Nelson-Jameson Clean Logix BLX-600 User manual

USER
MANUAL
English (Original Instrucons)
Updated: 02/11/21
MODEL:
BLX-600
Compact Boot Scrubber

BLX-600 User Manual Page 2 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
!WARNING:
1. All personnel using this unit must be familiar with
the informaon contained in this manual. Follow all
installaon and maintenance instrucons.
2. Always wear appropriate footwear. Secure or remove
loose items on footwear.
3. Ensure solid foong and use both hands when operang
the unit.
4. Avoid contact of chemicals with skin and eyes. If contact
occurs, see MSDS sheet for further rst aid measures.
5. Follow safety instrucons of chemical manufacturer
(MSDS).
6. Always follow plant and OSHA guidelines about the use
of equipment.
7. Disconnect power before servicing equipment.
8. Always follow safety precauons and obey warning
labels. Failure to do so could result in injury or death.
Table of Contents
System Requirements
Installaon
Physical Set-Up
Plumbing Connecons
Motor Speed Adjustment
Operaon
Start Up
Use
Shut Down
Cleaning
Removing Brushes
03
04
05
06
07
07
07
08
Advanced Conguraon
Motor Current Sensor
Brush RPM Adjustment
Drive Parameters
Timing Relay
Maintenance
Troubleshoong
Appendices
Parts Callouts
Electrical Schemacs
Venturi System
09
09
10
10
11
12
14
20
22

BLX-600 User Manual Page 3 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Water Supply
• Flow: 5 GPM (3.8L/m) minimum*
• Pressure: 35-50 psi (207-414 kPa)**
• Temperature: 40-100⁰F (4-38⁰C)
3/8" supply piping size recommended
*Minimum pressure must be maintained during
specied water ow!
**For consistent operaon of Venturi Injector and
spray nozzles, a water pressure regulator and lter is
recommended.
Electrical
• BLX-600 (120V):
• 120 VAC Single Phase
• 60 Hz 15 Amps
• Supplied with 8 . power cable with NEMA
5-15P plug
• BLX-600 (230V):
• 230 VAC Single Phase
• 60 Hz 15 Amps
• Supplied with 8 . power cable with NEMA
5-15P plug
The BLX-600 is a compact automated footwear
scrubbing unit built to accommodate 1 user at a me.
The included user manual contain installaon,
operaon, and maintenance instrucons for BLX-
600 units. For further support or informaon please
contact your sanitaon representave, manufacturer,
or Clean Logix technical support.
Overview
NOTE: Back ow prevenon must be installed
in the water line to this unit. Check local
codes to ensure proper installaon.
System Requirements
!
WARNING:
DO NOT EXCEED maximum water
temperature! Damage to brushes can result.
• Construcon: 304L stainless steel, UHMW,
Polypropylene
• Weight: 167 lb (75.75 kg)
• Dimensions: 24” x 25.5” x 46”
(66 x 52 x 116.8 cm)
• Water Consumpon: 1.5 GPM
(3.8 L/m)
• Minimum Chemical Diluon Rao: 1:230*
Cleaning Methods
See pages 8 for disassembly and cleaning instrucons.
For chemistry recommendaons:
Specicaons
*NOTE: Unit tested at 70°F using water with
30-50 psi injector inlet pressure.
!
WARNING:
DO NOT use ammable liquids (i.e. alcohol
based soluons or similar) without diluon.
Use Case Chemical Type
Organic Soils Chlorinated Alkaline or Alkaline based
foaming cleaner
Mineral Buildup Acid based foaming cleaner
NOTE: Chemistry used must be compable with
materials of construcon (listed above).

BLX-600 User Manual Page 4 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
NOTE: For xed installaons, area in front of electrical panel must be clear at least 36"
Installaon

