Moxa Technologies VPORT P06-1MP-M12 User manual

P/N: 1802000060015
*1802000060015*
VPort P06-1MP-M12 Series
Quick Installation Guide
Moxa IP Camera
Version 6.0, August 2022
Technical Support Contact Information
www.moxa.com/support
2022 Moxa Inc. All rights reserved.

- 2 -
Overview
The compact VPort P06-1MP-M12 cameras provide an HD (720P, 1280
x 720) video image, and feature an H.264/MJPEG IP dome, giving them
the versatility and ruggedness to excel in many different installations
and environments for mobile IP video surveillance applications. In
addition, the cameras are compliant with mandatory sections of EN
50155, covering operating temperature, power input voltage, surge,
ESD, and vibration, as well as conformal coating and power insulation,
making them suitable for a variety of industrial applications. The
cameras feature vandal-proofing (EN 62262 IK10), a -25 to 55°C or -40
to 70°C (T models) operating temperature range, a rugged M12
Ethernet port, 1 audio input, PoE power inputs, IP66 rain and dust
protection, a dehumidifying membrane, and a selectable lens.
Ordering Information
Moxa’s VPort P06-1MP-M12 is shipped with the following item:
•VPort P06-1MP-M12 (lens included)
If this item is missing or damaged, please contact your customer
service representative for assistance.
The following models are available:
EN 50155, T1
EN 50155, TX
Lens Focal
Length
Line-in/
Microphone
-25 to 55°C
-40 to 70°C
VPort P06-1MP
-M12-CAM28
VPort P06-1MP
-M12-CAM28-T
2.8 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM28
VPort P06-1MP
-M12-MIC-CAM28-T
2.8 mm
Microphone-
in
VPort P06-1MP
-M12-CAM36
VPort P06-1MP
-M12-CAM36-T
3.6 mm Line-in
VPort P06-1MP
-M12-MIC-CAM36
VPort P06-1MP
-M12-MIC-CAM36-T
3.6 mm
Microphone-
in
VPort P06-1MP
-M12-CAM42
VPort P06-1MP
-M12-CAM42-T
4.2 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM42
VPort P06-1MP
-M12-MIC-CAM42-T
4.2 mm Microphone-
in
VPort P06-1MP
-M12-CAM60
VPort P06-1MP
-M12-CAM60-T
6.0 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM60
VPort P06-1MP
-M12-MIC-CAM60-T
6.0 mm
Microphone-
in
VPort P06-1MP
-M12-CAM80
VPort P06-1MP
-M12-CAM80-T
8.0 mm Line-in
VPort P06-1MP
-M12-MIC-CAM80
VPort P06-1MP
-M12-MIC-CAM80-T
8.0 mm
Microphone-
in
VPort P06-1MP
-M12-CAM28-CT
VPort P06-1MP
-M12-CAM28-CT-T
2.8 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM28-
CT
VPort P06-1MP
-M12-MIC-CAM28-
CT-T
2.8 mm
Microphone-
in
VPort P06-1MP
-M12-CAM36-CT
VPort P06-1MP
-M12-CAM36-CT-T
3.6 mm
Line-in

- 3 -
EN 50155, T1
EN 50155, TX
Lens Focal
Length
Line-in/
Microphone
-25 to 55°C
-40 to 70°C
VPort P06-1MP
-M12-MIC-CAM36-
CT
VPort P06-1MP
-M12-MIC-CAM36-
CT-T
3.6 mm Microphone-
in
VPort P06-1MP
-M12-CAM42-CT
VPort P06-1MP
-M12-CAM42-CT-T
4.2 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM42-
CT
VPort P06-1MP
-M12-MIC-CAM42-
CT-T
4.2 mm Microphone-
in
VPort P06-1MP
-M12-CAM60-CT
VPort P06-1MP
-M12-CAM60-CT-T
6.0 mm
Line-in
VPort P06-1MP
-M12-MIC-CAM60-
CT
VPort P06-1MP
-M12-MIC-CAM60-
CT-T
6.0 mm Microphone-
in
VPort P06-1MP-
M12-CAM80-CT
VPort P06-1MP-
M12-CAM80-CT-T
8.0 mm
Line-in
VPort P06-1MP-
M12-MIC-CAM80-CT
VPort P06-1MP
-M12-MIC-CAM80-
CT-T
8.0 mm Microphone-
in
Screw handle accessory package
Torx screw driver for
attaching/detaching
the upper case.
4 sets of nuts, gaskets
,
and spring washers for
mounting the camera.
4 indented hexagonal
head tapping screws
for mounting the
camera on the ceiling.
Grounding screw for
connecting the device
to a grounding surface.

