Contents
1 Safety and Warnings 4
1.1 Certicates of Conformity 4
1.2 Warranty 4
1.3 End of Life
2 Introduction and Overview 5
2.1 Introduction 5
2.2 Unpacking 5
2.3 Overview 5
2.4 Specications 7
3Cabling and Amplication 8
3.1 Amplier Layout 8
3.2 Wiring Diagram 8
3.3 LCD Screen and Menu 9
3.4 LEDs 10
3.4.1 Status LED 10
3.4.2 ETH Connector LED 10
3.5 System Conguration 11
3.6 Signal Distribution 12
3.7 Power Distribution 13
4Mechanical Congurations 14
4.1 Rigging and Suspension Safety 14
4.1.1 Fly Frame 15
4.1.2 Pull Back 18
4.1.3 Rigging From Transportation Dolly 20
4.2 Ground Stack Safety 23
4.2.1 Ground Stack on LAs518A 24
4.2.2 Dolly Ground Stack 28
4.3.1 Transportation Dolly 30
4.3.2 Transportation Dolly Storage 37
5 Accessories 39

4
1 Safety and Warnings
The lightning ash with arrowhead symbol
within an equilateral triangle is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sucient
magnitude to constitute a risk of electrical
shock.
The exclamation mark within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance instructions
• Read these instructions
• Keep these instructions
• Heed all warnings
• Follow all instructions
• Use the equipment only for its intended purpose as
instructed in this manual
• Before installing, observe the applicable safety
regulations for your country
• Always check if the equipment is installed securely
and will not fall
• Never install close to ignition or heat sources such
as radiators, ovens or any other apparatus that
produce heat.
• Do not use or install the equipment near water or
exposed to rain
• If the equipment is not functioning properly or has
been damaged in any way, switch it o immediately
• Do not open or try to service the equipment. It may
only be repaired by authorized, qualied personnel
• Clean the equipment using only a clean dry cloth
• Do not operate the unit for an extended period with
the sound distorting
• Never remove the cover, because otherwise there
may be a risk of electric shock. There are no user
serviceable parts inside. Have repairs carried out
only by qualied service personnel.
This equipment is intended for professional use.
Therefore, commercial use of this equipment is subject
to the respectively applicable national accident
prevention rules and regulations. As a manufacturer,
NEXT-proaudio is obligated to notify you formally about
the existence of potential health risks. Hearing damage
due to high volume and prolonged exposure: When in
use, this product is capable of producing high sound-
pressure levels (SPL) that can lead to irreversible hearing
damage in performers, employees, and audience
members.
For this reason, avoid prolonged exposure to volumes in
excess of 90dB.
ATTENTION! Because of the continuous evolution of
techniques and standards, NEXT-proaudio reserves the
right to change the specications of its products without
warning. For the most updated version of this manual and
general information about this and other products, please
visit our website www.nextaudiogroup.com.
1.1 Certicates of Conformity
Certicates of conformity can be found at:
https://www.nextaudiogroup.com/en/apoio-ao-
cliente/downloads
1.2 Warranty
Warranty details can be found at:
www.nextaudiogroup.com/en/apoio-ao-cliente/warranty
1.3 End of Life
When to be denitively put out of
operation, take the product to a local
recycling plant for a disposal which is not
harmful to the environment.
Devices marked with this symbol must
not be disposed of as household waste.
Contact your retailer or local authorities
for more information.