BLX-600 User Manual Page 5 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Physical Set Up:
1. Set unit in desired locaon.
2. Aspects to consider when deciding on placement:
• Clearance for general use
• Locaon of drain
• Emergency exit paths or egress
• Access to control box
• Connecons for water and electricity
3. Use a level to make sure the unit is stable and
leveled in all direcons [Figure 5.1].
4. Connect unit to electrical supply.
Plumbing Connecons:
1. Connect water source to solenoid valve ng
inlet (located on the side of the unit). Fing is
3/8" [Figure 5.2].
2. Connect the soluon source to the hose barb of
the Venturi Injector (located aer water inlet)
using 1/4" PVC tubing [Figure 5.2].
3. If necessary, adjust the diluon rao using the
included metering ps and test [Figure 5.3].
• The smallest metering p is a yellow p with a
small tube aached [Figure 5.3]. This tube can
be trimmed to alter the diluon rao.
• Full length capillary tube results in a diluon
rao of approximately 1:670 at 30-50 psi water
inlet pressure.
• To adjust injector, turn the bypass screen
clockwise unl soluon ows at a desired
range.
Installaon
NOTE: To move the unit use a pallet jack or a
hi-lo to li from the boom. Pad the forks to
protect the nish. Fig. 5.1: Level and stabilize unit using a leveling device
Capillary
Tube
Addional
Metering Tips
Fig. 5.3: Metering Tips and Capillary Tube
Fig. 5.2: Water and Venturi Injector (soluon) inlets
NOTE: For metering p injecon ow rates
and other informaon see page 18.

BLX-600 User Manual Page 6 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Motor Speed Adjustment
The speed of the motor is controlled by a variable
frequency motor drive. As the drive decreases the
frequency of the motor, the RPMs decrease. The V.F.
drive displays the Hz. on a small display and the knob
next to it adjusts the Hz. The worm gear reducer has a
20:1 rao.
Default: 1750 RPM at 60 Hz.
To adjust the speed:
1. Open the control box.
2. Acvate the sensor to turn on the motor.
3. As the motor is spinning, the unit will display the
operang speed in Hz.
4. Turn the knob counter-clockwise to decrease the
Hz, therefore decreasing the RPMs. Turning the
knob clockwise will increase the RPMs [Figure 6.1]
5. Adjust the Hz. on the variable frequency drive to
the desired brush speed. The minimum frequency
is 15 Hz and the maximum is 60 Hz Clean Logix
recommends 70 RPM/48 Hz.
Installaon (connued)
!
DANGER:
Do not open control box during wash down
or cleaning. Only authorized personnel should
open the control box.
Speed
Adjustment
Fig. 6.1: PowerFlex 4M Variable Frequency Drive

BLX-600 User Manual Page 7 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Start Up
1. Verify installaon has been completed:
• Brushes and grate are secured
• Unit is plugged in and receiving power
• Water and soluon have been plumbed and
lines are open
2. Pull the E-STOP switch up to engage power, when
illuminated the unit has power [Figure 7.1].
Use
1. Using both hands, grasp the handrail to acvate
the sensor.
2. When acvated, the brush will begin to rotate and
the soluon/water will spray [Figure 7.2].
3. While maintain grip on the handrail, place one
boot in between the side brushes - allowing the
rotang brushes to clean by moving the boot to
make contact with hard to reach areas.
4. When complete, remove the rst boot and repeat
with second.
5. Once the user removes their hands the brushes
and sanizer will stop.
Shut Down
• Press the red E-STOP buon on the control box.
• Disconnect power and follow lockout-tagout
procedures as necessary.
Operaon
!
CAUTION:
When operang: always ensure solid foong
and use handrail for stability.
Fig. 7.2: Sensor locaon and brush rotaon
NOTE: Prior to placing footwear into the unit,
test that it is working properly by acvang
the sensor (wave hand in front of sensor).
Fig. 7.1: E-Stop illuminaon
Sensor

BLX-600 User Manual Page 8 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Removing & Replacing Brushes
1. Shut down the unit (see pg. 7).
2. Remove the two vercal brushes by unscrewing
the knobs at the top of each brush and liing
them up and o of their shas [Figure 8.1].
3. Remove the grate by liing up on the back
secon, away from its alignment bolts, and pull
the enre grate plaorm up and out of the tub.
4. Release the sole brush anchor by turning and
pulling the anchor lever out, away from the tub.
The lever is located on the side of the tub as
shown below:
5. Li the sole brush out of the tub by grabbing the
open end and liing up to clear the opposing drive
sha anchor [Figure 8.2].
6. Brushes can be washed individually in a COP tank
or wash machine.
7. The tub can be washed by convenonal means.
Cleaning Procedures
Fig. 8.1: Removing vercal brushes
NOTE: It is NOT recommended to use hot water
(over 120°F) to clean brushes.
Fig. 8.3: Removing soles brush
Fig. 8.2: Removing grate
LOCKED UNLOCKED

