1|Product Overview
The NextCentury RR301 Remote Reader is an advanced meter reading
and transmitting device which provides a high visibility remote display
of up to two utility meters.
The Remote Reader has an attractive consumer design, making it an
ideal solution for apartment meter display requirements. The utility
and unit of measure are clearly displayed, ensuring an accurate
interpretation of the read.
The pre-installed battery provides up to 10 years of operation and is
field-replaceable.
The Remote Reader is compatible with virtually all modern encoded
and pulse-output utility meters including water, electric, gas, run-
time, and thermal meter models.
2|Packaging Contents
A RR301 Display Unit D Sheetrock Anchors (2)
B Mounting Plate E Mounting Screws (2)
C Security Seal Assembly
3|Specifications
3.1 – Dimensions:
● Display unit and mounting plate:
145mm x 117mm x 44mm | 5.7 in x 4.6 in x 1.7 in
● Mounting holes center to center: 88.4 mm | 3.5 in (Can
be installed on a standard single gang wall-box)
3.2 – Operation Environment:
● -20°C to 60°C | -4°F to 140°F
● Water-resistant for outdoor installation (Rating
information pending)
3.3 – Battery Life:
● Up to 10 years*
*Note: Typical battery life assumes constant operating temperatures are
between 70°F and 90°F. Battery life may be reduced with operation outside of
this range.
3.4 - Certifications:
FCC: Pending
NTEP: Pending
IC: Pending
IP-Rating: Pending
4|Meter Compatibility
4.1 – Pulse Output Meters
● Pulse output passive (reed switch, solid-state relay,
contact relay, open-drain)
● Pulse output active (voltage pulse up to 15v)
4.2 – Encoded 3-Wire Protocol
● Neptune (Including ProRead, ECoder, ProCoder meters)
● Sensus UI-1203 (Includes many meter models from
Sensus, Hersey/Mueller, Master Meter, Badger,
Kamstrup, and Zenner)
● K-Frame (Elster/AMCO)
5|Device Setup & Configuration
In-field configuration can be conducted by a technician using their
mobile device (iOS or Android) paired with the NextCentury Direct
Connect programming device (available separately). Device pre-
programming is also available.
6|FCC Part 15 and ISED Statement
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning

www.nextcenturymeters.com
V. 071819
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
The FCC requires the user to be notified that any changes or
modifications made to this device that are not expressly approved
by Company Name may void the user’s authority to operate the
equipment.
As per 47 CFR §15.19
(All other devices shall bear the following statement in a
conspicuous location on the device:
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
As per 47 CFR §15.21
The user’s manual or instruction manual for an intentional or
unintentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the
equipment. In cases where the manual is provided only in a form
other than paper, such as on a computer disk or over the Internet,
the information required by this section may be included in the
manual in that alternative form, provided the user can reasonably
be expected to have the capability to access information in that
form.
ISED Statement
This radio transmitter (identify the device by certification number)
has been approved by Industry Canada to operate with the antenna
types listed below with the maximum permissible gain indicated.
Antenna types not included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use
with this device.
Immediately following the above notice, the manufacturer shall
provide a list of all antenna types approved for use with the
transmitter, indicating the maximum permissible antenna gain (in
dBi).
8.4 User Manual Notice for Licence-Exempt Radio Apparatus
User manuals for license-exempt radio apparatus shall contain the
following text, or an equivalent notice that shall be displayed in a
conspicuous location, either in the user manual or on the device, or
both:
This device complies with Innovation, Science and Economic
Development Canada’s licence-exempt RSSs. Operation is subject to
the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme aux flux RSS exemptés de licence
d'Innovation, Science et Développement économique Canada.
L'opération est soumise aux deux conditions suivantes:
(1) Cet appareil ne doit pas provoquer d'interférence; et
(2) Cet appareil doit accepter toute interférence, y compris les
interférences susceptibles de provoquer un fonctionnement
indésirable de l'appareil.
--------------------------
ISEDC Radiation Exposure Statement
[English] Radiation Exposure Statement: This equipment complies
with the IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator
and your body.
[French] Énoncé d'exposition aux rayonnements: Cet équipement
est conforme aux limites d'exposition aux rayonnements ioniques
RSS-102 Pour un environnement incontrôlé. Cet équipement doit
être installé et utilisé avec un Distance minimale de 20 cm entre le
radiateur et votre corps.
7|Warranty/Disclaimer
Scope of Warranty
NextCentury warrants that all communication equipment
manufactured by NextCentury will be free from defects in materials
and workmanship under normal use and in accordance with
NextCentury’s documented installation and operating procedures for
a period of three (3) years from the date of manufacture.
Products not manufactured by NextCentury, including without
limitation, accessories, attachments, or batteries used in conjunction
with NextCentury equipment are warranted, if at all, only by the
original manufacturer. NextCentury’s warranties do not include
replacement of batteries used to power NextCentury products.
Limits of Liability
This warranty only applies to Read Management System components
produced by NextCentury, and does not cover any products which
have been damaged by misconduct, negligence, vandalism, acts of
God, excessive operating conditions, or unauthorized attachments or
modifications. This warranty will be nullified and voided if products
are placed in non-recommended installation application/fashion, or
are converted, altered, or treated by other than NextCentury
recommended procedures and instructions, or are read by equipment
not approved by NextCentury.

