NI SA-413T Purpose and Introduction
Note Before you begin, install your NI PXIe-4138/4139 source measure
unit.
This document explains how to install the NI SA-413T (NI 413T). The NI 413T is a
system SMU triaxial adapter designed to enable triaxial cable connectivity for the
NI PXIe-4138/4139.
To access NI 413T documentation, navigate to Start > All Programs > National
Instruments > NI-DCPower > Documentation.
Caution You can impair the protection provided by the NI 413T if you use
it in a manner not described in this document.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits
for electromagnetic compatibility (EMC) stated in the product specifications. These
requirements and limits provide reasonable protection against harmful interference
when the product is operated in the intended operational electromagnetic
environment.
This product is intended for use in industrial locations. However, harmful
interference may occur in some installations, when the product is connected to
a peripheral device or test object, or if the product is used in residential or
commercial areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in strict
accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved
by National Instruments could void your authority to operate it under your local
regulatory rules.
© National Instruments 3
Triaxial Adapter for NI System SMUs Specifications

Installing the NI 413T
Caution The NI 413T is not rated for use >60 VDC or >42 Vrms with respect
to earth ground. When using the NI 413T with an NI PXIe-4138/4139, do not
float an output >60 VDC or >42 Vrms with respect to earth ground.
1. Install your NI 4138/4139 device in your chassis. Refer to the
NI PXIe-4138/4139 Getting Started Guide for installation instructions.
2. Ensure the AC power source is connected to the chassis before installing the
adapter.
The AC power cord grounds the chassis and protects it from electrical
damage.
3. Power o the chassis.
4. Touch any metal part of the chassis to discharge static electricity.
5. Slide the accessory into the output connector on the front panel of
the NI 4138/4139 until it is fully inserted.
Figure 1. Accessory Installation
6. Using a Phillips screwdriver, tighten the mounting screws to secure the
accessory to the NI 4138/4139 front panel.
7. Attach triaxial cables to the triaxial cable connectors on the accessory.
ni.com
4
Triaxial Adapter for NI System SMUs Specifications

8. Power on the chassis.
Specifications
Maximum Voltage and Current Limit Characteristics
Voltage between any two terminals 60 VDC
Voltage to earth ground 60 VDC
HI/LO current 3 A
Caution Applying levels beyond the ratings specified in this section can
result in permanent damage to the device.
Caution Connect only voltages that are within these limits.
Physical Characteristics
Dimensions 7.4 cm × 8.9 cm × 1.9 cm (2.90 in. × 3.50 in. × 0.75 in.)
Weight 119 g (4.2 oz)
Connectors Triaxial (MIL-STD-348A) and 5.08 mm (2 position)
© National Instruments 5
Triaxial Adapter for NI System SMUs Specifications

NI 413T Front Panel
Figure 1. NI 413T Front Panel
3
4
6
5
1
2
Item Description
1 Output connector, terminal 0 Output LO
2 Output connector, terminal 1 Sense LO
3 Triaxial connector pin Output HI
4 Triaxial connector inner shield Guard
5 Triaxial connector pin Sense HI
6 Triaxial connector outer shield Chassis ground
NI 413T Back Panel
Figure 1. NI 413T Back Panel
1
ni.com
6
Triaxial Adapter for NI System SMUs Specifications

Item Description
1 Connector Connects to output connector of NI 4138/4139
Cleaning Statement
Caution Clean the hardware with a so, nonmetallic brush. Make sure
that the hardware is completely dry and free from contaminants before
returning it to service.
Environment
Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature)
Pollution Degree 2
Indoor use only.
Operating Environment
Ambient temperature
range
0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and
MIL-PRF-28800F Class 2 high temperature limit.)
Relative humidity range 10% to 90%, noncondensing (Tested in accordance with
IEC 60068-2-56.)
Storage Environment
Ambient temperature
range
-40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.)
© National Instruments 7
Triaxial Adapter for NI System SMUs Specifications

