TERMINAL CONNECTION
Front view (mm)
MECHANICAL INSTALLATION
CTR-632
CURRENT TRANSDUCER
Linearized O/P
1.5KV isolation between supply, input &
output
FEATURES
TECHNICAL SPECIFICATION
Zero & span correction facility through
trim port
Fast Response time <150ms
Din Rail Mounting
Input
INPUT SPECIFICATION:
0 to 5Amp AC (True RMS)
CMRR >120dp (Typical)
Temperature
Co-efficient <100 PPM
Output 1 & 2
OUTPUT SPECIFICATION:
Output Inpedance <500Ω
4 to 20mA DC
Response Type <150ms
Isolation between
supply, input & Output At least 1.5KV AC for 1 min
Auxiliary Voltage
POWER SUPPLY:
100 to 270V AC,50/60Hz
Isolation Type Optical - 3 way
ISOLATION:
DIMENSION:
Size (HxWxD) mm 76 X 27 X 85
76 76
27
85
Side view (mm)
Power Consumption
( VA Rating ) 4VA @230V AC
Input
0 To 5Amp AC
Supply
100 To 270V AC
50/60Hz, 4VA
Output 2
4 To 20mA DC
Output 1
4 To 20mA DC
O/P-2 O/P-1
S1
S2
Z1
Z2
CTR 632
SUPPLY
A1 A2
www.multispanindia.com Made in India
!
CTR 632
Z1Z2
S1
S2
O/P-2 O/P-1
I/P
A1 A2
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
tha appear in this operating manual or on the equipment must
be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified by
the manufacturer, it might impair the protection provided by
the equipment.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
INSTALLATION GUIDELINES
MECHANICAL INSTALLATION GUIDELINES
MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
1) To install the instrument on a DIN rail, raise the clamp at
the back of the instrument and place it on the rail. Now
release the clamp, so the instrument fits on the DIN rail.
2) Ensure proper fitting of the instrument by pulling it
outwards.
3) To remove the instrument raise the clamp to release it
from the DIN rail.
4) The equipment in its installed state must not come in
close proximity to any heating source, caustic vapors, oil
steam, or other unwanted process byproducts.
5) Do not connect anything to unused terminals.
1) Do not allow pieces of metal, wire clippings, or fine
metallic fillings from installation to enter the product or
else it may lead to a safety hazard that may in turn
endanger life or cause electrical shock to the operator.
2) Circuit breaker or mains switch must be installed
between power source and supply terminal to facilitate
power ‘ON’ or ‘OFF’ function. However this mains switch
or circuit breaker must be installed at convenient place
normally accessible to the operator.
3) Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.

Popular Transducer manuals by other brands

Maretron DST110 user manual

Maretron

Maretron DST110 user manual

AERMEC NRA manual

AERMEC

AERMEC NRA manual

HESCH HE 5409 operating instructions

HESCH

HESCH HE 5409 operating instructions

Simex TRS-02a user manual

Simex

Simex TRS-02a user manual

Raymarine RVM-100 installation instructions

Raymarine

Raymarine RVM-100 installation instructions

ECHOMAX XRS-5 Operation manual

ECHOMAX

ECHOMAX XRS-5 Operation manual

GE CF-LP manual

GE

GE CF-LP manual

Terwin 2000 Series quick start guide

Terwin

Terwin 2000 Series quick start guide

CARLO GAVAZZI SPT-90 operating instructions

CARLO GAVAZZI

CARLO GAVAZZI SPT-90 operating instructions

MG 18RP instruction manual

MG

MG 18RP instruction manual

Aerospace Logic FF200X Series Operation guide

Aerospace Logic

Aerospace Logic FF200X Series Operation guide

Veris Industries PW Series installation guide

Veris Industries

Veris Industries PW Series installation guide

Raymarine RV-300 Series installation instructions

Raymarine

Raymarine RV-300 Series installation instructions

FujiFilm SonoSite TEExp user guide

FujiFilm

FujiFilm SonoSite TEExp user guide

M-system LT-UNIT Series quick start guide

M-system

M-system LT-UNIT Series quick start guide

MAMAC SYSTEMS PR-264 technical information

MAMAC SYSTEMS

MAMAC SYSTEMS PR-264 technical information

Balluff BTL6-V5 V-M PF-S115 Series user guide

Balluff

Balluff BTL6-V5 V-M PF-S115 Series user guide

Siedle Novotechnik TLM Series manual

Siedle

Siedle Novotechnik TLM Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.