14.10Adjustthelength
ofthe
flue/terminal
assembly
-see
Fig.11
(side
flue).
l. Usingthem@surementsnotedin section
14.8,
adjustthe
lengthof the
flue/terminalassemblyso
that
it is:
127mm
(5in)+A + B,fromtheback
of theterminalflange
totheend
of the
OUTER
airtubeasshown
in Fig. Il.
WhereA isthe
finishedwallthicknessand
B isthedistance
between
thesidewall andthesideof the
white
case.
Note:
Ensurethattheseams
inthe
outerairtubesare
inline.
2. Drill throughthethree
pilotholes,
shown
inFig. I l, witha
2.8
mm
drilland
securethe
two
tubes
togetherusingthethree
No.8x l0lg. screwssup'plied
with
the
fluelterminal
assernbly.
Note:
Whendrillingthroughtheouterairtubetakecarenot
todamageiheinner
fluetube
with thedrill.
3. Sealthecenre
jointwiththetape
supplied
with
theflue/terminal
assembly.
l4.ll Flue
extension
-see
Fig.12
(side
flue).
Theflue
extension
kitallowsthestandard
flue/terminal
assembly
tobe
extendedby965
mm(38in).
A maximum
of twoflueextension
maybeused,
if required.
l. If theflueextensionkit isused,connectthe
plain
endofthe
extensionto theswagedend
of thesondard
flue/terminal
assembly.Ensure
thatthe
innerflue
tubeof
thestandafiflue/
terminal
fis INSIDEthe
innerfluetubeoftheextensionand
theouteraL tubefits OVERtheair tubeof theextension.
Pushfullyhome.
Note:
Ensurethattheseams
intheouter
airtubes
are
inline.
Seal
this
loint
with tapesupplied..
Extension Keeps
seamsin line Standard
flueltermrnal
assemblv
Fig. 12
2. Drill threeequally
spaced
holes
usinga2.8
mmdrill inthe
position
shown
inFig. 12,
through
boththestandard
fluelterminal
andtheextensiontubesleeve.Serurethetwo
&bes
togetherusing
thethree
No.8x l0lg. screws
suppliedwiththeflueextension.
Note:
Whendrillingthroughtheouterairtubetakecare
not
to
damage
the
inner
flue
tube
withtlredrill.
3. Sealthe
lrints withthetape
supplied
withthe
flueextension.
4. AdjusttheOVERALL
length
asdescribed
insection
14.10.
Secureand
seal
the
joins.
14.12
Fittheflue/terminal
pssembly-s€€
Fig.13
(side
flue).
Note:
If the
wall istobemade
good
upto the
terminal,tlreouter
wall
plate
neednotbeus€d.
l. Fit theouter
wallplate
overthe
flue/terminal
assembly.
2. Fitthe
'O' ringinposition
over
theouterairtube
against
theflared
section.
3. From
outsidethebuilding
insert
the
flue/terminal
assembly
into
the
wall.Ensure
that
theslos in theendof theterminal
are
vertical.
4. Pushtheflue/terminalassemblytowardsthe
boilerandengagethe
tube
into
theflue
diverter
ontopofthe
boiler,
ensuring
thatthe
inner
fluetube
slidesINTOthe
inner
tube
ofthe
diverter
andtheouter
air
tubeslides
intothe
diverter.
Checkthatthe
'O' ringisonthe
boilersideof theflaredsection.
Push
fully home
untilthe
flared
endof the
outertube
isincontact
with thefluediverter.
14.13
Connect
the
fluetotheboiler
- see
Fig.14
(side
flue).
l. FitthetwohalvesoftheclampingringovertheairtubeasshowninFig.14.Ensure
thatthe
flatside
isfacing
away
fromthe
boiler,andthe
recessed
side
isagainstthe
flared
part
of theairtube.
2. Securetheclamping
ring
to
theflue
diverterusingthe
fourM4screwssupplied
(use
thethreaded
holes
in theclampingring).
3. Tighten
thescrews
toseal
theflueassembly.
4. Make
good
the
gap
onthe
inside
wallaroundthe
fluetube.
Fig.14
Sealthrs;oint
wrlh tape
supplied , Pilor holes (3 off)
Keep seams rn lrne
+--
Finished wall thickness +8+ 127mm (5 tn)
Fig.11
Page
I0