Relative humidity range 5% to 95%, noncondensing (Tested in accordance with
IEC 60068-2-56.)
Shock and Vibration
Operating shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with
IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.)
Random vibration
Operating 5 Hz to 500 Hz, 0.3 grms
Nonoperating 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating
test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)
Compliance and Certifications
Safety
This product is designed to meet the requirements of the following electrical
equipment safety standards for measurement, control, and laboratory use:
■IEC 61010-1, EN 61010-1
■UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or
the Online Product Certification section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical
equipment for measurement, control, and laboratory use:
■EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
■EN 55011 (CISPR 11): Group 1, Class A emissions
ni.com
8
Triaxial Adapter for NI System SMUs Specifications

■EN 55022 (CISPR 22): Class A emissions
■EN 55024 (CISPR 24): Immunity
■AS/NZS CISPR 11: Group 1, Class A emissions
■AS/NZS CISPR 22: Class A emissions
■FCC 47 CFR Part 15B: Class A emissions
■ICES-001: Class A emissions
Note In the United States (per FCC 47 CFR), Class A equipment is intended
for use in commercial, light-industrial, and heavy-industrial locations.
In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A
equipment is intended for use only in heavy-industrial locations.
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or
medical equipment that does not intentionally generate radio frequency
energy for the treatment of material or inspection/analysis purposes.
Note For EMC declarations, certifications, and additional information,
refer to the Online Product Certification section.
CE Compliance
This product meets the essential requirements of applicable European Directives, as
follows:
■2014/35/EU; Low-Voltage Directive (safety)
■2014/30/EU; Electromagnetic Compatibility Directive (EMC)
Online Product Certification
Refer to the product Declaration of Conformity (DoC) for additional regulatory
compliance information. To obtain product certifications and the DoC for this
product, visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
© National Instruments 9
Triaxial Adapter for NI System SMUs Specifications

Environmental Management
NI is committed to designing and manufacturing products in an environmentally
responsible manner. NI recognizes that eliminating certain hazardous substances
from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our
Environmental Impact web page at ni.com/environment. This page contains the
environmental regulations and directives with which NI complies, as well as other
environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all NI products
must be disposed of according to local laws and regulations. For more
information about how to recycle NI products in your region, visit ni.com/
environment/weee.
电子信息产品污染控制管理办法(中国 RoHS)
中国客户 National Instruments 符合中国电子信息产品中限制使用某
些有害物质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信
息,请登录 ni.com/environment/rohs_china。(For information about
China RoHS compliance, go to ni.com/environment/rohs_china.)
Worldwide Support and Services
The NI website is your complete resource for technical support. At ni.com/support,
you have access to everything from troubleshooting and application development
self-help resources to email and phone assistance from NI Application Engineers.
ni.com
10
Triaxial Adapter for NI System SMUs Specifications

Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty,
and other services.
Visit ni.com/register to register your NI product. Product registration facilitates
technical support and ensures that you receive important information updates from
NI.
A Declaration of Conformity (DoC) is our claim of compliance with the Council
of the European Communities using the manufacturer’s declaration of conformity.
This system aords the user protection for electromagnetic compatibility (EMC)
and product safety. You can obtain the DoC for your product by visiting ni.com/
certification. If your product supports calibration, you can obtain the calibration
certificate for your product at ni.com/calibration.
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin,
Texas, 78759-3504. NI also has oices located around the world. For telephone
support in the United States, create your service request at ni.com/support or
dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States,
visit the Worldwide Oices section of ni.com/niglobal to access the branch oice
websites, which provide up-to-date contact information, support phone numbers,
email addresses, and current events.
© National Instruments 11
Triaxial Adapter for NI System SMUs Specifications
© 2022 National Instruments Corporation.
Table of contents
Other NI Adapter manuals
Popular Adapter manuals by other brands

Corinex
Corinex Wireless G USB Mini Adapter manual

Linksys
Linksys WGA600N - Wireless-N Gaming Adapter Bridge Quick installation guide

Digitus
Digitus DA-70831 user manual

StarTech.com
StarTech.com DUAL-M2-PCIE-CARD-B quick start guide

Telegesis
Telegesis ETRX2USB product manual

TP-Link
TP-Link Kasa Smart KP405 user guide