dn-3404:b • 11/17/09 — Page 1 of 2
UZC-256
Universal Zone Coder
Software Release 2.0
Annunciator Control Systems
dn-3404:b • D-140
General
The UZC-256 Universal Zone Coder enables the Notifier intel-
ligent fire alam control panels (FACPs), network control annun-
ciators (NCAs) and compatible legacy systems to provide
positive non-interfering successive zone coded outputs. Up to
256 separate codes may be programmed to operate on the
three coded outputs. Each output is used to code or pulse up
to 3 Amps of Notification Appliance power.
Features
• Coded output from the UZC-256 can be fed to multiple out-
put circuits.
• Up to 256 individually programmed codes.
• Three 3-Amp outputs.
• Programmable rounds of code (1 to 99 rounds).
• Up to four digits per round.
• Up to 15 pulses per digit of code.
• Optional general alarm.
• Programmable code and round(s) delay.
• Programmable pulse and digit pause times.
• Connects and communicates over panel EIA-485 interface.
• Programmable for California code.
• Weight 1.75 lbs.
Release 2.0 Features
• Secondary UZC use: counting alarm operation activates
UZC relays after specified number of alarms.
• Programmable address EIA-485 range (1-32).
• No code/counting selection for non-fire points.
Applications
The UZC-256 provides three outputs that supply unique coded
information to certain output circuits, depending on the alarm
initiation condition. This can be useful when employing coded
outputs in floor-above, floor-below applications, or to provide
various numbers of rounds for bell circuits and strobe or lamp
circuits.
NOTE: Due to the nature of coded outputs, the UZC-256 is not
compatible with notification devices which do not produce a steady
or non-periodic sound. Periodic appliances that produce their own
code (such as some codes available with electronic sounders) will
not be compatible with the UZC-256. Refer to the UZC-256 Instal-
lation Manual for a list of compatible panels.
Construction & Operation
The UZC-256 provides three coded output relays, each rated
for three amps at 30 VDC. These relays are controlled by a
predefined program, and can be set to respond to general
alarm conditions with the fire alarm system.
The UZC-256 and the CPU use the EIA-485 circuit for commu-
nication. When installed, the zone coder has a programmable
address on the EIA-485 interface.
Assignment of points to zone codes within the UZC-25 is pro-
grammable in the NFS2-3030, NFS2-640, NFS-320 and NCA-
2 (see programming manuals for details).
Electrical Specifications
Standby current: 35 mA.
Alarm current: 55 mA.
Installation
Locate the system, including components and peripheral
equipment in the following nominal environment:
Temperature: 60° to 80°F (15.6° to 26.7°C).
Relative humidity: 40% to 60% (non-condensing).
Agency Listings and Approvals
In some cases, certain modules or applications may not be
listed by certain approval agencies, or listing may be in pro-
cess. Consult factory for latest listing status.
•UL Listed: S624
•ULC Listed: CS118/CS733/CBP696
•MEA: 289-91-E Vol. III; 290-91-E Vol. III; 291-91-E Vol. II;
17-96-E; 345-02-E; 232-06-E
•CSFM: 7165-0028:141; 7165-0028:144; 7165-0028:157;
7165-0028:181; 7165-0028:214 (NFS-640); 7165-0028:224
(NFS-3030); 7170-0028:153; 7170-0028:154; 7170-
0028:182; 7170-0028:216 (NFS-640); 7170-0028:223
(NFS-3030, NFS2-3030), 7165-0028:243 (NFS2-640)
•FDNY: COA #
•Lloyd’s Register: 93/60/40 (E2) (AM2020/AFP1010)
•FM Approved
UZC-256 Universal Zone Coder
0704uzc.wmf
Page 2 of 2 — dn-3404:b • 11/17/09
NOTI•FIRE•NET™ is a trademark of Honeywell International Inc, IBM® is a
registered trademark of IBM Corporation.
©2006 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.
UZC-256 Programming
Programming the UZC-256 is accomplished through the serial port of an IBM®-compatible PC. The Software Interface (UZC-SI)
enables the user to select from a variety of code options (see software coding). The UZC requires power from the control panel to
download the programmed code. Alternately, it may be powered “remotely” with a 9 VDC power transformer which is included
with the UZC Hardware Interface (UZC-HI).
UZC Software Coding
Each code (up to 256) may be up to four digits long and each
digit can be from 0 to 15 pulses. User-selectable times and
delays may also be programmed.
Delay Time: The period from when the alarm is received at
the control panel and the code begins. Value can be 0 to 99
seconds.
Number of Rounds: The number of times the code will
sound. Value can be 1 to 99.
Pulse Time: The period each pulse will sound. Value can be
0 to 1 second in 1/100th of a second increments.
Digit Pause: The pause between digits of the code. Value
can be 0 to 10 seconds in 1/10th of a second increments.
Pulse Pause: The pause between pulses of the digit. Value
can be 0 to 1 second in 1/100th of a second increments.
Round Pause: The pause between the round(s) of the code.
Value can be 0 to 10 seconds in 1/10th of a second incre-
ments.
General Alarm: Provides the UZC with the capability to turn
on selected Indicating Circuits (general alarm) after complet-
ing its code. See the appropriate installation manual for infor-
mation on the “General Alarm” feature.
Product Line Information
UZC-256: Universal Zone Coder, power cable and mounting
hardware.
UZC-SI: UZC-256 Software Interface Version 2.0 (must be
used with UZC-256 EPROM 73712 or greater). Provides the
capability to program the UZC. Includes programming instruc-
tions and programming software.
UZC-HI: UZC-256 Hardware Interface. Includes null modem
cable, 9-pin to 25-pin adapter, and a 9 VDC power transformer.
BB-UZC: Backbox for housing the UZC for applications where
the UZC will not fit in the panel enclosure. Black casing.
BB-UZC-R: same as BB-UZC, but with a red casing.
75100: Power Harness. Order when mounting the UZC-256 in
the BB-17 (System 500 applications).
IBM® Compatible PC UZC-256
3404pc.wmf
0704uzc.wmf

