2
Install with confidence.
Moen has created this useful guide to assist you when installing a Moen®
Vertical Spa. You’ll find detailed guidelines, color-coded piping diagrams
and FAQs for some of the most popular configurations.
For additional information not contained within this general guide, refer
to the Moen Vertical Spa Design Guide (MF2816), contact your Moen
representative, visit moen.com or call Customer Support at 1-800-BUY-MOEN.
ioDIGITAL
™Valve
ioDIGITAL uses a digital valve to control temperature and flow. This valve plugs into a standard 110v
power outlet that can be located in a linen closet, under the tub—up to 30 feet from the bathroom —
for easier installation and retrofit flexibility. The innovative design can also store up to 4 temperature
and spray outlet flow combinations into memory with instant, one-touch activation.
1. Is a digital valve easier or more difficult to install
compared to a regular thermostatic valve?
•AllioDIGITALvalvesincludepush-fitconnectors
that work easily and quickly with traditional
plumbing supply tubes (PEX, CPVC and copper).
• 
ioDIGITAL vertical spa systems require fewer
trim components (handles/knobs) to install.
•Adjustingthemaximumtemperatureallowableis
easily done on ioDIGITAL valves via a dial control.
Such calibration of standard thermostatic
cartridges is a more time-consuming process.
2. How does the life expectancy of the digital valve
compare with other thermostatic valves?
• 
The Moen ioDIGITAL system is certified to
cUPC with applicable standards ASSE 1016 and
ASME A112.18.1M/CSA B125.1 (shower valves),
and UL1951.
• 
All of the ioDIGITAL system components are
backed by a five-year limited warranty, and the
finishes and mechanical components feature a
Limited Lifetime Warranty.
3. How many spray outlets can be used in a
digital vertical spa?
 •TheMoenverticalspafeaturesfoursprayoutlets
and a maximum flow rate of approximately 17.5 gpm
at 45 psi flowing—configuration examples to follow.
•
Always cap unused outlets.
4. Do you need a larger hot water tank? What are
the drainage requirements?
•
The vertical spa will work with standard hot
water tanks and typical drainage.
 •Ifyourshowerlayoutincludestwoverticalspa
ioDIGITAL spa valves, an 80-gallon or larger hot
water tank is recommended. The vertical spa
system works with plumbing and drainage that
are common to most households.
5. What is the minimum water pressure needed for
a digital valve?
•
20 psi, which is a code requirement.
 •WiththeMoenioDIGITALverticalspa,apressure
of at least 40 psi is recommended for optimal
performance and satisfaction.
EXACTTEMP®3/4"
THERMOSTATIC CONTROL
ioDIGITAL 3/4"
VERTICAL SPA VALVE MOENTROL®WITH BUILT-IN
3-FUNCTION TRANSFER VALVE
3
6. Will the digital valves work with existing
showerheads, hand showers and body sprays?
Yes, the ioDIGITAL system works with all Moen
fixtures.
7. Will the valve fit within a regular 2" x 4"
framed wall?
Yes.
8. Does the valve need to have ventilation?
No. The valve should be mounted in an interior
wall to eliminate extreme temperature conditions.
It should not be installed in locations that exceed
the range of 40°F –104°F.
9. Do I have to plug the valve in, and is an
electrician required for the installation?
Yes, the valve needs to be plugged into a 110v AC
supply on a GFCI circuit. A certified electrician
should install the initial GFCI outlet.
10. Is the valve compatible with PEX, copper and
CPVC?
The push-fit connectors supplied with ioDIGITAL
valves work well with each of these pipes—
seals on the outside diameter.
11. Do you need an access panel for the valve?
•
Yes. A minimum of 14-1/2" x 30" access
panel is required.
•Thevalvemustbeinstalledwiththefrontfacing
the access panel.
12. Can the controller be installed outside the shower?
Yes. A 30-foot data cable connects the valve
and controller, which gives you the ability to
mount the controller at a convenient location
within the home.
13. How does the controller mount to the wall?
The controller mounts simply with two screws
in a standard 2" x 4" wall. Refer to instruction
sheets INS1663 and INS1666.
14. What are the inlet sizes?
3/4".
15. What are the outlet sizes?
1/2".
16. Are water hammer arresters required?
Water hammer arresters are highly
recommended, similar to other high-
water-flowing home appliances.
17. Are stops required?
Yes, stops upstream of the water hammer
arresters to allow for servicing.
Note: Outlets A and B constitute
one valve body. Outlets C and D
constitute another valve body.
High-flow devices (e.g., tub spouts,
multiple body sprays) should be split
up between the A/B and C/D outlet
pairs. For example, if a tub spout is
connected to outlet B, 3 body sprays
should connect to C or D, not A.
ExactTemp®3/4"
Thermostatic Control
Moentrol®with Built-In
3-Function Transfer Valve
The ExactTemp Thermostatic Control uses a
mechanical system within the valve body to