BLX-600 User Manual Page 9 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Motor Current Sensor
Automaon Direct ACS-200 Current Switch
The motor current sensor monitors the current draw
of the motor and will stop the motor if an over-torque
condion occurs.
To adjust the Set-Point:
1. 1-6A Seng (Jumper Removed)
2. Two loops of wire through sensor.
3. Turn trimpot counterclockwise at least 5 turns.
4. Turn trimpot clockwise for 3-1/2 turns.
5. Test and adjust accordingly in 1/8 turn
increments.
Advanced Conguraon Opons
!
DANGER:
Do not open control box during wash down
or cleaning. Only authorized personnel should
open the control box.
Brush RPM Formula:
The formula for calculang Speed in RPM from Drive
Frequency in Hertz is:
[Motor Nameplate RPM] x [Drive Frequency (Hz)]
÷ [Motor Nameplate Frequency (Hz)] ÷ [Gear
Reducon]
Example:
• Motor Nameplate RPM = 1750
• Motor Nameplate Frequency (Hz) = 60
• Gear Reducon = 20
• Drive Frequency (Hz) = 48
1750 x 48 ÷ 60 ÷ 20 = 70 RPM
The formula for calculang Drive Frequency in Hertz
from Desired Speed in RPM is:
[Desired Speed RPM] x [Gear Reducon] x [Motor
Nameplate Frequency (Hz)] ÷ [Motor Nameplate
RPM]
Example:
• Desired Speed in RPM = 70
• Gear Reducon = 20
• Motor Nameplate Frequency (Hz) = 60
• Motor Nameplate RPM = 1750
70 x 20 x 60 ÷ 1750 = 48 Hz
SET-POINT
Fig. 9.1: Current Sensor Sengs Idencaon
RANGE JUMPER

BLX-600 User Manual Page 10 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Advanced Conguraon Opons (connued)
Drive Parameter Sengs
Allen Bradley 4M Variable Frequency Drive
Timing Relay Sengs
Eaton TRL04
• Funcon: R (O Delay)
• Time Range: 1 sec.
Schneider Electric Magnecra
• Funcon: S (O Delay)
• Time Range: 1 sec.
Parameter
Number Descripon Seng Units
P102 Motor NP Hertz 60 Hz
P104 Minimum Freq 30 Hz
P105 Maximum Freq 60 Hz
P106 Start Source 2 N/A
P109 Accel Time 1 s
P110 Decel Time 2 s
t201 Digital In1 Sel 3 N/A
t221 Relay Out Sel 1 N/A
!
DANGER:
Do not open control box during wash down
or cleaning. Only authorized personnel should
open the control box.
FUNCTION
TIME RANGE
ADJUSTMENT RANGE
Fig. 10.2: Schneider Magnecra Seng Idencaon
FUNCTION
TIME RANGE
ADJUSTMENT RANGE
Fig. 10.1: Eaton TRL04 Seng Idencaon

BLX-600 User Manual Page 11 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
The following maintenance procedures are
recommended for normal use. Units which see a high
amount of use should be inspected more frequently.
Weekly:
• Check unit for proper sensor funcon and brush
rotaon.
• Ensure grate is secure and funconing properly.
• Inspect brushes for damage or wear. Check for
missing or deformed bristles.
• Inspect electrical cords and plumbing for
damage.
• Inspect and test funcon of emergency stop
switches.
Monthly:
• Check all fasteners to ensure they are ght.
• Ensure warning labels and decals are present
and in good condion.
• Inspect grate spring assemblies (M1896) and
spring balancer bearings (M1904, M1905) for
wear
• Inspect motors, gearboxes, and reducers for
signs of oil leakage.
• Inspect electrical enclosure for signs of water
intrusion.
• Inspect sensors for damage.
• Inspect moving parts for damage or wear.
Quarterly:
• Inspect structure for cracked welds or bent
components.
Gear Reducer:
• The gear reducer is supplied lled to capacity
with Mobil Cibus SHC 634 NSF H1 Food Grade
or equal synthec oil.
• The synthec lubricaon provided is good
for ambient temperatures -10°F - 105°F and
is compable with standard compounded
oil.
• Oil should be changed every 2 years (or 6,000
operang hrs.)
• Designed with a bladder type vent system:
• Consists of an internal bladder that
seals the oil chamber from the outside
environment at all mes - as pressure
builds, the bladder contracts keeping the
internal pressure to a minimum.
• Advantage: The internal oil chamber is
completely sealed, ensuring oil is not
released causing contaminaon in the
applicaon.
Motor:
• Inspect at regular intervals.
• Verify the mounng bolts and couplings to
ensure that they are ght and properly adjusted.
• Motor bearings are sealed and not
re-greasable.
• Bearings should be replaced approximately
every 5 years for 8 hr./day service.
Preventave Maintenance

