
Pushbutton Lockout (CV556):
On some layouts it may be desirable to disable operation of the local control
pushbuttons. Setting CV556 to a value of 1 prevents operation of all the decoder
outputs by the optional Button Board pushbuttons. Setting CV556 to 0 enables
operation of these buttons. You can disable or enable ALL decoders on the layout at
the same time by using the accessory decoder broadcast address of 2044 when
programming CV556. CV556 is “global” to the Switch8-Mk2, meaning it will lockout all
button inputs from the button board. (Factory default = 0)
Notes on CV556:
CV556 should be programmed via Accessory Ops mode programming to the address of
output 1 only.
CV556 is not ‘sticky’. The decoder will not rmember that CV556 was programmed the
next time the layout is powered up.
Output On Time:
The ‘On Time’ or time that the output is active can be controlled for each output
individually. Occasionally you will an especially free throwing switch machine that will
travel all the way to the mechanical stop on the machine then bounce back away from
the stop. This means that the decoder is throwing the machine with too much energy.
By controlling the time that the output is activated we can control how much energy is
transferred from the decoder to the switch machine. The factory default value for this is
100mS which is usually satisfactory. If you find you need more or less energy you can
program the decoder (in increments of 4mS or 4/1000s of a second). CV577 through
CV580 are used to control the time. A value of 25 = 100mS (default) higher or lower
values may be programmed. Programming the CV=0 will cause the output to remain
on until the turnout is thrown to the opposite position.
CV577 - On time for output 1 (100mS = value of 25 default)
CV578 - On time for output 2 (100mS = value of 25 default)
CV579 - On time for output 3 (100mS = value of 25 default)
CV580 - On time for output 4 (100mS = value of 25 default)
Factory reset:
To reset the QSnap to original factory setting program CV8 to 8. A reset will only be
performed if you program CV8=8 via Accessory OPs mode programming to the
address of output 1.
Upon reset all settings will revert to the factory default setting as indicated below.
Factory default values for decoder
The Switch8-MK2 is factory programmed to the following values
Output 1 = accessory address 1
Output 2 = accessory address 2
Output 3 = accessory address 3
Output 4 = accessory address 4
CV548 is set to 0 (normal dual pushbutton operation by the optional Button Board)
CV556 is set to 0 (pushbutton lockout not engaged)
CV561 is set to 0 (normal output polarity)
CV562 is set to 0 (normal output polarity)
CV563 is set to 0 (normal output polarity)
CV564 is set to 0 (normal output polarity)
CV577 is set to 25 (100mS on time)
CV578 is set to 25 (100mS on time)
CV579 is set to 25 (100mS on time)
Last revised: 7 October 2014 Copyright 2014 NCE Corp Page5