- 4 -
Sticker for camera mounting positions
•
Quick installation guide
•
Warranty card
NOTE
Check the model name on the VPort’s side label to determine if
the model name is correct for your order.
NOTE
This product must be installed in compliance with your local
laws and regulations.
Features
•1/2.7” HD progressive CMOS image sensor
•High image quality with WDR (wide dynamic range) and DNR
(Digital Noise Reduction) supported
•Minimum illumination up to 0.2 lux (color)
•Supports MJPEG and H.264 Dual Codecs
•Provides 3 video streams for H.264 and MJPEG simultaneously
•Video stream up to 30 frames/sec at WXGA (1280 x 800) resolution
•Supports video quality configuration with fixed bit rate (CBR) and
fixed quality (VBR)
•Video latency under 200 ms
•DynaStream™ for network efficiency with dynamic frame rates
•CBR Pro™ supported for high image quality with limited bandwidth
transmissions
•WXGA, 720P, SVGA, Full D1, 4CIF, VGA, CIF, QCIF resolution
•TCP, UDP, and HTTP network transmission modes
•Supports DHCP OPT66/67 for automatic configuration from TFTP
server, making it easy to batch-configure several units
•Supports RTSP streaming
•Supports multicast (IGMP) video streaming
•Supports SNMP (V1/V2C/V3) for network system integration and
management
•Supports QoS (ToS) for transmission priority
•Built-in web server for easy configuration
•Accessible IP filtering
•UPnP supported
•Complies with all EN 50155 mandatory test items*

- 5 -
*This product is suitable for rolling stock railway applications, as
defined by the EN 50155 standard. For a more detailed statement, click
here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
•1 10/100BaseT(X) port with M12 D-code connector
•1 audio input with water-proof RCA-type connector, or 1 built-in
microphone
•IP66 rain and dust protection, with dehumidifying membrane
•PoE (Power-over-Ethernet, IEEE 802.3af) supported
•EN 62262 IK10 level vandal resistance
•-25 to 55°C (EN 50155, OT1), or -40 to 70°C (EN 50155, OT4)
operating temperature for rolling stock environments
•CE, FCC, UL 62368-1
•Built-in tamper alarm and Video Motion Detection (VMD)
•Pre, trigger, and post snapshot images supported
•Supports sequential snapshot images
•Supports FTP for alarm message transmission
•Supports HTTP event server
•5-year warranty
Product Description
Appearance
•
4-pin D-coded M12 Ethernet
connector: Can be used for both
the
PoE power supply (Mode A) and
an Auto MDI/MDI-X Ethernet
connection.
Transparent
Dome cover
4-pin D-code M12
Ethernet connector
RCA female
Connector
(only available in
models with line-
in audio)
Solid plastic
top cover
Aluminum
bottom plate
Torx screw
for top cover
Built-in Microphone (-MIC model)

- 6 -
NOTE
To connect the VPort P06-1MP-M12 to a network, use an
Ethernet cable with
a D-coded M12 connector and an M12 PoE
switch or RJ45 PoE switch
M12 D-code to M12 D-code
cable
M12 PoE switch (e.g., TN-
5508-4PoE)
M12 D-code and RJ45 cable
RJ45 PoE switch
(e.g., EDS-P510)
NOTE
The power input rating of the VPort P06-1MP-M12 is 48 VDC,
0.12 A, with maximum power consumption
of approximately 6
W.
NOTE
The equipment is designed for in-building installation only and
is not intended to be connected to exposed (outside the plant)
networks.
•RCA female connector: The VPort P06-1MP-M12 supports one
audio input with RCA female connector. The audio will be digitized
and compressed as an audio stream for network transmission with
the video stream.
NOTE
RCA audio connectors are popular and easily found in the
market. If you require any other kind of audio connector,
please contact your Moxa sales representative for customization
service.
•Solid plastic top cover: This top cover can be removed for tuning
the camera lens position.
•Transparent dome cover: The VPort P06-1MP-M12 is designed
with a transparent PC dome cover, which is vandal-proof and
satisfies EN 62262 (IEC 62262) Class IK10 requirements.
•2 Torx screws for top cover: These 2 torx screws are designed
with anti-shedding to make installation more convenient. Use the L-
type torx screwdriver to remove or attach the top cover.
•Built-in microphone: The VPort P06-1MP-M12-MIC Series
products have a built-in microphone, and can simultaneously
display or record live video and audio.