automaticallyadjusthotandcoldwaterdelivery
and maintain consistent water temperature. The
Moentrol valve lets users turn their spa on and off
without changing the temperature position, so they
can easily return to their last temperature setting.
Q: If the hot and cold inlets are mistakenly
reversed, is the ExactTemp 3/4" cartridge
reversible?
A: NO.Hot and cold inlets will have to be
corrected for proper installation.
Q: Does the ExactTemp 3/4" cartridge need to be
removed when soldering the valve?
A: NO.Neither the temperature nor flow cartridge
needs to be removed. The cartridges will not
overheat as a result of normal soldering process.
Q: Can components (body sprays, hand showers,
etc.) be installed on a different wall than the
transfer valve?
A: YES, but it is important to follow two basic
principles to maximize performance: 1) minimize
the distance between components and the
transfer valve; 2) minimize the number of turns
in the plumbing lines from the transfer valve to
the component.
Q: Do I need to use 3/4" tubing between
components?
A: It is recommended that you install 3/4" tubing
between thermostatic and flow valves, and
1/2" pipe everywhere else. If 3/4" inlets are
available, that is preferred. However, 1/2" will
not diminish performance.
ABCD
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
4
One-Wall ioDIGITAL™3/4"
ioDIGITAL™3/4" de pulgada en una pared
GFCI
back of valve
faces into
shower
DCBA
78"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
60"
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
eZ
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
Always cap
unused outlets.
Siempre cubra las
conexiones sin usar.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g.,
tub spouts, multiple body
sprays) should be split up
between the A/B and C/D
outlet pairs. For example,
if a tub spout is connected
to outlet B, 3 body sprays
should connect to C or D,
not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre
los pares de entradas A/B
y C/D.
Porejemplo,sila
tina esta conectada a la
entrada B, conecte el spa
vertical a la entrada C o
D, no a la entrada A.
Water inlets are opposite of how
typical plumbing is installed.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
78"
48"
40"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
16"
Arrow on volume control
valve should always point
in direction of flow.
La flecha en la válvula
de control de volumen
deberá siempre apuntaren
ladireccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera
dehidromasajevertical.
One-Wall ExactTemp®3/4"
ExactTemp®3/4" de pulgada en una pared
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
5
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
e
Z
got orig. file, but need
orig. graphics. mary
ann?
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
6
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
One-Wall ioDIGITAL™3/4" with tub spout
ioDIGITAL™3/4" de pulgada en una pared
con pico de bañera
GFCI
back of valve
faces into
shower
DCBA
78"
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
eZ
60"
54"
42"
30"
Water inlets are opposite of how
typical plumbing is installed.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.Porejemplo,silatina
esta
conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
78"
48"
40"
HOT WATER INLET
Entrada de agua caliente COLD WATER INLET
Entrada de agua fría
From Flow
Valve
To Shower
Head
16"
When using a tub spout
with a volume control valve,
plumb the flow valve outlet
to the twin ell front vertical
inlet. Plumb the twin ell
rear vertical outlet to the
showerhead. Plumb the twin
ell front horizontal outlet
to the tub spout.
Cuando utilice un pico de
bañera con una válvula de
control de volumen, conecte
la salida de la válvula de
controldeflujoalaentrada
vertical frontal del codo
doble. Conecte la salida
vertical trasera del codo
doble al cabezal de la ducha.
Conecte la salida horizontal
frontal el codo doble al pico
de la bañera.
Always cap the showerhead
port when using the
ExactTemp 3/4" valve in a
vertical spa configuration
that includes a tub spout.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera
dehidromasajevertical.
Arrow on volume control
valve should always point
in direction of flow.
La flecha en la válvula de
control de volumen deberá
siempre apuntar en la dir
eccióndelflujo.
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
One-Wall ExactTemp®3/4" with tub spout
ExactTemp®3/4" de pulgada en una pared
con pico de bañera
7
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
e
Z
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
8
One-Wall ioDIGITAL™3/4"
ioDIGITAL™3/4" de pulgada en una pared
GFCI
back of valve
faces into
shower
DCBA
78"
12" Min.
16" Recommended
20" Max.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
60"
54"
34"
eZ
Water inlets are opposite of how
typical plumbing is installed.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.
