Driver Installation Guide
For MCS98XX on DOS
1 May, 2007
Normally any serial and parallel I/O ports can be supported by BIOS call services in DOS
environment. However DOS supports only 4 serial ports (3F8h, 2F8h, 3E8h, 2E8h) and
3 parallel ports (3BCh/378h/278h).
I. Contents available in Moschip DOS Driver:
1. NMDOSIN.EXE --- DOS Utility to install ports.
2. NMCONFIG.CFG --- Configuration file to Remap to customize
I/O Addresses.
3. DOS Driver Installation Guide.doc --- PDF Document of Installation Guide.
II. Options:
-a[dd] = Add Moschip Ports
-c[onfig]:<parameters> = Configure Moschip Ports
-d[elete] = Delete Moschip Ports
-r[emap] = Remap Moschip ports to legacy ports
-s[ilent] = Silent mode
-t[est] = Test ports (requires external Loop-Back plugs)
-u[nused] = remap to all Unused legacy port i/o base,
without consideration of COM/LPT number
-f = remapping to customize I/O addresses.
III. Installation Procedure:
The following procedure explains how to install Moschip serial and parallel port
device driver on DOS.
Step 1: Copy "NmDosIn.exe" to 'C' Drive from Floppy. The command is "copy a:\ NmDosIn.exe c:\"
Step 2: Type "nmdosin" to confirm Device detection. (eg. MCS9835)
Found Moschip Technology pci device 9835 (00121000) Rev01 on Bus00 Slot 0A
Serial Port1 at A000
Serial Port2 at A400
PrinterPort1 at A800
Detected 1 pci device(s).