- 7 -
NOTE
The color of the form factor can be customized based on your
installation environment. Please contact your Moxa sales
representative for customization service.
Inside the Camera
•Mounting screw holes: There are 4 mounting screw holes for
mounting the VPort P06-1MP-M12 on the ceiling or the accessory.
•Thumb screw for fixing the lens position: To tune the lens
position, loosen the thumb screw, tune the lens, and tighten the
thumb screw again.
•Lens with fixed focal length: The VPort P06-1MP-M12 Series
includes models with 3 different focal lengths. Choose the
appropriate focal-length lens based on the viewing angle and object
distance.
•Hardware reset button: Use a pointed object to depress the reset
button to reboot or restore factory defaults.
Reboot: Press the button one time.
Factory default: Press and hold the button for at least 90
seconds.
Microphone line (-MIC model)

- 8 -
•Calibration for rotating the lens (0 to 360°): Rotate the lens to
get the optimal image. When done, mark the position of this
calibration for future placement or mass installation.
•Calibration for tuning the vertical position of the lens (0 to
90°): After tuning the vertical position of the lens, mark the
position of this calibration for future placement or mass installation.
•Calibration for tuning the horizontal position of the lens (±
30°): After tuning the horizontal position of the lens, mark the
position of this calibration for future placement or mass installation.
Hardware Installation
Step 1: Open and remove the top cover.
Use the torx screwdriver to loosen the top cover screws.
Step 2: Use the installation sticker for drilling the holes. There
are 3 types of installation.
a.
Mounting with 4 mounting screws
To mount the camera on the ceiling, drill a hole through the gray
portion of the sticker and then mount the camera with the 4
nut/gasket/spring
-washer sets and 4 indented hexagonal head
tapping screws.

- 9 -
NOTE
The 4 screws for mounting the VPort P06-1MP-M12 are M4 type
with a 30
mm length thread.
b.
Mounting with the side-cable-out adapter
Use the side-cable-out adapter
(VP
-SCO1) if your installation
requires the cable
–out on the
side. Drill a hole through the
blue portion of the sticker for
mounting the adaptor on the
surface with 3 nut/gasket/
spring
-washer sets and
indented hexagonal head
tapping screws
(include
d in the
VPort
P06-1MP-M12 package).
N
ext, mount the VPort P06-
1MP
-
M12 on the adapter with 4
M4 screws, which are provided
in the VP-SCO1’s package.
VP-SCO1

- 10 -
NOTE
The 4 screws for mounting the VPort P06-1MP-M12 onto the
VP
-SCO1 are M4 type with a 12 mm length thread.
c.
Mounting with the fixed plate
If you cannot use the
nut/gasket/spring
-washer set
to mount the camera on your
ceiling, use the VP
-FP1 fixed
plate. Drill holes through the
green dotted
-line holes and 4
camera mounting screw holes
on the sticker, and
then put
the VP
-
FP1 inside the hole. Use
the 2 countersink screws to
mount the VP
-FP1. Finally,
mount the VPort P06
-1MP-
M12
on the fixed plate with the 4
indented hexagonal head
tapping screws.
VP
-FP1

- 11 -
NOTE
The screw hole for mounting the VP-FP1 fixed plate is a
countersunk hole with 5 mm diameter, and 90° 2 x 2 mm
chamfer. Take this into consideration when drilling these 2
screw holes.
NOTE
The 2 screws for mounting the VP-FP1 onto the ceiling are M4
type with
a 16 mm length thread.
Step 3: Connect the camera with
the 4
-pin M12 D-code Ethernet
connector and RCA male
connector.
Step 4: Loosen the thumb screw
to
rotate and tune the horizontal
and vertical position of the lens
.
Once the lens position is correct,
fix the thumb screw.
Step 5: Fix the top cover. The installation is now complete.
Software Installation
Step 1: Configure the VPort P06-1MP-M12’s IP address
When the VPort P06-1MP-M12 is first powered on, the POST (Power On
Self Test) will run for a few moments (about 30 seconds). The network
environment determines how the IP address is assigned.
Network Environment With DHCP Server
For this network environment, the unit’s IP address will be assigned by
the network’s DHCP server. Refer to the DHCP server’s IP address table
to determine the unit’s assigned IP address. You may also use the
MXconfig network configuration tool as described below:
Using the MXconfig Network Configuration Tool
1. Download the MXconfig software from
https://www.moxa.com/en/products/industrial-network-