Porejemplo,silatina
esta conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
78"
48"
40"
12" Min.
16" Recommended
20" Max.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
54"
34"
8" 8"
One-Wall ExactTemp®3/4"
ExactTemp®3/4" de pulgada en una pared
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
9
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
e
Z
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Arrow on volume control
valve should always point in
direction of flow.
La flecha en la válvula de
control de volumen deberá
siempre apuntar en la
direccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera de
hidromasajevertical.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
10
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
One-Wall ioDIGITAL™3/4" with ceiling mount
ioDIGITAL™3/4" de pulgada para montaje
en el techo
GFCI
back of valve
faces into
shower
DCBA
78"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
60"
54"
42"
30"
eZ
Water inlets are opposite of how
typical plumbing is installed.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.
Porejemplo,silatina
esta conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
78"
48"
40"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
8" 8"
Arrow on volume control
valve should always point
in direction of flow.
La flecha en la válvula
de control de volumen
deberá siempre apuntar
enladireccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera
dehidromasajevertical.
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
One-Wall ExactTemp®3/4" with ceiling mount
ExactTemp®3/4" de pulgada para montaje
en el techo
11
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
e
Z
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
12
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
GFCI
back of valve
faces into
shower
DCBA
78"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
30"
42"
54"
60"
Two-Wall ioDIGITAL™3/4"
ioDIGITAL™3/4" de pulgada en dos paredes
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
eZ
Water inlets are opposite of how
typical plumbing is installed.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.
Porejemplo,silatina
esta conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
78"
48"
40"
12" Min.
16" Recommended
20" Max.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
54"
34"
8" 8"
Two-Wall ExactTemp®3/4"
ExactTemp®3/4" de pulgada en dos paredes
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
13
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
e
Z
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Arrow on volume control
valve should always point
in direction of flow.
La flecha en la válvula de
control de volumen deberá
siempre apuntar en la
direccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera
dehidromasajevertical.
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
14
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
GFCI
back of valve
faces into
shower
DCBA
78"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
60"
42"
54"
30"
Three-Wall ioDIGITAL™3/4"
ioDIGITAL™3/4" de pulgada en tres paredes
eZ
Water inlets are opposite of how
typical plumbing is installed.
4" Min.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.
Porejemplo,silatina
esta conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
78"
48"
40"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
8" 8"
Three-Wall ExactTemp®3/4"
ExactTemp®3/4" de pulgada en tres paredes
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor
equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Arrow on volume control
valve should always point in
direction of flow.
La flecha en la válvula de
control de volumen deberá
siempre apuntar en la
direccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando
utilice la válvula ExactTemp
de 3/4 de pulgada en una
configuración de bañera de
hidromasajevertical.
15
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
e
Z
4" Min.
42"
54"
34"
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
16
GFCI
back of valve
faces into
shower
DCBA
78"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
60"
This configuration
applies to Moen®
ioDIGITAL vertical
spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
Three-Wall ioDIGITAL™3/4"
ioDIGITAL™3/4" de pulgada en tres paredes
eZ
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
Water inlets are opposite of how
typical plumbing is installed.
42"
54"
30"
4" Min.
Optional remote
with holder bracket.
Control remoto opcional
conmontaje.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Note: Outlets A and B
constitute one valve body.
Outlets C and D constitute
another valve body.
High-flow devices (e.g., tub
spouts, multiple body sprays)
should be split up between
the A/B and C/D outlet pairs.
For example, if a tub spout is
connected to outlet B, 3 body
sprays should connect to C
or D, not A.
