manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. New Pig
  6. •
  7. Household Appliance
  8. •
  9. New Pig AEROSOLV XL User manual

New Pig AEROSOLV XL User manual

The guide on the following page(s) was provided by the supplier.
New Pig Corporation assumes no responsibility, obligation, or
liability in conjunction with the use or misuse of the information.
AEROSOLV ®XL CA-Compliant
Can Puncturing System
Instructions for:
357495
One Pork Avenue
Tipton, PA 16684-0304 PIG, PIG logo are registered trademarks in USA and other countries. See tm.newpig.com
New Pig
newpig.com
North America: 1-800-468-4647 UK: 0800 919 900
Europe: +31 (0)76 596 92 50 Outside North America: +1-814-684-0101
China: +86-21-400 921 5178
*This is a quick-start guide and does not replace operations manual. Please refer to operations manual for detailed instructions and further information. RMP5134 Rev A ©2017 Aerosolv Incorporated
aerosolv AEROSOL
CAN RECYCLING
®
aerosolv
®
OPERATION
USING THEAEROSOLV SYSTEM:
WEAR SAFETYGOGGLES WHILE OPERATING AEROSOLV.
INSERT AEROSOL CAN
Insert aerosol can, NOZZLE END DOWN,
into housing sleeve, so that shoulder of
can rests on gasket. For 1” “mini-cans”,
push shoulder of can beyond gasket. Be
sure to remove cap from aerosol can prior
to insertion.
LOWER TOP PLATE
Lower the sliding top plate and FIRMLY
engage against plastic sleeve or bottom
of “jumbo” can. TIGHTEN lock knob.
PUSH HANDLE DOWN
Push handle down firmly until
completely depressed and HOLD IN
PLACE while can releases initial
pressure and contents. Allow the
contents of the can to drain into the
collection drum (about 20 seconds).
For safety, after removing the last
punctured can, lower sliding top to rest
on plastic sIeeve and tighten lock knob
to seal collection drum. For “jumbo”
cans, replace plastic sleeve prior to
lowering sliding top plate.
MAINTENANCE TIPS:
Thread into 2" bung, rotate
clock wise until ground support
plate firmly engages drum rim.
PUNCTURING UNIT
Thread directly to 3/4"
bung of drum.
FILTER
Attach ring terminal of Anti-
Static Wire to brass screw on
Ground Support Plate of
Puncturing Unit.
Attach other end of Anti-Static
Wire to any nearby confirmed
ground source, ex. metal pipe.
*OSHA requires that liquid
storage vessels be grounded
to prevent static.
ANTI-STATIC WIRE
Always operate outdoors or in a well ventilated area.
INSTALLATION
When puncturing “jumbo” cans, remove
white plastic sleeve from housing, then insert
can as pictured.
The first and only aerosol can recycling technology to be verified by
the joint U.S. EPA and California EPA Environmental Technology
Verification program (ETV).
aerosolv
®
PUNCTURING UNIT
•Periodic cleaning and lubrication of the puncture pin
will assure years of trouble-free use. With constant,
heavy usage, the puncture pin should be cleaned and
lubricated once a month.
To clean or replace puncture pin, remove bridge pin at
uppermost point of handle. Entire handle mechanism and
puncture pin can be removed.
• Gasket deterioration will occur when venting aerosol
paints and aggressive solvents, requiring periodic
gasket replacement. To assure proper seal during
usage, check gaskets frequently and replace as
required.
To replace gasket: remove plastic sleeve, pull out old gasket,
fold and insert new gasket, press into place.
FILTER
•Replace Activated Carbon Cartridge after every 750
cans punctured. Remove spent Activated Cartridge by
turning counter-clockwise while holding lower
Coalescing Cartridge in place.
• Replace entire lter every 9 months or after
puncturing 2250 spent aerosol cans.
*This is a quick-start guide and does not replace operations manual. Please refer to operations manual for detailed instructions and further information. RMP5134 Rev A ©2017 Aerosolv Incorporated
aerosolv AEROSOL
CAN RECYCLING
®
aerosolv
®
OPERATION
USING THEAEROSOLV SYSTEM:
WEAR SAFETYGOGGLES WHILE OPERATING AEROSOLV.
INSERT AEROSOL CAN
Insert aerosol can, NOZZLE END DOWN,
into housing sleeve, so that shoulder of
can rests on gasket. For 1” “mini-cans”,
push shoulder of can beyond gasket. Be
sure to remove cap from aerosol can prior
to insertion.
LOWER TOP PLATE
Lower the sliding top plate and FIRMLY
engage against plastic sleeve or bottom
of “jumbo” can. TIGHTEN lock knob.
PUSH HANDLE DOWN
Push handle down firmly until
completely depressed and HOLD IN
PLACE while can releases initial
pressure and contents. Allow the
contents of the can to drain into the
collection drum (about 20 seconds).
For safety, after removing the last
punctured can, lower sliding top to rest
on plastic sIeeve and tighten lock knob
to seal collection drum. For “jumbo”
cans, replace plastic sleeve prior to
lowering sliding top plate.
MAINTENANCE TIPS:
Thread into 2" bung, rotate
clock wise until ground support
plate firmly engages drum rim.
PUNCTURING UNIT
Thread directly to 3/4"
bung of drum.
FILTER
Attach ring terminal of Anti-
Static Wire to brass screw on
Ground Support Plate of
Puncturing Unit.
Attach other end of Anti-Static
Wire to any nearby confirmed
ground source, ex. metal pipe.
*OSHA requires that liquid
storage vessels be grounded
to prevent static.
ANTI-STATIC WIRE
Always operate outdoors or in a well ventilated area.
INSTALLATION
When puncturing “jumbo” cans, remove
white plastic sleeve from housing, then insert
can as pictured.
The first and only aerosol can recycling technology to be verified by
the joint U.S. EPA and California EPA Environmental Technology
Verification program (ETV).
aerosolv
®
PUNCTURING UNIT
•Periodic cleaning and lubrication of the puncture pin
will assure years of trouble-free use. With constant,
heavy usage, the puncture pin should be cleaned and
lubricated once a month.
To clean or replace puncture pin, remove bridge pin at
uppermost point of handle. Entire handle mechanism and
puncture pin can be removed.
• Gasket deterioration will occur when venting aerosol
paints and aggressive solvents, requiring periodic
gasket replacement. To assure proper seal during
usage, check gaskets frequently and replace as
required.
To replace gasket: remove plastic sleeve, pull out old gasket,
fold and insert new gasket, press into place.
FILTER
•Replace Activated Carbon Cartridge after every 750
cans punctured. Remove spent Activated Cartridge by
turning counter-clockwise while holding lower
Coalescing Cartridge in place.
• Replace entire lter every 9 months or after
puncturing 2250 spent aerosol cans.

