National Security Systems All-Safe 4 Zone P.A. SYSTEM User manual

MODEL : 4/8 ZONE P.A. SYSTEM
ERTL TESTED AS PER IS:2189
S
e
c
u
rit
y
D
e
v
i
c
e
s
OFFICE : 485/14, SARPANCH KA BARA, MANDAWALI
FAZALPUR, DELHI-110092
WORKS : 2-A, Patparganj, Mayur Vihar,
Phase - 1, Delhi - 110091
PHONE : 011 - 22751020, 64603599, Fax: 011 - 22751020
MOBIL : 9891222660, E-mail : [email protected]
NATIONAL SECURITY DEVICES

INDEX
[1] Introduction..................
General
[2] General Features..................
Mechanical Construction
[3] Installation & Commissioning..
Installation
Commissioning
[4] Indicator and controls..
Indicator
Controls
[5] Input and Output.........
Zone Monitor
Power Monitor
Output
Controls
[6] Technical Data...........
[7]
[8] Warranty
[9] Test Report
About The product

1
We heartily welcome you in the family of NATIONAL SECURITY DEVICES , is well
known name in the field of mfg fire alarm systems . We came in to the field of manufacturing and
with in a short span of a decades time, We succeed to achieve upper layer of the industry, got good
response & respect from the customer for quality product & timebond services . Still aiming to
keep the high standard with our professionals , advanced technology, computerized R& D , in -house
tool room/assambly plant and of course our skilled workmanship with the strict quality control.
This manual intended as a complete guide to the model manual control panel.
This microprocessor based fire alarm control Panel is implemented with wide range of application
required in basic alarm Automation .
This panel is designed to meet the general requirement of IS 2189:1999.Basically
these system used in residential society sensitive area where fire can prevented auto/manua
prevention by fire fighting depart/duty persons.
About The Company
About The Product
System Design and Plan

2
GENERAL DESCRIPTION
The microprocessor based automatic alarm and Control indication panel is designed to individual
zoning the fire input and evacuated /alert fire in earliest practicable moment with the help announcement
type hooter output .The panel operates on 220 V AC Mains with 24 V DC Battery as a stand by power ,
The built in circuit provide constant voltage charging to maintain the battery capacity.
Fire alarm status 16 x2 line characters LCD Display
High quality unidirectional mike for announcement.
Dual function audio system for hooter cum announcement.
Low battery visual warning with Audio able tone.
Zone wise fire fault Operating indication Facility.
Zone ON indication Facility.
P.A Announcement Hooter Output with silence facility.
Manual test/Evacute facility/Selector with All-Call facility.
Rugged CRCA sheet with powder coated finish.
Modular Construction.
Relay Output for associate gadgets.
Stand by battery backup with Built in charging.
MECHANICAL CONSTRUCTION
The enclosure of the panel is constructed by CRCA Sheet with powder-coated finish and its designed
to afford the degree of protection as per IP54 , The 20 mm Knock outs are given for cable entry at the
top of the cabinet.The Panel has a built in battery space for 2Nos of 12 V , 7 AH Batteries.
The front side of the panel consist of the following
1) Control Switches
2) LED Indication

3
INSTALLATION AND COMMISSIONING
Installation
The installation of the Fire detection and alarm should comply with
a)The installation of the Electrical engineers (IEE) wiring regulation and standards.
b)The Indian Standard of fire Detection and alarm for building.
c)The installation cable should not be in the area of proximity of high voltage cable or
induce electrical interference.
Place the panel in its outing Position and fix the panel to the wall using the slot of the screw , Ensure the
enclosure and the inner parts of the panel are given sufficient protection during installation period . All
external cables are to be entered via the 20 mm performed knockout located at the top of the panel .
After the installation of all cables has been completed , clean the interior of the enclosure ensuring all
masonry debris and drilling swords are removed.
COMMISSIONING
Check all entered wiring is correctly identified and also check all free from fault condition
by a multi meter . Connect the external wiring into their respective terminal and ensure the end of
line (EOL ) resistor is placed at the last device of circuit.
Prior to the power up of the panel conduct the following preliminary checks
a)check for any external signs of damage caused during installation
b)Checks all PCBs are screw in its mounting position.
c)Check all cable are secure and correctly connected.
d)Check all the cable termination is tight & Secure.
e)Connect the batteries ensuring the correct polarity.
All damages / Fault must be rectified before proceeding
All hooter should be LMT(Line matching type) .otherwise your product will damage immediately
Never make common -Ve for hooter &detection line it will create malfunction /false alarm.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MAINS ON
SYSTEM ON
CHARGER ON
FUSE BLOWN
LOW BATTERY
FIRE LED
FAULT LED
ZONE TEST
WALK TEST
LAMP TEST
EVACUTE
SILANCE
RESET
LOCK & KEY
ALL CALL SWITCH
SELECTOR SWITCH
17
19
20
SELECTOR LED
MIKE SWITCH
MICROPHONE
CONTROL & FEATURES
NATIONAL SECURITY DEVICES
OFFICE : 485/14, SARPANCH KA BARA, MANDAWALI
FAZALPUR, DELHI-11092
PHONE : 011-22751020, 64603599 FAX : 01122751020
MOBILE : 9891222660, E-MAIL- MAILANILRAWA[email protected]
TITLE Fire Alarm With PA System Panel
Controls & Features