Nota: Las entradas A y B
constituyen una sola
válvula. Las entradas C y D
constituyen otra válvula.
Para dispositivos de alto
flujo(tinasyspasverticales)
divida la conexión entre los
pares de entradas A/B y
C/D.
Porejemplo,silatina
esta conectada a la entrada
B, conecte el spa vertical
a la entrada C o D, no a la
entrada A.
78"
54"
34"
48"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
8"8"
40"
Three-Wall ExactTemp®3/4"
ExactTemp®3/4" de pulgada en tres paredes
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
Arrow on volume control
valve should always point
in direction of flow.
La flecha en la válvula de
control de volumen deberá
siempre apuntar en la
direccióndelflujo.
Always cap the tub port
when using the ExactTemp
3/4" valve in a vertical spa
configuration.
Siempre tape el terminal
de la bañera cuando utilice
la válvula ExactTemp de
3/4 de pulgada en una
configuración de bañera
dehidromasajevertical.
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
17
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
e
Z
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
18
One-Wall Moentrol®with built-in
3-function transfer valve
Moentrol®para una pared con válvula de
transferencia integrada de 3 funciones
NOTE:
Moentrol with built-in
3-function transfer valve
not intended for use
with tub spout.
NOTA:
Moentrol con válvula de
transferencia integrada
de 3 funciones no está
diseñado para el uso con
pico de bañera.
BODY SPRAYS:
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
ROCÍOS PARA EL CUERPO:
Siempre se deberá utilizar
un distribuidor equilibrado
con los rocíos para el cuerpo
quepermitaelflujoigualde
agua para cada rocío.
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
78"
44"
12" Min.
16" Recommended
20" Max.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
54"
34"
e
Z
Transfer Valve Trim: Function Breakdown
Placas para válvulas de transferencia: Desglose de funciones
Function 1 Función 1
Función 2
(compartida)
Distribución
variable entre
componentes
Función 3
Control
de temperatura
y volumen
Function 2
(shared) Variable
sharing between
components
Function 3
Temperature
and Volume
Control
Shared
Function
Función
compartida
78"
44"
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fria
One-Wall Moentrol®with built-in
3-function transfer valve
Moentrol para una pared con válvula de
transferencia integrada de 3 funciones
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®
.
NOTE:
Moentrol with built-in
3-function transfer valve
not intended for use
with tub spout.
NOTA:
Moentrol con válvula de
transferencia integrada
de 3 funciones no está
diseñado para el uso con
pico de bañera.
19
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
e
Z
12" Min.
16" Recommended
20" Max.
Transfer Valve Trim: Function Breakdown
Placas para válvulas de transferencia: Desglose de funciones
Function 1 Función 1
Función 2
(compartida)
Distribución
variable entre
componentes
Función 3
Control
de temperatura
y volumen
Function 2
(shared) Variable
sharing between
components
Function 3
Temperature
and Volume
Control
Shared
Function
Función
compartida
All vertical dimensions (italicized) measured from floor. Dimensions listed are suggested.
Todas las dimensiones verticales (en cursivas) están medidas desde el suelo. Las dimensiones mencionadas son sugeridas.
*Minimum of 40 psi recommended for this configuration.
*Se recomienda un mínimo de 40 psi para esta configuración.
Vertical spa trim is compatible
withtheM•PACT®Common
Valve System.
Todos los componentes de la
bañeradehidromasajevertical
están basados en el sistema
comúndeválvulasM•PACT®.
One-Wall Moentrol®used with
3-function diverter valve
Dispositivo Moentrol®para una pared
con válvula de desvío de 3 funciones
This configuration
applies to Moen®
vertical spas.
Esta configuración de
bañera de hidromasaje
aplica a Moen®.
78"
44"
12" Min.
16" Recommended
20" Max.
HOT WATER INLET
Entrada de agua caliente
COLD WATER INLET
Entrada de agua fría
Shared
Function
Función
compartida
54"
34"
e
Z
To be installed
upside down, and also
flip the retaining clip.
3 Functions
2 discrete
1 shared
3 Funciones
2 separadas
1 compartida
Note: This configuration
is not intended for using
a tub spout.
20
BODY SPRAYS:
Thread the body sprays
onto a 1/2" NPT supply
pipe. Pipe should protrude
1/2"– 5/8" from the wall.
ROCÍOS PARA EL CUERPO:
Enrosque los dispositivos
para rocío del cuerpo a un
tubo de suministro de 1/2
pulgada NPT.
A pressure-balancing loop
must always be used with
body sprays to allow for
equal supply of water to
each spray.
Siempre se deberá utilizar
un distribuidor equilibrado
con los rocíos para el
cuerpoquepermitaelflujo
igual de agua para cada
rocío.
Always cap the shower
port when using the
Moentrol®valve in a
vertical spa configuration.
Siempre tape el terminal
de la regadera cuando use
la válvula Moentrol®en la
configuracióndehidromasaje
vertical.