Popular Household Appliance manuals by other brands

Hostess HT4020 manual

Hostess

Hostess HT4020 manual

AIC orium QUAELIS 10 user manual

AIC

AIC orium QUAELIS 10 user manual

elho BRUSSELS Instructions for use

elho

elho BRUSSELS Instructions for use

Prem-I-Air EH1586 manual

Prem-I-Air

Prem-I-Air EH1586 manual

Shoefresh Mini instruction manual

Shoefresh

Shoefresh Mini instruction manual

Cooper Instruments & Systems DPG 1600 user guide

Cooper Instruments & Systems

Cooper Instruments & Systems DPG 1600 user guide

emerio LR-114377.1 manual

emerio

emerio LR-114377.1 manual

Beautural 719NA-0001 quick start guide

Beautural

Beautural 719NA-0001 quick start guide

EcoGecko 75218 instruction manual

EcoGecko

EcoGecko 75218 instruction manual

BRIGHT 022932 Original instructions

BRIGHT

BRIGHT 022932 Original instructions

Patriot VOICE EZ user manual

Patriot

Patriot VOICE EZ user manual

Clas Ohlson 44-3793 Instructions for use

Clas Ohlson

Clas Ohlson 44-3793 Instructions for use

VEVOR HSTW-18 manual

VEVOR

VEVOR HSTW-18 manual

MOB MO2078 user manual

MOB

MOB MO2078 user manual

Ailoria TOUCHE II instruction manual

Ailoria

Ailoria TOUCHE II instruction manual

Fagor driron Installation and user manual

Fagor

Fagor driron Installation and user manual

Fusion 31006 Assembly instructions

Fusion

Fusion 31006 Assembly instructions

Itouchless IP02DSS user manual

Itouchless

Itouchless IP02DSS user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.