5
2 Introduction and Overview
Thank you for purchasing a NEXT LA210x line array element. This manual will
provide you with useful and important information about your NEXT LA210x. Please
devote some time reading this manual and keep it at hand for future reference.
NEXT-proaudio is concerned with your safety and well-being so please follow all
instructions and heed all warnings. A better understanding of specic features of
the LA210x line array will help you to operate your system to its full potential. With
a continuous evolution of techniques and standards NEXT-proaudio reserves the
right to change the specications of its products without warning. For the latest
information please visit: www.nextaudiogroup.com.
2.1 Introduction
2.2 Unpacking
Each NEXT LA210x line array element is built in Europe (Portugal) by NEXT-proaudio,
according to the highest standards and thoroughly inspected before it leaves the
factory. When unpacking your LA210x please examine it carefully for any signs of
transit damage and inform your dealer immediately if any is found.
NEXT-proaudio recommends that you retain the original packaging so that the
system can be repackaged in future if necessary. Please note that NEXT-proaudio
and its authorized distributors cannot accept any responsibility for damage to
any returned product using non-approved packaging.
2.3 Overview
The LA210x is a medium format three-way, coaxial, active line array element
designed to support a wide range of mid to large-sized touring applications and
installations where ease of use, from transportation to installation and rigging,
are critical. Built-in powerful DSP and amplication eliminates amplier racks, long
loudspeaker cables, and basic system calibration.
Custom made European transducers and a maximally optimized acoustic design
provide excellent sound delity at very high SPL levels. The LA210x features dual
10-inch (3-inch voice coil) neodymium woofers and a groundbreaking coaxial ring
radiator loaded by an exclusively developed OSWG waveguide. This acoustic
design delivers exceptional phase coherence and consistent coverage down to
300Hz and the most accurate transient reproduction.

6
Onboard, advanced, powerful 96kHz/40bit SHARC DSP engine, monitored by
built-in LCD screen with a preset loading encoder, can be remotely monitored and
controlled through ethernet by a PC. The full-featured PC-software automatically
identies each device and allows simultaneous control of multiple devices through
grouping facility. Everything you need to ne-tune the sound of your system is right
there.
The system is driven by an internal fan cooled 2000W 3-way ultra-ecient Class-D
amplier module releasing 1550W for LF section, 275W for MF section and 175W
for the HF section. Integrated universal mains power supply with PFC provides
consistency and optimum performance anywhere in the world.
The 3-point rigging system allows for quick and easy system setup. The LA210X
elements are easily connected via two front links. A rear centre link allows the user
to dene relative splay angles from 0° to 10°. The system will automatically lock to
the predened angles when lifting the array.
2 Introduction and Overview

7
2.4 Specications
Frequency Response (-6dB) 58 Hz - 19000 Hz
Low Frequency Extension
(-10dB) 54 Hz
Nominal Coverage (-6dB) 100° (300 Hz - 16 kHz) x 10°
RMS Power 2000 W (LF: 1550 W | MF: 275 W | HF: 175 W)
Amplier Technology 3-Channel UMAC Class D - Full Bandwidth PWM Modulator With Ultra-Low
Distortion
DSP Technology 96 kHz / 40 bit SHARC DSP
Latency 1.5 ms
DSP Adjustable Parameters Filters: PEQ, FIR, hi/lo-shelving, all-pass, band-pass, hi/lo-pass | Limiters: RMS
Voltage, Peak Voltage | Groups: Mute, Delay, Level, Polarity, EQ
DSP Presets 24
Delay Adjustment 500ms (172m) on Input + 400ms (138m) on Groups
Control Type Control via LCD and Encoder on the Back Panel | Control via Software using
Ethernet - Max. Cable Length 70m
Maximum SPL (calculated) RMS: 136dB | Peak: 142dB (Full-Space)
Low Frequency Driver 2 x 10” / 3” VC, Neodymium, B&C Custom Speaker
High Frequency Driver 1 x 1.4” Neodymium Coaxial Ring Radiator Driver (MF: 3” VC | HF: 2” VC)
Audio Signal Inputs/Outputs Analogue | AES (AESOP)
Input/Output Connectors 1 x XLR | 1 x Neutrik EtherCON®
Protections Clip Limiter | Temperature | Over Current | DC Protection | HF Protection
Operating Temperature Range 0° C - 40° C
Cooling Type External Aluminium Heat Sink with Internal Speed Controlled Fan
Power Supply UREC Universal Mains Switch Mode Power Supply (SMPS) with Power Factor
Correction (PFC) and Standby Converter
Power Input AC 100V - 240V 50Hz/60Hz
Mains Connector Dual (IN/OUT) Neutrik powerCON TRUE1 TOP®
Power Consumption 275W
Recommended Subwoofer LAs518A
Special Features Speaker Cabinet Auto-Identication via Software
Fittings 3-Point Adjustable Rigging System (0° to 10° with 1° Step)
Handles 1 on Each Side, 2 on the Back
Grille Black Perforated Steel
Construction 15mm Multi-Laminate Birch Plywood
Finish Semi-Matte Black Textured Coating
Dimensions (WxHxD) 720 x 350 x 550 mm (28.3” x 13.8” x 21.7”)
Net Weight 37 kg (81.6lb)
Shipping Weight 40 kg (88.2lb)
2 Introduction and Overview