This manual suits for next models

1

Popular Hot Tub manuals by other brands

Jacuzzi Select Series owner's manual

Jacuzzi

Jacuzzi Select Series owner's manual

MAAX Spas California Cooperage 2006 owner's manual

MAAX Spas

MAAX Spas California Cooperage 2006 owner's manual

Aquatic iNfiNity serIes Owner's manual & installation guide

Aquatic

Aquatic iNfiNity serIes Owner's manual & installation guide

Aquatic Century 30 AI6042RC30 Specification sheet

Aquatic

Aquatic Century 30 AI6042RC30 Specification sheet

Hot Tub Barn Hot Spot SX installation instructions

Hot Tub Barn

Hot Tub Barn Hot Spot SX installation instructions

Gecko Aeware Advanced in.k600 Quick reference card

Gecko

Gecko Aeware Advanced in.k600 Quick reference card

Aleko HTIO2BLD Assembly guide

Aleko

Aleko HTIO2BLD Assembly guide

American Standard Renaissance 2771VA installation guide

American Standard

American Standard Renaissance 2771VA installation guide

Conair BTS4C Series Instruction booklet

Conair

Conair BTS4C Series Instruction booklet

Jacuzzi NOVA 536 Specification sheet

Jacuzzi

Jacuzzi NOVA 536 Specification sheet

Bossini Soffione Yoko I00522 INSTALLATION AND CARE INSTRUCTIONS

Bossini

Bossini Soffione Yoko I00522 INSTALLATION AND CARE INSTRUCTIONS

Jacuzzi U961000G Installation and operating instructions

Jacuzzi

Jacuzzi U961000G Installation and operating instructions

Intex PureSpa 128462 quick start guide

Intex

Intex PureSpa 128462 quick start guide

Aqua Pulse Spas Lorne Luxury user manual

Aqua Pulse Spas

Aqua Pulse Spas Lorne Luxury user manual

Jacuzzi 2003+ owner's manual

Jacuzzi

Jacuzzi 2003+ owner's manual

Jacuzzi Premium J-315 owner's manual

Jacuzzi

Jacuzzi Premium J-315 owner's manual

Image 831.10815 user manual

Image

Image 831.10815 user manual

NETSPA NOVARDEN SP-SLV155 Installation and user manual

NETSPA

NETSPA NOVARDEN SP-SLV155 Installation and user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.