Neilsen CT2129 User manual

3-IN-1 STUD CENTER FINDING, METAL
AND AC LIVE WIRE DETECTOR
CT2129
Ref no. TH210
INSTRUCTION MANUAL
IMPORTANT:
These instructions accompanying the product are the original instructions. This
document is part of the product, keep it for the life of the product passing it on to
any subsequent holder of the product. Read all these instructions before
assembling, operating or maintaining this product.
Cannon Tools Limited
Address: 20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K.

EC DECLARATION OF CONFORMITY
We CANNON TOOLS LTD
20 Station road, Rowley Regis, West Midlands,B65 0JU.U.K.
Declare that the following machine complies with the appropriate basic safety
and health requirements of the EC Directive based on its design and type, as
brought into circulation by us.
In case of alteration of the machine, not agreed upon by us, this declaration will
lose its validity.
Product description: 3-IN-1 STUD CENTER FINDING, METAL AND AC LIVE
WIRE DETECTOR
Model: CT2129 (Ref no. TH210)
Applicable EU Directives:
EC Directive of Electromagnetic Compatibility 2014/30/EU
Harmonized standards
EN 61326-1:2013
20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K.
Mr. Gurcharan Tony Singh Sanghera
Managing Director
CANNON TOOLS LTD
2020-08-04

1. SPECIFICATION
Detects wood and metal stud up to 1-1/2" (38mm)
Detects metal rebar up to 3" (76mm)
Detects AC live wire up to 3" (76mm)
Operating temperature / humidity: 0
o
Cto 40
o
C
Power supply: DC 9V (battery included)
Warning: Wear approved safety glasses and ear defenders.
2. IMPORTANT SAFETY INFORMATION
a). Read the instruction manual fully. Do not attempt any operation until you have
read and understood this manual.
b). Most important you must know how to safety start and stop this machine,
especially in an emergency.
c). Do not overload or misuse the tool. All tools are designed for a purpose and
are limited to what they are capable of doing. Overloading a tool will result in tool
failure and user injury.
d). Maintain your tools correctly. A well maintained tool will do the job safely.
Replace any damaged or missing parts immediately with original parts from the
manufacturer.
3. TECHNICAL DESCRIPTION
1. The Center Pointing System
2. Stud Mode Indication
3. Metal Mode Indication
4. AC Mode Indication
5. AC Wire Warming
6.1/2" Scan Mode Indication
7.1" Scan Mode Indication
8.11/2" Scan Mode Indication
9. Power Button
10. Mode Button
11. Scan Button
12. Battery (Back of unit)

4. UNPACKING AND CHECKING
Carefully remove the product from the packaging and examine it for any sign of
damage that may have happened during shipping. Lay the contents out and
check them against the parts shown below. If any part is damaged or missing;
please contact the seller and do not attempt to use the product .
5. USING THE TOOL
5.1. MODE SELECTION
When scanning for studs, there are three scan modes to choose
for properly thick of the scanning surface:
1/2" Scan Mode scans through surfaces up to 1/2 inch thick.
1" Scan Mode scans through surfaces up to 1 inch thick.
1-1/2" Scan Mode scans through surfaces up to 1-1/2 inch thick.
If the thick of the scanning surface is unknown, you can start with 1-1/2"
Scan Mode. And then choose more suitable Scan Mode to verify the
centre of studs again.
When scanning for metal pipes or rebar, select Metal Mode.
When scanning for electrical wires, select AC Mode.
5.2 HOW TO USE
IMPORTANT OPERATING TIPS,PLEASE READ CAREFULLY
Tool Position: For proper use, always place scanner flat against the surface
before turning on power.

Power: Depress and hold in the Scan button continuously while in use.
Calibration: Place unit flat on wall. Press and hold the Scan button. Do not
move the unit until calibration is complete (1-2 seconds). When calibration is
complete, the unit will sound a short beep and the bars will be cleared.
Operation: Move the unit slowly, while keeping it flat against the wall. Do not
rock or lift it.
5.3. SCANNING IN STUD MODE
After calibrating (see2), continue to hold the scan button and slowly
slide the unit across the surface. As you approach the edge of a stud,
bars on the display will indicate you are getting close. Continue moving the
scanner slowly until the display indicates the EDGE of the stud, (see the picture
below).
Continue moving the scanner slowly. The audio signal and display
will indicate the CENTER of the stud.
Continue in the same direction to find the other edge.
5.4. SCANNING IN METAL OR AC MODE
AC Wire Warning
Always verify the unit is in good working order before use.
You can test it in a known correctly wired socket or distribution board.
For your safety, AC Wire Warning works continuously in all modes.
When AC voltage is detected, the icon will be displayed on screen.
Caution: Wires deeper than 2in.(51mm),in conduit, or behind plywood
shear wall may not be detected. Use extreme caution under these
circumstances or whenever hot AC wires are present. Always turn off power
when working near electrical wires.
Select mode. After calibrating (see 2), continue to hold the scan button and

slowly slide the unit across the surface. Mark the spot where the display bars
peak and a steady tone sounds. Continue in the same direction until display bars
reduce.
Reverse direction and mark the spot where the display bars peak from
that direction. The midpoint of the two marks is the approximate center of the
object, (see the picture below)
6. CHANGING THE BATTERY
Press battery door release down with your finger or a coin and remove door.
Connect 9-V battery to cable and place inside.
Replace battery door and snap shut.
7. DISPOSAL
At the end of the machine's working life, or when it can no longer be repaired,
ensure that it is disposed of according to national regulations.
Contact your local authority for details of collection schemes in your area.
In all circumstances:
Do not dispose of this tool with domestic waste.
Do not incinerate.
During decommissioning of the equipment, certain hazards should be
understood and avoided:
Only with the line pressure released shall the equipment be disassembled.

8. EXPLANATION OF SYMBOLS
WARINING!
First read the instruction manual.
Wear safety glasses and ear protection.
Wear insulating gloves.

CANNON TOOLS LTD
Add: 20 station road, Rowley Regis, west midlands,B65 0JU.U.K.
Made in China
This manual suits for next models
1
Table of contents
Popular Security Sensor manuals by other brands

United Technologies
United Technologies Interlogix DDI602U-F1 Installation sheet

Powerfix Profi
Powerfix Profi 288019 Operation and safety notes

Visonic
Visonic K-940 installation instructions

ST Quadrat
ST Quadrat LUX-top GBD-RR 465 installation instructions

Haws
Haws 7501 Nstallation, operation & maintenance instructions

Hamamatsu
Hamamatsu C11202 Series manual