8
3 Cabling and Amplication
3.1 Amplier Layout
2
3
4
5
6
8
9
1. Encoder
2. LCD Screen
3. Analogue Out (XLR)
4. Analogue In (XLR)
5. ETH/AESOP In (Neutrik® etherCON)
6. ETH/AESOP Out (Neutrik® etherCON)
7. Status LED
8. Power In
(Neutrik® PowerCON TRUE1 TOP)
9. Power Out
(Neutrik® PowerCON TRUE1 TOP)
+
-
+
-
+
-
+
-
Power
Supply
Power In
Signal In
Power
Supply
3.2 Wiring Diagram
1
7

9
3.3 LCD Screen and Menu
3 Cabling and Amplication
At start up the load screen will display for about four seconds.
NEXT pdroau oi
-
After that the main menu screen will display:
1 : XLA210 SA
8-6* -
YARRA
1
23
1. Displays the current active preset.
2. Displays the name of the device.
3. Displays the amplier state. The letters displayed have the following meaning:
O: System is running normally S: Amp is starting up
E: Error on AMP connection state C: PC is connected
-: No connection Input state A: Analogue input
L: AES-input locked U: AES-input unlocked
To access the settings menu push the encoder. Rotate the encoder and push
again to select the required setting. Select the setting using the encoder, to
return to the main menu simply wait for four seconds. The settings menu is as
follows:
0. Main Menu 5. Set Subnet
1. Volume 6. Select input
2. Delay 7. System temp
3. Load Preset 8. Info
4. Set IP 9. Amp state
All of this information can be accessed and changed via the X-NET control
software. For more information and guidance on its use go to the download
section of the LA210x product page:
https://www.nextaudiogroup.com/en/product/la210x/

10
3 Cabling and Amplication
3.4 LEDs
3.4.1 Status LED
3.4.1 ETH/AES Connector LED
1
2
The ETH/AES connectors have two LED
indicators above them as shown in the diagram.
1. A standard Ethernet indicator and ashes
green when the connection is active.
2. This LED indicates the AESOP connection. If
the LED is inactive then AESOP is not selected.
If ashing yellow then AESOP is selected but
not locked. A solid yellow light indicates the
AESOP is selected and locked.
The status LED, see section 3.1, has the following meaning:
• Solid Green: analogue signal present
• Red Blinking: analogue input clip
• Solid Red: AES locked

11
IMPORTANT INFORMATION
Ethernet cables MUST be connected using the correct IN/OUT
connectors as shown in section 3.1. Failure to use the correct
connection will result in malfunction.
3.5 System Conguration
3 Cabling and Amplication
Note: Here the audio link between cabinets is shown using ethernet cable
for clarity. It is possible to add an XLR link between each cabinet as a
redundancy. If for any reason the network link fails the analogue link with
the XLR cable will automatically activate.
Below is an example of a conguration of the LA210x systems with LAs518A
subwoofers. For other examples of signal connection see section 3.4.

12
3 Cabling and Amplication
3.6 Signal Distribution
Analogue
In
Control
In
Analogue
Out
AESOP
(AES + Control)
AESOP Out
(AES + Control)
A redundancy can be added by linking the cabinets with XLR cable.
Control
In
Analogue
In
AESOP
(AES + Control)
AESOP Out
(AES + Control)
AES In
(XLR)
Control
In (ETH)
AESOP
Converter
AESOP
(AES + Control) AESOP Out
(AES + Control)
AESOP
(AES + Control)
In this rst example the analogue cable is only supplied to the rst unit and from
there is distributed by AESOP using the ethernet cable.
It is also possible to connect AES directly (XLR cable) from a mixer, using the NEXT
AESOP Converter. The AESOP Converter will mix both AES and control signals into
one single AESOP ethernet cable.