BLX-600 User Manual Page 12 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Unit is leaking onto oor:
• Check to make sure all joints are sealed.
Verify water and soluon inlets are aached and
rmly in place.
Leaner Diluon Raos Required:
• Verify metering p is installed in the injector
chemical inlet hose barb
• Change the metering p for a more appropriate
size (see pg. 4 for further informaon)
• If the desired diluon rao sll cannot be
achieved pre-diluon of the chemical may be
necessary.
Venturi will not draw Chemical Soluon:
• Verify water supply is sustaining 30 psi at the
injector inlet while unit is running
• Elevate the chemical jug above the injector (a jug
hook is provided for this purpose)
• Verify spray nozzles are not clogged. The nozzles
supplied with the equipment are rated at 0.2GPM
@ 10psi (0.28GPM @ 20 psi)
• Ensure the sucon lter is not clogged, kinked or
obstructed in any way that would restrict ow.
Unit not operang & E-STOP not Illuminated:
• Verify unit is plugged in.
• Verify E-STOP is not pushed down.
• Verify main power going to the unit.
• Verify circuit breakers in the building have not
been tripped.
Unit not operang & E-STOP is Illuminated:
• Check sensor is operang properly and is
connected via orange M12 cable.
• Verify all physical connecons to the brushes are
in place.
• Restart unit by pushing down the E-STOP, waing
10 seconds, then turning the unit on again.
Unit will not spray:
• Verify water pressure at the inlet to the water (30
psi min.)
• Verify water and soluon lines are aached and
rmly in place
• Inspect spray nozzles for clogging.
• Verify that the orange LED light on the solenoid
valve connector illuminates when the brushes are
rotang.
Troubleshoong

BLX-600 User Manual Page 13 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
F004 Fault Code on Variable Frequency Drive:
• If unit is connected to a GFCI, verify its rangs
(class, mA restricons, etc.)
• Verify minimum frequency seng on VFD is set
between 15 to 20 Hz.
• VFD Parameter: P104 [Minimum Freq.]
• Manufacturer Default: 30 Hz.
• Set the lowest carrier frequency on the VFD
(lower carrier = less switching on/o)
• VFD Parameter: P446 [PWM Frequency]
• Manufacturer Default: 4.0 kHz.
• Minimum: 2.0 kHz.
Troubleshoong
F002 Fault Code on Variable Frequency Drive:
Cause: Power may have been cycled to the unit
while it was “ON”. To solve:
1. While power is sll applied, turn the unit “o”
by pushing down hard on the e-stop buon
2. Wait at least 5 seconds, then pull the e-stop
buon out again. DO NOT stand on the
walkway grate during this process.
3. The unit should now be ready for use.
Cause: If the brushes stop suddenly during normal
use and the fault is displayed, the Motor Current
Sensor set point may be too low. To solve:
1. Turn the set point adjusng screw clockwise ½
turn to raise the set point and re-test. NOTE: Clean Logix recommends Leviton's
GFI protecon device [# GFRBF-W]for
circumstances where the facility's original
GFCI plug is not applicable.
Please contact your equipment representave
or manufacturer for further support.
iMore Informaon?

