press“IRIS +”to save after edit
then return.
4.EDIT CRUISE: press“IRIS +”to enter edit cruise interface.move the cursor to the right“0000”set preset
point number 1, control lever up and down to choose one preset point of the number (1-220),
move to the right and then selecting“005”set dwell time of the first preset point. control
lever up and down to choose second(1-255),every group can up to set 32 preset point,same
with other preset points setting.press“IRIS +”to save after edit then return. Picture 9 shows:
5.SHOW ONLY ONCE: press“IRIS +”to start current cruise scan once. the demonstration is over then back
automatically.
6.RUN CONTINUOUSLY: press“IRIS +”to run current cruise scan.
7.DELETE CONTINUOUSLY: delete the setted current cruise scan.Quick command of CRUISE SCAN:
using No.71-74 preset point to run the group(1-4) cruise scan respectively
in the standby mode.
3.4. <PATTERN SCAN> setting
Move the cursor to the <PATTERN SCAN >, press " IRIS +" to enter submenu. See Picture 10:
Application Note:
1.List in the order of from left to right, a line move to the next line when it is end;
2. A group cruise can up to 32 preset points position, each position of the preset point can not follow the
order of present
Infrared Intelligent High Speed Dome Camera Operating Manual
13
Picture10 EDIT PATTERN< >
setting:
Picture9 EDIT CRUISE
:
< >
setting

Detail Operation:
1.PATTERN SCAN Number: press“IRIS +”to enter and choose scan nubmer,control lever up and down to
choose scan number group1-4.
2.Title setting: press“IRIS +”to edit title, control lever up and down to choose number, letter and other
characters.left and right to edit position and modify characters, press“IRIS +”to save after
edit then return.
3. Record NEW Pattern: Press "Iris +" to enter the pattern scan recording state, once again press the "Iris +"
to start recording the scan path, then control lever up, down, left, right, zoom and
other command and control high speed dome camera freely recording a track, each
track can store up to 100 action command, recording is complete press the "Iris +" to
confirm and return;
4.SHOW ONLY ONCE: press“IRIS +”to replay current pattern scan once. the demonstration is over then
back automatically.
5.RUN CONTINUOUSLY: press“IRIS +”to playback current recording pattern scan.
6.DELETE CONTINUOUSLY: delete the setted current pattern scan.
Quick command of PATTERN SCAN: using No101-104 preset point to run the group(1-4) pattern scan
respectively in the standby mode.
3.5.< TIME ACTION > setting
move the cursor to<TIME ACTION>,click “IRIS+” to enter submenu. The monitor shows as 11:
Detail operations:
1.Time number:click “IRIS+” to choose time number,move joystick up or down to choose 1-4 number;
2.Start-time:click“IRIS+”to set start- time. Dome camera can set time in 24 hours. Move joystick up or down
to set 00-23 hour number, and move joystick right to minute setting. Then move up or down to
set 00-59 minute number. Click “IRIS +”to save the setting and return.
3.End-time:click“IRIS+”to set end-time. Move joystick up or down to set 00-23 hour number, and move
joystick right to minute setting. Then move up or down to set 00-59 minute number. Click “IRIS
+”to save the setting and return.;
4.Run action:click“IRIS+”to run one action. The actions include: cruise number 1-4、left- right soan number
1-4、pattern number 1-4、1-220 preset and“close”。Move joystick up or down to choose one
of them.“close”means don’t run any actions. click “IRIS+” to save and return;
3.6.WAIT ACTION > setting
Move the cursor to <WAIT ACTION>,click “IRIS+” to enter submenu. The monitor shows as 12:
Picture
<
Picture
Picture11<TIME ACTION>
setting:
Infrared Intelligent High Speed Dome Camera Operating Manual
14
Auto-running instructions:
1.the priority of auto-running(from high to low) is:1 user temporary operation、2alarm action、3time
action、4wait action;
example:in standby mode if set “wait action”, dome camera runs “wait action”; if also set “time action”,
then dome camera runs “time action” in priority; if also received alarm signals, then dome
camera runs “alarm action” in priority; if user operates, then dome camera run user’order;