13
Maximum Ethernet cable distance between devices is 70m. NEXT-proaudio
advises using CAT6 S/FTP cable
3.7 Power Distribution
When linking units for power distribution the following is the maximum units that
can be linked:
Voltage LA210x LAs518A
230 V Max 6 units Max 2 units
110 V Max 4 units Max 1 unit
3 Cabling and Amplication
AES In
(XLR)
Control
In (ETH)
AESOP
Converter
AESOP
(AES + Control) AESOP Out
(AES + Control)
Analogue
In
Analogue
Out
AESOP
(AES + Control)
In this example if the AESOP signal is interrupted for any reason, the DSP will
switch to the analogue signal instantly (fallback option must be enabled on X-NET
software). This method is highly recommended when redundancy is needed.

14
4 Mechanical Congurations
4.1 Rigging and Suspension Safety
• Before rigging or suspending NEXT LA210x systems, inspect all components
and all hardware for any signs of damage or missing parts.
• If you nd any damaged, corroded or deformed parts, do not use them,
replace them immediately.
• Do not use hardware that isn’t load rated or that its rating is not enough to
handle the system’s weight with a good safety factor (5 minimum). Don’t forget
that the hardware won’t just hold the systems weight. It must be sturdy enough
to handle dynamic forces, like winds for example, without any part deformation.
NEXT-proaudio advises customers to contact a licensed, professional engineer
regarding equipment installation.
• NEXT LA210x system installation should only be carried out by qualied personnel.
• Always use adequate protective clothing and equipment to prevent
possible injuries.
• Only install the systems on solid, levelled ground and isolate the surrounding
area during installation and operation, to prevent general public presence
near the systems.
• Be sure to understand and follow all local and national regulations regarding
equipment installation.
• Failure to comply with these instructions may result on injury or death.

15
Step 1:
Remove all rigging pins from the y
frame.
Step 2:
Lower the y frame into position
aligning the front holes of the y
frame with the rigging elements on
the LA210x.
4.1.1 Fly Frame
Step 3:
Insert both pins at the front of the
y frame.
Step 4:
Remove both pins from the rear
rigging assembly to allow to rear
link to swing free.
4 Mechanical Congurations

16
Step 5:
Rotate the rear link into position
and x it into place with the rear
pin on the y frame.
Step 6:
With the rigging in place it is now
possible to raise the assembly from
the shackle.
Step 7:
Remove the rigging pins from the
lower end of the rigging assembly.
Step 8:
Move the next cabinet into position
and x it at the front of the rigging
assembly with the rigging pins.
4 Mechanical Congurations

17
Step 9:
Remove both pins from the rear
rigging assembly on both cabinets
to release the rear link.
Step 10:
Rotate the rear link into position
and insert the pins on the right
hand side.
Note: The hole numbers
determine the splay
angle of the assembly.
To determine what angle
the cabinets should be
congured use EASE Focus.
Step 11:
Insert the left hand pin in the same hole
number as the right hand side to lock
the cabinet in position.
Repeat steps 7 to 11 for additional
cabinets as required.
4 Mechanical Congurations

18
4.1.2 Pull Back
Step 1:
Remove both pins from the bottom
cabinet once the array has been
assembled.
Step 2:
Move the pull back accessory into
position aligned with holes marked
pull back (number 5 on the left hand
side and number 9 on the right hand
side) and x into position using the
pins on the rigging assembly.
4 Mechanical Congurations

19
Step 3:
Fix the hoist to the shackle on pull back
assembly and raise into position.
4 Mechanical Congurations

20
4.1.3 Rigging From Transportation Dolly
Step 1:
Remove the pins for the front and
rear of the lid of the dolly assembly.
Step 2:
Lower the y frame assembly into
position and attach with the pins
as shown.
4 Mechanical Congurations
This manual suits for next models
1
Table of contents
Other Next PROAUDIO Speakers manuals

Next PROAUDIO
Next PROAUDIO PFA15 User manual

Next PROAUDIO
Next PROAUDIO X8 User manual

Next PROAUDIO
Next PROAUDIO PFA12 User manual

Next PROAUDIO
Next PROAUDIO LA26 User manual

Next PROAUDIO
Next PROAUDIO HFA112 User manual

Next PROAUDIO
Next PROAUDIO HFA108 User manual

Next PROAUDIO
Next PROAUDIO HFA110 User manual

Next PROAUDIO
Next PROAUDIO HFA212 User manual

Next PROAUDIO
Next PROAUDIO I Series User manual