www.mircomgroup.com LT-6155 Rev. 0 Oct 2021
MPS-800(U) Series
Fire Alarm Manual Station
1
Mircom’s MPS-800(U) Series Fire Alarm Manual Stations provide
manual fire alarm activation.
This guide covers these models:
MPS-810 Single Stage, Dual Action, Conventional Manual Station
MPS-810U Single Stage, Dual Action Conventional Manual
Station (US)
MPS-802 Two Stage, Dual Action, Conventional Manual Station
Specifications & Dimensions
Compatible with Mircom Fire Alarm Control Panels
Electrical Rating:1 A at 30 VDC
Dimensions:
139 mm H x 104 mm W x 34 mm D
(5 1/2” H x 4 1/8” W x 1 3/8” D)
Install the manual station
Contents of kit
MPS-810(U): 2 mounting screws, 2 reset keys (black)
MPS-802: 2 mounting screws, 2 reset keys (black), 2 stage two
keys
A. Open
1. Insert the reset key into the reset keyhole and turn it.
2. Pull the cover open.
Figure 1 Front of manual station
Figure 2 Opening the station
Notes
• Environment: Outdoor, wet
• Do not change factory applied finishes.
• Wire as shown so that supervision of connections is
maintained.
• Maximum wire size: 14 AWG
• ADA compliant.
• To be installed per ADA 4.27.1 to 4.27.4 inclusive.
• Wiring must be in accordance with CSA C22.1, Canadian
Electrical Code, Part I, Safety Standard for Electrical
Installations, Section 32 and CAN/ULC-S524, Standard for
Installation of Fire Alarm Systems.
• All manual fire alarm stations shall be installed as per the
specific requirements outlined in the UL/ULC codes, as well
as all other applicable national or local codes. Final
acceptance is subject to the local authority having
jurisdiction.
RESET
KEYHOLE
STAGE TWO
KEYHOLE
(MPS-802 ONLY)
PUSH BAR
PULL
HANDLE
COVER
MOUNTING
PLATE
Canada
25 Interchange Way
Vaughan, ON L4K 5W3
Tel: 1-888-647-2665
U.S.A
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Tel: 1-888-647-2665
MPS-800(U) Series
Fire Alarm Manual Station
www.mircomgroup.com LT-6155 Rev. 0 Oct 2021
2
B. Wire
Note: The maximum wire size is 14 AWG.
1. Strip wires to 10 mm (25/64”) maximum.
2. Push the wire into the terminal.
Note: The terminals have a push-in lock. To remove the wire,
push the terminal in with the screwdriver and pull out the
wire at the same time. see Figure 3.
Figure 3 Removing the wire
3. Wire as shown in Figure 4.
Figure 4 Wiring
C. Mount
Flush mount indoor: Single-gang electrical box.
Flush mount outdoor: Single-gang electrical box with STI-1250
(Shallow Cover with Gasket)
Surface mount indoor: BB-800 backbox with or without STI-1230
(Deep Cover without Gasket)
Surface mount outdoor: BB-800 backbox with STI-3150 (Deep
Cover with Gasket)
Note: Mount the manual station with the Mircom logo on the
bottom.
Figure 5 Back of manual station
Using the manual station
Activate the alarm
1. Push in the push bar.
2. Pull down the pull handle.
A qualified person must reset the station by opening it with the
reset key. See Resetting the manual station below.
Activate the stage two alarm (MPS-802)
• Insert the stage two key into the stage two keyhole, and then
turn the key.
The stage two alarm activates immediately.
Note: The stage two alarm will activate automatically a certain
amount of time after the handle has been pulled if no
action is taken. This time is set in the Fire Alarm Control
Panel.
Reset the manual station
Note: Resetting the station does not cancel the alarm at the
panel.
1. Insert the reset key into the reset keyhole and turn it.
2. Pull the cover open. The switch is now reset.
3. Close and lock the station with the reset key.
4. Reset the Fire Alarm Control Panel to reset the alarm.
TO REMOVE WIRE, PLACE
A SMALL FLATHEAD
SCREWDRIVER INTO THE
GROOVE AND PUSH IN.
AT THE SAME TIME, PULL
THE WIRE OUT OF THE
TERMINAL.
TO NEXT STATION OR
LEAVE IT EMPTY
FROM
PREVIOUS
STATION
TO NEXT KEYSWITCH
OR END OF LINE DEVICE
(MPS-802 ONLY)
í+
+
FROM
PREVIOUS
KEYSWITCH
(MPS-802 ONLY)
+
+
í
íí
MOUNTING
HOLES

This manual suits for next models

3

Popular Fire Alarm manuals by other brands

olympia electronics BSR-100 Series Quick Installation Guide & Generic Design

olympia electronics

olympia electronics BSR-100 Series Quick Installation Guide & Generic Design

Numens 460 Series installation instructions

Numens

Numens 460 Series installation instructions

Global JUNO-NET Operation & maintenance manual

Global

Global JUNO-NET Operation & maintenance manual

Pyro-Chem Kitchen Knight II Technical manual

Pyro-Chem

Pyro-Chem Kitchen Knight II Technical manual

Cooper Notification HS4 Series installation instructions

Cooper Notification

Cooper Notification HS4 Series installation instructions

Simplex 4098 Applications manual

Simplex

Simplex 4098 Applications manual

Siemens FDCW221 Technical manual

Siemens

Siemens FDCW221 Technical manual

Hochiki HCA-2 Installation and operation manual

Hochiki

Hochiki HCA-2 Installation and operation manual

Panasonic EBL512 G3 5000 operating instructions

Panasonic

Panasonic EBL512 G3 5000 operating instructions

Vigilant MX1-Au Service manual

Vigilant

Vigilant MX1-Au Service manual

Global Fire Equipment JUNIOR V3 Operation & maintenance manual

Global Fire Equipment

Global Fire Equipment JUNIOR V3 Operation & maintenance manual

Teknim TFS-1182R installation manual

Teknim

Teknim TFS-1182R installation manual

Notifier NBG-12LA quick start guide

Notifier

Notifier NBG-12LA quick start guide

Siemens FDMH294-R Installation

Siemens

Siemens FDMH294-R Installation

MORLEY-IAS FW9003 Range installation manual

MORLEY-IAS

MORLEY-IAS FW9003 Range installation manual

Ampac 4310-0082 installation guide

Ampac

Ampac 4310-0082 installation guide

Advanced MxPro5 5000 Series product manual

Advanced

Advanced MxPro5 5000 Series product manual

Honeywell NOTIFIER AM-8000 Programming manual

Honeywell

Honeywell NOTIFIER AM-8000 Programming manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.