BLX-600 User Manual Page 14 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Appendix A - Parts Callout : BLX-600

BLX-600 User Manual Page 15 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Appendix A - Parts Callout : BLX-600
Part No. Descripon
F1000 STANDOFF 1/4 x 1/2 x 1/2 SS
F1001 Washer 3/4" X 1-1/4" X 1/16" PTFE
F1002 BEARING FLANGED 1/2' X 5/8' X 1/4' PTFE
F1017 BOLT HHC 10-32 x 1 1/4 SS
F1035 BOLT HHC 5/16-18 x 1/2 SS
F1040 BOLT HHC 5/16-18 x 1-1/4 SS
F1046 NUT HEX FLANGED 1/4-20 SS
F1047 NUT NYLOCK 1/4-20 SS
F1052 NUT NYLOCK 5/16-18 SS
F1054 WASHER 5/16 SS
F1056 WASHER 1/4 SS TYPE A
F1070 WASHER THIN 1/2 SS
F1078 WASHER .5 X .88 X .06 UHMW
F1083 BOLT HHC 1/4-20 x 1-1/4 SS
F1085 WASHER FENDER 5/16-18 SS
F1105 BOLT HHC 1/4-20 X 1/2 SS
F1106 STANDOFF #10 X 1/2 X 3/8 O.D. SS
F1119 WASHER 10 SS
M1000 TUB WELDMENT BLX-600-DAF
M1016 GRATE WELDMENT BLX-600
M1021 BRUSH SHAFT WELDMENT BLX-600
M1025 BRUSH, CYLINDER, 8" DIA. X 3" LONG, BLACK PP
FILAMENT
M1026 HORIZONTAL BRUSH BLX-600/800/1000 8"
DIAMETER, 6" WIDE
M1027 DRIVE SHAFT 1 WELDMENT BLX-600
M1030 Brush Coupler BLX-600
M1031 Drive Sha 2 BLX-600
M1032 Sha Latch BLX-600
M1033 SS MOTOR MOUNT A
M1034 SS MOTOR MOUNT B
M1057 BRUSH KNOB WELDMENT FEMALE
M1085 VERTICAL SPRAY BAR WELDMENT
M1134 SOLENOID BRACKET
M1135 SPRAY POLE BLX-600
M1136 PIPE SUPPORT POST
M1283 LATCH STUD THREADED
M1924 BLX GEN2 PANEL ASSEMBLY 400-600-800 - 115V
P1000 Right Angle Gear Box, 5/8" Hollow Input & Output
Shas, Right Hand Rotaon
P1005 SS MOTOR 1/2HP, 1800 RPM, 230/460/3/60,
TENV, 56C FOOTLESS
Part No. Descripon
P1006
STERLING GEAR REDUCER 20:1, 56C, HOLLOW
QUILL, .625 HOLLOW OUTPUT, 1.33" CENTER
DISTANCE,
P1041 Photo Eye, Allen-Bradley 42EF, 24VDC
P1046 VALVE, SOLENOID, 3/8" SS 24VDC DIN COIL,
DEMA 463PS.4D
P1047 VENTURI INJECTOR SS BODY & METER KNOB 3/8'
P1100 PIPE HEX NIPPLE 3/8 SS
P1101 PIPE BUSHING 3/8 x 1/4 SS
P1102 PIPE NIPPLE 1/4 CLOSE SS
P1103 PIPE TEE 1/4' NPT SS
P1104 PIPE ELBOW 1/4 x 90 SS
P1105 Pipe Union, Female , 1/4' NPT
P1106 PIPE NIPPLE 1/4 x 2-1/2 SS
P1147 CORD GRIP 1/2 NPT X .170-.450 BLK HEYCO
M3231
P1148 CORD GRIP NUT 1/2" NPT BLACK - HEYCO 8463
P1184 CORD GRIP 1/2 NPT X .095-.260 BLK HEYCO
M4518
P1186 KNOB 1-1/2 x 5/16-18 THREADED HOLE SS
60205K68
P1187 SOLENOID CABLE 18MM DIN 24V LED 3M SC18-
LS24-3
P1188 PIPE HEX NIPPLE 1/4 SS
P1197 WIRE SJOOW 14AWG 4 CONDUCTOR BLACK
(0.415 OD) 300V 01364.15T01
P1200 125V 15A 5-15 MALE PLUG
P1242 CRIMP ON TERMINAL, RING 1/4" ID, 14-16 AWG
INSULATED
P1449
Push-Pull Pushbuon, Red, 24V Direc Full Voltage,
22mm Mounng, LED, 2NC Contact Block, 12-
30VAC/DC Bulb
P1556 CRIMP ON TERMINAL, RING #10, 14-16 AWG
INSULATED
P1599 METERING TIP, CAPILLARY TUBE
P1677 SPLICE TERMINAL 10-16 AWG NATURAL
P1753 Right Angle Gear Box, 5/8" Hollow Input & Output
Shas, Le Hand Rotaon
P1769 METERING TIPS, ULTRA LEAN 100-15KU
P1828 WIRE, VFD-MOTOR, 14 AWG, 4-CONDUCTOR,
SHIELDED, XLPE/PVC
P1934 GREASE, ELECTRIC INSULATING .17OZ ONE TIME
USE PACK