- 12 -
infrastructure/network-management-software/mxconfig-series.
2. Run the MXconfig software utility. After the utility’s window opens,
click the Search button to initiate a search.
3. When the search has concluded, the model name, IP and MAC
address, and firmware version of the VPort will be listed in the
utility’s window.
You can double-click the selected VPort, or use the IE web browser to
access the VPort’s web-based manager (web server).
Non-DHCP Server Network Environment
If your VPort is connected to a network that does not have a DHCP
server, then you will need to configure the IP address manually. The
default IP address of the VPort is 192.168.127.100 and the default
subnet mask is 255.255.255.0. Note that you may need to change your
computer’s IP address and subnet mask so that the computer is on the
same subnet as the VPort.
To change the IP address of the VPort manually, access the VPort’s web
server, then navigate to the System Configuration Network
General page to configure the IP address and other network settings.
Check Use fixed IP address to ensure that the IP address you assign
is not deleted each time the VPort is restarted.
Step 2: Access the VPort P06-1MP-M12’s web-based manager.
Type the IP address in the web browser’s address bar and then press
enter.
Step 3: Install the ActiveX Control Plugin.
A security warning message will appear the first time you access the
VPort’s web-based manager. The message is related to installing the
VPort AcitveX Control component on your PC or notebook. Click Yes to
install this plugin to enable the IE web browser for viewing video
images.

- 13 -
NOTE
For Windows XP SP2 or above operating systems, the ActiveX
Control component will be blocked for system security reasons.
In this case, the VPort’s security warning message window may
not appear.
You should unblock ActiveX or temporarily disable
browser security
to enable the installation of the VPort’s ActiveX
Control component.
Step 4: Configure authentication for accessing the VPort’s web-based
management interface.
You will need to log in to access the VPort's web-based interface. The
default administrator account name is “admin” and the default
password is “moxamoxa”. After accessing the camera using the default
admin password, you will need to change the password for security
reasons.
When accessing the web UI for the first time, use the default login:
Account name: admin
Password: moxamoxa.
If you log out and log back in without changing the password, the
Change Password dialog will appear. You will need to change the
password to proceed.
Step 5: Access the homepage of the VPort P06-1MP-M12's web-based
manager.
After installing the ActiveX Control component, the homepage of the
VPort P06-1MP-M12’s web-based manager will appear. Check the
following items to make sure the system was installed properly:
1. Video Images
2. Video Information

- 14 -
Step 6: Access the VPort’s system configuration.
Click on System Configuration to access the overview of the system
configuration to change the configuration. Model Name, Server
Name, IP Address, MAC Address, and Firmware Version appear on
the green bar near the top of the page. Use this information to check
the system information and installation.
For details of each configuration, check the user’s manual which can be
downloaded from www.moxa.com.
Wiring Requirements
ATTENTION
Safety First!
Be sure to disconnect the power cord before
installing and/or
wiring your Moxa VPort P06
-1MP-M12. Calculate the maximum
possible current in each power wire and common wire. Observe
all electrical codes dictating the maximum current allowable for
each wire size. If the current goes above the maximum ratings,
the wiring could overheat, causing serious damage to your
equipment.
You should also pay attention to the following:
•Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.

- 15 -
•You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb
is that wiring that shares similar electrical characteristics can be
bundled together.
•Keep input wiring and output wiring separate.
•We strongly advise labeling wiring to all devices in the system.
Grounding the VPort-P06-1MP-M12
The grounding screw accessory can be used to connect the VPort
camera to ground. If required, the grounding screw can be inserted in
the grounding hole located on the VPort P06-1MP-M12’s aluminum
bottom plate. Grounding and wire routing help limit the effects of noise
due to electromagnetic interference (EMI). Run the ground connection
from the grounding screw to the grounding surface prior to connecting
devices.
NOTE
The grounding screw is exclusively used to ground the VPort
camera. Do not use it to ground other devices and equipment.
Dimensions (mm)
Front View
Bottom View
Top View
Camera with SCO1 adaptor
Specifications
Input Current
0.12 A @ 48 VDC
Operating Temperature
Standard Models: -25 to 55°C (-13 to
131°F)
Wide Temp. Models: -40 to 70°C (-40 to
158°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)

- 16 -
NOTE
The equipment is intended to be supplied by an external power
source (UL listed/IEC 60950
-1/IEC 62368-1), of which the
output complies with ES1/SELV/PS2/LPS, and the output rating
is 48 VDC, 0.12 A minimum in ambient temperatures of at least
70°C.
If you
are using a Class I adapter, the power cord should be
connected to an outlet with an earthing connection.
Other manuals for VPORT P06-1MP-M12
2
This manual suits for next models
40
Table of contents
Other Moxa Technologies Security Camera manuals