www.nextcenturymeters.com
V. 071819
NextCentury’s liability and customer’s exclusive remedy under this
warranty is expressly limited to repair or replacement of the product
at NextCentury’s option, and is conditioned upon the customer
returning the product(s) to the location designated by NextCentury
within the warranty periods or limits stated herein and pre-paying the
freight costs both to and from specified location. In no event shall
NextCentury be liable for costs or expenses associated with the
removal or installation of products under this warranty.
NextCentury shall have no liability or responsibility to the purchaser
or any third party for any loss, cost, expense, damage, or liability,
whether direct or indirect, or for special, incidental, indirect, or
consequential damages of any kind, regardless of whether such
liability is based on breach of contract, tort, strict liability, breach of
warranties, or otherwise, and even if advised of the likelihood of such
damages. Incidental and consequential damages include, but are not
limited to, lost revenue, loss of profits, data, business, or goodwill. In
addition, damages resulting from negligence on the part of the
customer including, but not limited to, the care and maintenance of
NextCentury products, or damages resulting from negligence
regarding periodic testing of the product’s performance, are not
covered under this guarantee.
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY
NEXTCENTURY MAY VOID THIS WARRANTY AND THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
THE FOREGOING WARRANTY IS THE SOLE AND EXCLUSIVE REMEDY
AVAILABLE TO THE PURCHASER AND IS IN LIEU OF ALL OTHER
WARRANTIES, GUARANTEES, OR REMEDIES, WHETHER WRITTEN OR
ORAL, EXPRESSED, OR IMPLIED, INCLUDING WITHOUT LIMITATION,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, ALL OF WHICH NEXTCENTURY HEREBY
EXPRESSLY DISCLAIMS.
8|NextCentury Submetering System
Contact Information
If there are any questions or concerns related to these guidelines,
please contact NextCentury Submetering Systems Product Support:
● Phone: (844) 538.8203 opt. 2
● Email: [email protected]

www.nextcenturymeters.com
V. 071819
RR301-TR Remote Reader
Integrated NextCentury Transceiver Version
Operation and Installation Manual
1|Product Overview
The NextCentury RR301-TR Remote Reader is an advanced meter
reading and transmitting device which provides a high visibility
remote display of up to two utility meters.
The Remote Reader has an attractive consumer design, making it an
ideal solution for apartment meter display requirements. The utility
and unit of measure are clearly displayed, ensuring an accurate
interpretation of the read.
In addition to displaying the meter read, the Remote Reader operates
as a transceiver end-point to wirelessly check-in meter reads to a
cloud-connected NextCentury Gateway. The pre-installed battery
provides up to 10 years of operation and is field-replaceable.
The Remote Reader is compatible with virtually all modern encoded
and pulse-output utility meters including water, electric, gas, run-
time, and thermal meter models.
2|Packaging Contents
A RR301 Display Unit D Sheetrock Anchors (2)
B Mounting Plate E Mounting Screws (2)
C Security Seal Assembly
3|Specifications
3.1 – Dimensions:
● Display unit and mounting plate:
145mm x 117mm x 44mm | 5.7 in x 4.6 in x 1.7 in
● Mounting holes center to center: 88.4 mm | 3.5 in (Can
be installed on a standard single gang wall-box)
3.2 – Operation Environment:
● -20°C to 60°C | -4°F to 140°F
● Water-resistant for outdoor installation (Rating
information pending)
3.3 – Battery Life:
● Up to 10 years* with default 6-hour Transceiver check-in
interval
*Note: Typical battery life assumes constant operating temperatures are
between 70°F and 90°F. Battery life may be reduced with operation outside of
this range.
3.4 - Certifications:
FCC: Pending
NTEP: Pending
IC: Pending
IP-Rating: Pending
4|Meter Compatibility
4.1 – Pulse Output Meters
● Pulse output passive (reed switch, solid-state relay,
contact relay, open-drain)
● Pulse output active (voltage pulse up to 15v)
4.2 – Encoded 3-Wire Protocol
● Neptune (Including ProRead, ECoder, ProCoder meters)
● Sensus UI-1203 (Includes many meter models from
Sensus, Hersey/Mueller, Master Meter, Badger,
Kamstrup, and Zenner)
● K-Frame (Elster/AMCO)
5|Device Setup & Configuration
In-field configuration can be conducted by a technician using their
mobile device (iOS or Android) paired with the NextCentury Direct
Connect programming device (available separately). Device pre-
programming is also available.
6|FCC Part 15 and ISED Statement
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,