Detail
<
Picture
operations:
1.Wait time:click “IRIS+” to enter and set wait time,move joystick up or down to set wait time from 1 to
255seconds,default time is 5s. for example it is 10s, then dome camera will run action if no
operation in 10s.
2.Run action:click “IRIS+” to run one action. The actions include: cruise number 1-4、left- right soan
number 1-4、pattern number 1-4、1-220 preset and“close”。Move joystick up or down to
choose one of them. “close”means don’t run any actions. click “IRIS+” to save and return;
3.7.PANTILT SETTING > setting
Move the cursor to <PAN TILT SETTING>,click “IRIS+” to enter submenu. The monitor shows as 13:
Detail operations:
1.Auto-flip:click “IRIS+” to enter,move joystick up or down to choose open or close. If set “open”,dome
camera will auto-flip 180 degree horizontally when pan tilt run to 90 degree vertically.
2.Auto focus mode:click “IRIS+” to enter,move joystick up or down to choose iris 、focus、close、all.
For example choose “iris”, then lens focus will not change when pan tilt move. And
the lens will auto-focus when operate iris. If choose “all”, then the lens will auto-focus
when any operations;
3.Auto change speed:click “IRIS+” set whether the speed matches lens zoom. The bigger the zoon is,
the lower the speed is;
4.Manual control speed: click “IRIS+” to enter. Move joystick up or down to set 1-128 level. But must set
<auto change speed> “close”, then this set works. Click “IRIS+” to save and return.
5.Setting north: dome camera can show east、south、west、north、northeast、southeast、northwest、
southwest. When the dome camera installation finished, the direction is incorrect, so
should set right direction of north. Click “IRIS+” to set and move joystick left or right ti
find the right north. Click “IRIS+” to save and return.
6.Go to zero position: click “IRIS+” to make pan tilt go to zero position.
Infrared Intelligent High Speed Dome Camera Operating Manual
15
Picture13<PANTILT>
setting:
Picture 12<WAIT
ACTION>setting:

Picture15 LENS
PARAMETER setting:
<
>
Infrared Intelligent High Speed Dome Camera Operating Manual
16
4、<CAMERA SETTING>menu operation
Enter<CAMERA SETTING>menu
instructions:about the camera function inside,different camera have different functions,
only small difference。take SONY EX480CP for example below 。
type the number in standby model “preview+95+enter”,move the cursor to<CAMERA SETTING>,click “iris+”
to enter submenu. the monitor show as Picture 14.
<
<
4.1.LENS PARAMETER> setting
Move the cursor to<LENS PARAMETER>,click “IRIS+”to enter the submenu。Show as Picture15:
Detail operations:
1.Zooming speed :click“IRIS+” to set zooming speed . Move the joystick up or down to choose high or
low speed. Click “IRIS-” to save and return
2.Digital zoom:click“IRIS+” to set digital zoom . Move the joystick up or down to open or close digital
zoom function;
3.Focus limit:click“IRIS+”to set focus distance. Move the joystick up or down to set proper focus distance
based on the target distance;
4.Picture freeze:click“IRIS+”to set picture freeze. if the setting is “open”, the scanning process from
one point to another point will be frozen when you preview. Click “IRIS+” to save and
return.
4.2.EXPOSURE MODE> setting
Move the cursor to<EXPOSURE MODE>,click“IRIS+”to enter submenu, show as Picture16:
Picture 14<CAMERA
SETTING>setting:

Details operation:
1.Exposure mode:click“IRIS+”to enter setting,move the joystick up or down to choose AUTO、MANUAL 、
AGC LEVEL、SHUTTER、IRIS. in “AUTO” mode ,IRIS LEVEL、SHUTTER SPEED、
AGC LEVEL、BRIGHT LEVEL below can not be changed. but in “MANUAL” mode ,
they can be changed on request;
2.Iris level:when “exposure mode”is set as “IRIS”mode,then set lens F level(the higher, the darker the
image is
3.Shutter speed:when“exposure mode”is set as“shutter”mode,then set1/1-1/10000 shutter(the higher,
the darker the image is) ;
4.AGC level:when“exposure mode”is set as“MANUAL”mode,then set0-28db AGC level(the higher, the
brighter the image is) ;
5.Bright level:when“exposure mode”is set as “AGC LEVEL” mode,then set 0-31 brighter level (the higher,
the brighter the image is) ;
6.Digi-slow shutter:set digital shutter to open or close;
7.Day/night mode:make the camera and IR led change day/night mode by force to three modes: auto ,
night and day;
4.3.WHITE BALANCE> setting
Move the cursor to<WHITE BALANCE>,click“IRIS+”to enter the submenu, show as Picture17:
Detail operations:
1.White balance:click“IRIS+”to set,move the joystick up or down to choose auto,outdoor, indoor, auto
tracking, one time aviating, manual mode.When only choose“manual”, “R.gian”
and “G.gain” level below can be changed ;
2.R.gain:when“white balance”is set as“Manual”mode,then set000-255 level of R.gain;
3.G.gain :when“white balance”is set as“Manual”mode,then set000-255 level of G.gain;
4.4.BACKLIGHT MODE> setting
Move the cursor to<BACKLIGHT MODE>,click“IRIS+”to enter submenu. show as Picture18:
) ;
<
<
Infrared Intelligent High Speed Dome Camera Operating Manual
17
Picture17<WHITE
BALANCE>setting:
Picture16<EXPOSURE
MODE>setting:

Operations:
1.Backlight mode:click “IRIS+” to enter ,move the joystick up or down to open or close backlight mode;
4.5.PRIVACY MASK > setting
move the cursor to<PRIVACY>,click“IRIS+” to enter submenu. Show as Picture19:
Detail operations:
1.Masking number:click “IRIS+”to choose masking number. move the joystick up or down to choose
1-8 masking number;
2.Setup new mask:click“IRIS+”to setup new mask. Move the PTZ or zoom to choose the object needed
to cover and be sure the object is in the middle of the monitor,again click“IRIS+”to
set the size of the area. It appears a black rectangular area in the middle. At this
moment moving up means reducing the area vertically and moving down means
increasing. Moving left means reducing the area horizontally and moving right means
increasing. Click “IRIS+” to finish setting and return. show as Picture20-21:
<
Infrared Intelligent High Speed Dome Camera Operating Manual
18
Picture20Choose protection place:
Picture 21set the size:
Picture18<BACKLIGHT
MODE>setting:
Picture19<PRIVACY>
setting:

Infrared Intelligent High Speed Dome Camera Operating Manual
19
Detail operations:
1.Dome name:click“IRIS+”to enter setting,move the joystick up or down to change the display. there
are open、60s、30s、15s、10s、5s、2s、close optional.choosing “close”means not
display.if choose the seconds, it means it will close after the time you choose;The others
have the same setting as above.
Global Settings: click“IRIS+”can to modify all project consistently, click“IRIS+”one time,it change a new
number.
6、SYSTEM SETTING>menu<
Enter<SYSTEM SETTING>menu
type the number in standby mode “preview+95+enter”to enter the main menu. move the cursor to<system
setting>, then click “IRIS+”to enter submenu. Show as 23-24: Picture
Detailed Operating:
1. CHANGE DOME ID: Press ”Iris+” enter the software for CHANGE DOME ID. If the current one is hardware
DIP address, there will be a reminder that “please set it to be 0 for hardware address
first!”, it means 8pcs address DIP need to be moved down on DIP switch board. You
need to input correct camera series no when enter Soft modification address ,then
press ”Iris+”, and next the address DIP twinkled, then you could choose the 1-255
Picture 24Change camera address:
Picture 23 STYSTEM setting:< >
Picture22 DISPLAY
setting:
< >
3.Mask active:click“IRIS+”to enter. Move the joystick to choose “open” or “close” the privacy masking;
4.Show next mask:when click“IRIS+”,the dome will operate to next privacy masking at this moment
you can change this privacy masking. if you don’t setup next privacy masking ,it will
show “this privacy is not set”;
5.Delete current mask:click “IRIS+”to delete current mask;
5、<DISPLAY SETTING>menu
Enter<DISPLAY SETTING>menu
type the number in standby mode“preview+95+enter”to enter the main menu.Move the cursor to<DISPLAY
SETTING>, then click “IRIS+” to enter submenu. Show as Picture 22:
Table of contents
Other Microlink Security Camera manuals