4
INDICATOR AND CONTROLS
ZONE MONITOR
INDICATIONS
NORMAL: SYSTEM NORMAL information display on 16 X2 characters LCD .This time system
ON power ON & Charger ON LED green glowing .
FIRE : In case of fire LCD Display the information of respective zone with single RED LED glow.
Normally these LED are OFF state. In case multiple zone indicates fire LCD alternately
display the massage with zone no.
OPEN : In case of zone line/detector open LCD Display the information of respective zone with single
YELLOW LED glow. Normally these LED are OFF state. In case multiple zone indicates OPEN
LCD alternately display the massage with zone no.
SHORT : In case of zone line/detector Short LCD Display the information of respective zone with single
YELLOW LED glow. Normally these LED are OFF state. In case multiple zone indicates SHORT
LCD alternately display the massage with zone no.
PA SYSTEM & SELECTOR
1) SELECTOR INDICATION:- LED mounted with selector switch indicates the status of selector switch.
2) SELECTOR SWITCH :-These are used for announcement in zone wise / area selection. Each switch
select specific speaker/speakers for announcement.
3) ALL-CALL:-This single switch on all speaker simultaneous.
POWER INDICATION
1) SYSTEM ON
2) CHARGING
3) AC FAIL
4) BATTERY LOW
5) FUSE

RESET :-This switch has provided for restarting the system after any event or function .
SILENCE :-Whenever any signal comes from field’s device , the external buzzer beeping
with the information on LCD of respective zone . To mute that audio alarm
press silence button or in case of fire the hooter sound can be muted by pressing
this button.
LAMP TEST:-To check the LED in healthy position press this switch . All LED will be glow
with the buzzer sound .
EVACUATE : This switch used for common hooter activation . All common hooters alarming By
pressing this switch. When needs evacuation of building in fire emergency this switch
is used .
WALK-TEST: This switch is provided common for all zone. It is maintance purpose switch. This
switch disable hooter for 15 minute. At that 15 minute period detector & call point
will activated without alarming the hooters. This is used for one man test purpose . After
15 minute system goes automatically in normal state.
ZONE TEST: This switch is provided common for all zone. It TEST all zones one by one in
sequence FIRE, OPEN, SHORT .
SHORT: This switch is provided common for all zone. It works with the combination of TEST
switch. If we press TEST switch & SHORT simultaneously then short condition will
occur in that zone.
CONTROL

-
ZONE-3 +
-
ZONE-4 +
-
ZONE-5 +
-
ZONE-6 +
-
ZONE-7 +
-
ZONE-8 +
-
HTR-1 +
-
HTR-2 +
-
HTR-3 +
-
HTR-4 +
-
HTR-5 +
-
HTR-6 +
-
HTR-7 +
-
COM
HTR
C
FIRE
NO NC
RELAY
ZONE LINE For Detector & Manual Call Box Connection
+
-
24V
+
-
HTR-8
HOOTER(D.C.)
HOOTER
CUM SPEAKER
+
-
ZONE-1 +
-
ZONE-2 +C
FAULT
NO NC
RELAY
Terminal Connection Diagram
HOOTER LINE FOR Announcement Cum Hooter
5
ZONE-1 TO ZONE-8 Connector :-
These are the input terminal to connect the manual call box & DETECTOR. In case of smoke detected or glass
break at any manual call box then system provide 100volt A.C. to respective hooter & potential free contact
changes it state .Be sure for EOL at appropriate point for right function of manual call box.
HTR-1 to HTR-8 :-
In announcement case HTR-1 to HTR-8 provide out put to speaker as 100volt.
HTR-1 to HTR-8 are operate by selector switch -1 to HTR-1 manner.So this panel work both hooter &
public address system.This panel also act for conducting further operation for air handling unit or BMS use etc.
other associated gadgets. Be sure for EOL at appropriate point for right function of manual call box.
short circuit of HTR line can damage the product.
COMMON ANNOUNCEMENT SPEAKER:-
This terminals provide 100A.C. Output .Connecting LMT type HTR with this terminal provide direct output of
hooter our sound.
COMMON HOOTER:-
This terminals provide output 24 D.C. in case of fire from any zone line.
FIRE POTENTIAL FREE CONTACT :-
These are relay contact that change over its position in case of fire either it is multi zone or single zone.
FAULT POTENTIAL FREE CONTACT :-
These are relay contact that change over its position in case of fault either it is cross zone or single zone.
+
-
100V
COMMON
Announcement
SPEAKER
COMMON