Other manuals for UZC-256

1

Other Notifier Fire Alarm manuals

Notifier NBG-12LX User manual

Notifier

Notifier NBG-12LX User manual

Notifier AM2020 User manual

Notifier

Notifier AM2020 User manual

Notifier NFS-3030/E Owner's manual

Notifier

Notifier NFS-3030/E Owner's manual

Notifier LCD-80F User manual

Notifier

Notifier LCD-80F User manual

Notifier FS-WST Instruction Manual

Notifier

Notifier FS-WST Instruction Manual

Notifier 1010 User manual

Notifier

Notifier 1010 User manual

Notifier AM2020 User manual

Notifier

Notifier AM2020 User manual

Notifier VGM NION UniNet 2000 User manual

Notifier

Notifier VGM NION UniNet 2000 User manual

Notifier RP-1001 User manual

Notifier

Notifier RP-1001 User manual

Notifier UniNet 2000 AFP-300 NION User manual

Notifier

Notifier UniNet 2000 AFP-300 NION User manual

Notifier ID50 SERIES Instruction Manual

Notifier

Notifier ID50 SERIES Instruction Manual

Notifier NFS-640 User manual

Notifier

Notifier NFS-640 User manual

Notifier NBG-12LO User manual

Notifier

Notifier NBG-12LO User manual

Notifier NFS-640 Owner's manual

Notifier

Notifier NFS-640 Owner's manual

Notifier IFS-2600 Technical manual

Notifier

Notifier IFS-2600 Technical manual

Notifier NFS2-3030 User manual

Notifier

Notifier NFS2-3030 User manual

Notifier NBG-12S User manual

Notifier

Notifier NBG-12S User manual

Notifier AFP-2800 User manual

Notifier

Notifier AFP-2800 User manual

Notifier UZC-256 User manual

Notifier

Notifier UZC-256 User manual

Notifier INERTIA-2464/64 User manual

Notifier

Notifier INERTIA-2464/64 User manual

Notifier 002-439 Instruction Manual

Notifier

Notifier 002-439 Instruction Manual

Notifier ID50 SERIES User manual

Notifier

Notifier ID50 SERIES User manual

Notifier ONYX Series User manual

Notifier

Notifier ONYX Series User manual

Notifier CAB-5 Technical manual

Notifier

Notifier CAB-5 Technical manual

Popular Fire Alarm manuals by other brands

FireClass Precept EN13 Installation & commissioning manual

FireClass

FireClass Precept EN13 Installation & commissioning manual

Honeywell NOTIFIER IFS-2600 Technical installation manual

Honeywell

Honeywell NOTIFIER IFS-2600 Technical installation manual

Vighnaharta GDS-24-2 User and installation manual

Vighnaharta

Vighnaharta GDS-24-2 User and installation manual

Aritech 2X-AF2-FB-PRT-P Operation manual

Aritech

Aritech 2X-AF2-FB-PRT-P Operation manual

Teletek electronics SensoIRIS BSOU Installation instruction

Teletek electronics

Teletek electronics SensoIRIS BSOU Installation instruction

Panasonic EBL128 user manual

Panasonic

Panasonic EBL128 user manual

Wheelock MT4-115 installation instructions

Wheelock

Wheelock MT4-115 installation instructions

Fike 68-140 Installation and maintenance instructions

Fike

Fike 68-140 Installation and maintenance instructions

Simplex 4190 Installation and instructions

Simplex

Simplex 4190 Installation and instructions

Tiras AM-IN4 Passport

Tiras

Tiras AM-IN4 Passport

C&S YA60BD Operating and installation instructions

C&S

C&S YA60BD Operating and installation instructions

FireClass FC430SB quick start guide

FireClass

FireClass FC430SB quick start guide

Det-Tronics UVIR Series instructions

Det-Tronics

Det-Tronics UVIR Series instructions

Kidde Scorpio CPD 7051 Series Installation, operation & maintenance manual

Kidde

Kidde Scorpio CPD 7051 Series Installation, operation & maintenance manual

Channel Safety Systems Rapidfire instruction manual

Channel Safety Systems

Channel Safety Systems Rapidfire instruction manual

Ziton ZR432-2P Installation sheet

Ziton

Ziton ZR432-2P Installation sheet

Araani FireCatcher user manual

Araani

Araani FireCatcher user manual

Cooper Notification E70-24MCW Series installation instructions

Cooper Notification

Cooper Notification E70-24MCW Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.