www.nextcenturymeters.com
V. 071819
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
The FCC requires the user to be notified that any changes or
modifications made to this device that are not expressly approved
by Company Name may void the user’s authority to operate the
equipment.
As per 47 CFR §15.19
(All other devices shall bear the following statement in a
conspicuous location on the device:
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
As per 47 CFR §15.21
The user’s manual or instruction manual for an intentional or
unintentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the
equipment. In cases where the manual is provided only in a form
other than paper, such as on a computer disk or over the Internet,
the information required by this section may be included in the
manual in that alternative form, provided the user can reasonably
be expected to have the capability to access information in that
form.
ISED Statement
This radio transmitter (identify the device by certification number)
has been approved by Industry Canada to operate with the antenna
types listed below with the maximum permissible gain indicated.
Antenna types not included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use
with this device.
Immediately following the above notice, the manufacturer shall
provide a list of all antenna types approved for use with the
transmitter, indicating the maximum permissible antenna gain (in
dBi).
8.4 User Manual Notice for Licence-Exempt Radio Apparatus
User manuals for license-exempt radio apparatus shall contain the
following text, or an equivalent notice that shall be displayed in a
conspicuous location, either in the user manual or on the device, or
both:
This device complies with Innovation, Science and Economic
Development Canada’s licence-exempt RSSs. Operation is subject to
the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme aux flux RSS exemptés de licence
d'Innovation, Science et Développement économique Canada.
L'opération est soumise aux deux conditions suivantes:
(1) Cet appareil ne doit pas provoquer d'interférence; et
(2) Cet appareil doit accepter toute interférence, y compris les
interférences susceptibles de provoquer un fonctionnement
indésirable de l'appareil.
--------------------------
ISEDC Radiation Exposure Statement
[English] Radiation Exposure Statement: This equipment complies
with the IC RSS-102 radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator
and your body.
[French] Énoncé d'exposition aux rayonnements: Cet équipement
est conforme aux limites d'exposition aux rayonnements ioniques
RSS-102 Pour un environnement incontrôlé. Cet équipement doit
être installé et utilisé avec un Distance minimale de 20 cm entre le
radiateur et votre corps.
8|Warranty/Disclaimer
Scope of Warranty
NextCentury warrants that all communication equipment
manufactured by NextCentury will be free from defects in materials
and workmanship under normal use and in accordance with
NextCentury’s documented installation and operating procedures for
a period of three (3) years from the date of manufacture.
Products not manufactured by NextCentury, including without
limitation, accessories, attachments, or batteries used in conjunction
with NextCentury equipment are warranted, if at all, only by the
original manufacturer. NextCentury’s warranties do not include
replacement of batteries used to power NextCentury products.
Limits of Liability
This warranty only applies to Read Management System components
produced by NextCentury, and does not cover any products which
have been damaged by misconduct, negligence, vandalism, acts of
God, excessive operating conditions, or unauthorized attachments or
modifications. This warranty will be nullified and voided if products

www.nextcenturymeters.com
V. 071819
are placed in non-recommended installation application/fashion, or
are converted, altered, or treated by other than NextCentury
recommended procedures and instructions, or are read by equipment
not approved by NextCentury.
NextCentury’s liability and customer’s exclusive remedy under this
warranty is expressly limited to repair or replacement of the product
at NextCentury’s option, and is conditioned upon the customer
returning the product(s) to the location designated by NextCentury
within the warranty periods or limits stated herein and pre-paying the
freight costs both to and from specified location. In no event shall
NextCentury be liable for costs or expenses associated with the
removal or installation of products under this warranty.
NextCentury shall have no liability or responsibility to the purchaser
or any third party for any loss, cost, expense, damage, or liability,
whether direct or indirect, or for special, incidental, indirect, or
consequential damages of any kind, regardless of whether such
liability is based on breach of contract, tort, strict liability, breach of
warranties, or otherwise, and even if advised of the likelihood of such
damages. Incidental and consequential damages include, but are not
limited to, lost revenue, loss of profits, data, business, or goodwill. In
addition, damages resulting from negligence on the part of the
customer including, but not limited to, the care and maintenance of
NextCentury products, or damages resulting from negligence
regarding periodic testing of the product’s performance, are not
covered under this guarantee.
CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY
NEXTCENTURY MAY VOID THIS WARRANTY AND THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
THE FOREGOING WARRANTY IS THE SOLE AND EXCLUSIVE REMEDY
AVAILABLE TO THE PURCHASER AND IS IN LIEU OF ALL OTHER
WARRANTIES, GUARANTEES, OR REMEDIES, WHETHER WRITTEN OR
ORAL, EXPRESSED, OR IMPLIED, INCLUDING WITHOUT LIMITATION,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE, ALL OF WHICH NEXTCENTURY HEREBY
EXPRESSLY DISCLAIMS.
9|NextCentury Submetering System
Contact Information
If there are any questions or concerns related to these guidelines,
please contact NextCentury Submetering Systems Product Support:
● Phone: (844) 538.8203 opt. 2
● Email: [email protected]
Table of contents
Other Next Century Measuring Instrument manuals

Next Century
Next Century GW-301 Operating and safety instructions

Next Century
Next Century RR301 User manual

Next Century
Next Century RE4 Quick start guide

Next Century
Next Century RR4-TR Quick start guide

Next Century
Next Century BAT-301 User manual

Next Century
Next Century RR4 User manual

Next Century
Next Century RR4-TR Quick start guide