OPERATING VOLTAGE : 24 DC+ 10%
MAINS SUPPLY : 230V AC 190V AC
STAND BY SUPPLY : 24V/4.5Amper
HOOTER OUTPUT : 24V/2Amax
RELAY RATING : 24V/3Amp
POTENTIAL FREE CONTACT : FIRE & FAULT
VOLTAGE CHARGER : 26.6V
ZONE POWER NORMAL : 15.6MA/ZONE
ALARM CURRENT : 35MA ZONE
AC FUSE RATING : 500MA
DC FUSE RATING : 6 Amp
BATTERY FUSE RATING : 6Amp
DIMENSIONS : (420X325X120)MM.
WEIGHT : 10 KG APPROX..
TECHNICAL DATA
6


WARRANTY CERTIFICATE
Dear Customer ,
Your NATIONAL SECURITY DEVICE Fire alarm system is
guaranteed against manufacturing defects of parts and component for a
period of 12 months from the date of
purchase______________________________
During this period any items found defective will be repaired at
our works or though service center.
Terms & Condition :
1) Serial o. Sticker should not be broken / tempered / mismatch
. as our record.
2) Product not used as per described guideline or hassling with
electronic part.
Serial No :
Stamp :
NATIONAL SECURITY DEVICES
NATIONAL
SECURITY DEVICES
8

TEST REPORT
..............MANUAL ALARM CONTROL PANEL ................... SPARE
ZONES .......................
CONTRACTOR NAME :
CLIENT /SITE :
BILL NO. / CHALLAN NO :
QUANTITY :
SERIAL NO. :
AC FUSE : .5 AMP
DC FUSE : 6 AMP
FIRE CONDITION : SYSTEM OK
FAULT CONDITION : SYSTEM OK
FIRE & FAULT RELAY : SYSTEM OK
DETECTION & HOOTER LINE : SYSTEM OK
This is to certify that the manual alarm control panel Supplied as
per detail has been manufactured by NATIONAL SECURITY DEVICE
at Delhi -92 .Test producer are conducted as per guideline by costumer.
Although all products tested as per IS:2189 stranded.
Test Report No . ERTL
It is again certified that all the featured laid down in the panel as
per customers specification have been provided and checked .
Date of Testing :
Date of Issued : Q. C. MANAGER
Client Copy
(N)/90 (4)-2K 7/Q0094 dated 14 May 2007.
9

Dealers Name & Address
Model No : Manual alarm control
SR No :
Sale date :

OFFICE
WORKS
PHONE
TELEFAX
MOBILE
E Mail
Website
: 485/14, SARPANCH KA BARA, MANDAWAL
FAZALPUR, DELHI-110092
: 2-A, Patparganj, Mayur Vihar,Phase - 1, Delhi - 110091
: 011 - 22751020, 6460359 9
: 011 - 22751020
: 09891222660,
: E-mail : [email protected]
: www.agnialarms.com
S
e
c
u
rit
y
D
e
v
i
c
e
s
This manual suits for next models
1
Table of contents
Popular Fire Alarm manuals by other brands

Eaton
Eaton SQUASHNI MICRO Technical data

Tiras
Tiras AM-MULTI+ Passport

Notifier
Notifier UZC-256 manual

Global Fire Equipment
Global Fire Equipment MPX-SNDR-DG - 4 V2 manual

Advanced
Advanced MxPro5 5000 Series product manual

Plumis
Plumis Automist Smartscan Hydra Installation, operation and maintenance manual