Installation Precautions
Voltage Selection and Power Connection
Mains power to the XL42 is supplied by means of a standard fused IEC power socket. The XL42 is designed to operate at
nominal mains voltages of 115V and 230V V a.c. at either 50 or 60 Hz, however upon first use (and whenever the mains
supply is changed) the input voltage selector on the rear of the unit must be set to reflect the local power supply. This
information is also printed on the rear of the unit below the mains inlet socket.
This device must be earthed and must use an approved mains fuse. Before connecting to the mains supply, ensure
the fuse fitted is the correct type and rating as indicated on the rear panel, adjacent to the fuse holder and that
the correct mains supply voltage is selected.
Safety Warning
To completely disconnect this equipment from the AC Mains, turn the power switch to the off position. The power
switch shall remain readily operable.
Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as
vases, are placed on the equipment.
For safety reasons the earth lead for this unit should never be disconnected. In the event of ground loop
problems, under no circumstances must the mains earth be removed. Instead, disconnect the signal screen at
one end of the connecting cables.
N.B. This can only be done when the unit is being used within a balanced system.
To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock do not
remove covers. Refer servicing to qualified personnel only.
Attention! Cables
The inputs and outputs are balanced on conventionally wired XLRs (pin 1 screen, pin 2 hot and pin 3 cold). This product
should only be used with high quality, screened twisted pair audio cables, terminated with metal-bodied 3-pin XLR
connectors. Any other cable type or configuration for the audio signals may result in degraded performance due to
electromagnetic interference.
Note that +48V phantom power can only be used with balanced cables.
Electric Fields
Should this product be used in an electromagnetic field that is amplitude modulated by an audio frequency signal (20Hz
to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a frequency corresponding to the
modulation signal may be experienced under extreme conditions (3V/m, 90% modulation).
No permanent damage or degradation of performance will be caused by these conditions.
Do not install this unit in a location subjected to excessive heat, dust or mechanical vibration. Allow for adequate
ventilation around the unit, making sure the unit's vents are not obstructed. To avoid excessive heating of the unit,
avoid mounting the unit directly above power amplifiers or other devices that radiate significant amounts of heat.
Where necessary, use fan-cooled racks.