5
MACHINE PREPARATION
BATTERY POWER LEVEL INDICATORS
The battery power level gage is located on the upper control panel. The gage has a series of LEDs to indicate the amount of power left in the
batteries. When the batteries have a full charge, all LEDs are lit. As the batteries are discharged, the LEDs will begin to go out from right to
left. To maximize the life of the batteries, do not allow the LEDs to go beyond the discharge level as described below.
To maximize the life of the batteries, only recharge the batteries when the machine is operated for a total of 30 minutes or more and always
recharge the batteries immediately after usage when LEDs are indicating charging is required as described below.
BATTERY POWER LEVEL INDICATOR - TRACTION DRIVE MODELS
The battery power level gage is located on the upper control panel. The gage has red, yellow and green
LEDs to indicate the amount of power left in the batteries.
On lead acid battery-equipped units, when the discharge level reaches the rst red LED, it is a good time
to nish your scrubbing application and recharge the unit. If you do choose to continue scrubbing, when
the last red LED begins to ash, the unit will shut down the brush motor but leave the vacuum and
traction drive operational to perform nal water recovery and transport back to storage. This function
not only serves as an indicator that your battery level has reached a point where recharging is required,
but also protects the batteries from being fully discharged.
AGM battery-equipped units should not be used after the last yellow LED goes out leaving only red
LEDs. Using the unit beyond this point can reduce the life of the batteries.
NOTE: The traction drive battery power level gage also displays fault codes. The LEDs will ash specic
fault codes if a fault is detected. See Troubleshooting section for LED fault codes.
Battery Level Indicator -
Traction Drive Models
BATTERY POWER LEVEL INDICATOR - PAD/BRUSH ASSIST MODELS
The battery power level gage is located on the upper control panel. The gage has a series of yellow
LEDs to indicate the amount of power left in the batteries. When batteries are fully charged, all LEDs are
lit. As the batteries discharge, the LEDs will begin to go out from right to left.
On lead acid battery-equipped units, when the discharge level reaches the last, lit LED (2nd in from left)
it is a good time to nish your scrubbing application and recharge the unit. If you do choose to continue
scrubbing, when last LED begins to ash, the unit will shut down the brush motor but leave the vacuum
operational to perform nal water recovery. This function not only serves as an indicator that your
battery level has reached a point where recharging is required, but also protects the batteries from being
fully discharged.
AGM battery-equipped units should not be used after there are only two LEDs lit. Using the unit beyond
this point can reduce the life of the batteries.
Battery Level Indicator -
Pad/Brush Assist Models
Recharge AGM
batteries
Recharge lead
acid batteries
Recharge AGM
batteries
Recharge lead
acid batteries