InstallationInstallation
Page 3
XT0015 - 150324
6. Using the supplied cable ties and self-adhesive cable tie mounts,
secure the fan harness to the bottom of the rebox. Make sure to
keep the wires away from fan blades and door buckles.
7. Reinstall the burner tray (if removed). See Figure 2 or Figure 3 for
examples
8. Complete the installation as per the replace installation manual.
Program the remote transmitter to the control box as per the
supplied "Proame2 Operation and Maintenance Manual-
XG0677" and start-up your replace. Turn the fans on using the
remote control.
9. Use the remote control to adjust the fan speed to the desired set-
ting.
The fans only operate when the unit is running. You may
turn the fans o completely using the remote control.
Figure 7
Wiring for the optional Fan Kit
Thefollowingreplacesmaybeequippedwithoptionalfankits:H*42DF*,
H*34DF*, H*38DF*, L*42DF*, L*38DF*, L*52DF*.
InstallationsinCanadawhichemploythefansmustbeelectrically
groundedinaccordancewithCSAC22.1CanadianElectricalCode
Part 1 and/or Local Codes.
InstallationsintheUSAwhichemploythefansmustbegrounded
inaccordancewithlocalcodesor,intheabsenceoflocalcodes,with
the National Electrical Code, ANSI/NFPA 70.
NOTE: If any of the original wire supplied with the appliance
is replaced, it must be replaced with the same type,
or its equivalent.
Figure 8. Wiring diagram for optional fans.
G
L2-WH
L1-BLK
pg
QuickConnect
lu to motor
5/1/60 Supply
G L1 L2