BLX-600 User Manual Page 16 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Appendix A - Parts Callout : BLX-600-6

BLX-600 User Manual Page 17 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Appendix A - Parts Callout : BLX-600-6
Part No. Descripon
F1000 STANDOFF 1/4 x 1/2 x 1/2 SS
F1001 Washer 3/4" X 1-1/4" X 1/16" PTFE
F1002 BEARING FLANGED 1/2' X 5/8' X 1/4' PTFE
F1017 BOLT HHC 10-32 x 1 1/4 SS
F1035 BOLT HHC 5/16-18 x 1/2 SS
F1040 BOLT HHC 5/16-18 x 1-1/4 SS
F1046 NUT HEX FLANGED 1/4-20 SS
F1047 NUT NYLOCK 1/4-20 SS
F1052 NUT NYLOCK 5/16-18 SS
F1054 WASHER 5/16 SS
F1056 WASHER 1/4 SS TYPE A
F1070 WASHER THIN 1/2 SS
F1078 WASHER .5 X .88 X .06 UHMW
F1083 BOLT HHC 1/4-20 x 1-1/4 SS
F1085 WASHER FENDER 5/16-18 SS
F1105 BOLT HHC 1/4-20 X 1/2 SS
F1106 STANDOFF #10 X 1/2 X 3/8 O.D. SS
F1119 WASHER 10 SS
M1000 TUB WELDMENT BLX-600-DAF
M1016 GRATE WELDMENT BLX-600
M1026 HORIZONTAL BRUSH BLX-600/800/1000 8"
DIAMETER, 6" WIDE
M1027 DRIVE SHAFT 1 WELDMENT BLX-600
M1030 Brush Coupler BLX-600
M1031 Drive Sha 2 BLX-600
M1032 Sha Latch BLX-600
M1033 SS MOTOR MOUNT A
M1034 SS MOTOR MOUNT B
M1057 BRUSH KNOB WELDMENT FEMALE
M1085 VERTICAL SPRAY BAR WELDMENT
M1134 SOLENOID BRACKET
M1135 SPRAY POLE BLX-600
M1136 PIPE SUPPORT POST
M1283 LATCH STUD THREADED
M1618 BRUSH VERTICAL CYL 8 X 6
M1623 BRUSH SHAFT WLDMNT V-6
M1719 BRUSH SHAFT V-6
M1924 BLX GEN2 PANEL ASSEMBLY 400-600-800 - 115V
P1000 Right Angle Gear Box, 5/8" Hollow Input & Output
Shas, Right Hand Rotaon
P1005 SS MOTOR 1/2HP, 1800 RPM, 230/460/3/60,
TENV, 56C FOOTLESS
Part No. Descripon
P1006
STERLING GEAR REDUCER 20:1, 56C, HOLLOW
QUILL, .625 HOLLOW OUTPUT, 1.33" CENTER
DISTANCE,
P1041 Photo Eye, Allen-Bradley 42EF, 24VDC
P1046 VALVE, SOLENOID, 3/8" SS 24VDC DIN COIL,
DEMA 463PS.4D
P1047 VENTURI INJECTOR SS BODY & METER KNOB 3/8'
P1100 PIPE HEX NIPPLE 3/8 SS
P1101 PIPE BUSHING 3/8 x 1/4 SS
P1102 PIPE NIPPLE 1/4 CLOSE SS
P1103 PIPE TEE 1/4' NPT SS
P1104 PIPE ELBOW 1/4 x 90 SS
P1105 Pipe Union, Female , 1/4' NPT
P1106 PIPE NIPPLE 1/4 x 2-1/2 SS
P1147 CORD GRIP 1/2 NPT X .170-.450 BLK HEYCO
M3231
P1148 CORD GRIP NUT 1/2" NPT BLACK - HEYCO 8463
P1184 CORD GRIP 1/2 NPT X .095-.260 BLK HEYCO
M4518
P1186 KNOB 1-1/2 x 5/16-18 THREADED HOLE SS
60205K68
P1187 SOLENOID CABLE 18MM DIN 24V LED 3M SC18-
LS24-3
P1188 PIPE HEX NIPPLE 1/4 SS
P1197 WIRE SJOOW 14AWG 4 CONDUCTOR BLACK
(0.415 OD) 300V 01364.15T01
P1200 125V 15A 5-15 MALE PLUG
P1242 CRIMP ON TERMINAL, RING 1/4" ID, 14-16 AWG
INSULATED
P1449
Push-Pull Pushbuon, Red, 24V Direc Full Voltage,
22mm Mounng, LED, 2NC Contact Block, 12-
30VAC/DC Bulb
P1556 CRIMP ON TERMINAL, RING #10, 14-16 AWG
INSULATED
P1599 METERING TIP, CAPILLARY TUBE
P1677 SPLICE TERMINAL 10-16 AWG NATURAL
P1753 Right Angle Gear Box, 5/8" Hollow Input & Output
Shas, Le Hand Rotaon
P1769 METERING TIPS, ULTRA LEAN 100-15KU
P1828 WIRE, VFD-MOTOR, 14 AWG, 4-CONDUCTOR,
SHIELDED, XLPE/PVC
P1934 GREASE, ELECTRIC INSULATING .17OZ ONE TIME
USE PACK

BLX-600 User Manual Page 18 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Appendix B - Electrical Panel Parts Callout
Part No. Descripon
F1172 SCREW THEAD FORMING 10-32 X 1/2 HEX WASHER
HEAD ZINC
P1111 END STOP TERMINAL BLOCK
P1122 POWER SUPPLY 24VDC 60W
P1180 VARIABLE FREQUENCY DRIVE 0.5HP 120VAC
P1323 CIRCUIT BREAKER 10A SINGLE POLE
P1873 TERMINAL BLOCK SPRING CLAMP 5.1mm GRAY
P1874 TERMINAL BLOCK SPRING CLAMP 5.1mm GROUND
Part No. Descripon
P1875 TERMINAL BLOCK SPRING CLAMP 5.1mm DUAL-
LEVEL GRAY
P1877 TERMINAL BLOCK END BARRIER L3 SERIES
P1880 TERMINAL JUMPER 5.1mm
P1939 RELAY, TIMER, MULTIFUNCTION 24VDC (REPLACES
P1115)
P1940 SWITCH, CURRENT SENSING WITH TIME DELAY,
1-175A ADJUSTABLE, FIXED CORE, NC

BLX-600 User Manual Page 19 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
General
Installaon
OperaonAppendix Maintenance ConguraonTroubleshoong
Appendix B - Electrical Panel Parts Callout
Part No. Descripon
F1172 SCREW THEAD FORMING 10-32 X 1/2 HEX WASHER
HEAD ZINC
P1111 END STOP TERMINAL BLOCK
P1122 POWER SUPPLY 24VDC 60W
P1325 CIRCUIT BREAKER 13A DOUBLE POLE
P1347 VARIABLE FREQUENCY DRIVE 0.5HP 240VAC
P1873 TERMINAL BLOCK SPRING CLAMP 5.1mm GRAY
P1874 TERMINAL BLOCK SPRING CLAMP 5.1mm GROUND
Part No. Descripon
P1875 TERMINAL BLOCK SPRING CLAMP 5.1mm DUAL-
LEVEL GRAY
P1877 TERMINAL BLOCK END BARRIER L3 SERIES
P1880 TERMINAL JUMPER 5.1mm - 10 POSITION
P1939 RELAY, TIMER, MULTIFUNCTION 24VDC (REPLACES
P1115)
P1940
"SWITCH, CURRENT SENSING WITH TIME DELAY,
1-175A ADJUSTABLE, FIXED
CORE, NC"

BLX-600 User Manual Page 20 of 23 Updated: 02/11/21
USER MANUAL: BLX-600
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Appendix C - Electrical Schemac (120VAC)
Table of contents