Noark EX9N-DH-5KT-AU User manual

07/08/2021 11:11:10 Thu
76%
2.00
KW
-1.39
KW
0.00
KW
KW
0 7
0 5
0 5
0 5
ON
Signal
on
2.00

ContentsContents
1. Safety Introductions
2. Product instructions
2.1 Product Overview
…………………………………………………
…………………………………………………
2.2 Product Size
01
02-04
2.3 Product Features
2.4 Basic System Architecture
2.5 Maintenance of the System
……………………………………………………………
3. Installation
3.1 Parts list
3.2 Mounting instructions
3.3 Battery connection
3.5 PV Connection
3.4 Grid connection and backup load connection
05-23
3.6 CT Connection
3.7 Earth Connection(mandatory)
3.8 WIFI Connection
3.10 Wiring System for Inverter
3.9 Communication Connection
3.12 Typical application diagram of diesel generator
3.11 Wiring diagram
……………………………………………………………………
6. Mode 38-39
5.6 Battery Setup Menu
5.7 System Work Mode Setup Menu
5.8 Grid Setup Menu
5.9 Generator Port Use Setup Menu
5.10 Advanced Function Setup Menu
5.11 Device Info Setup Menu
……………………………………………………………
……………………………………………………
4. OPERATION
4.1 Power ON/OFF
4.2 Operation and Display Panel
5. LCD Display Icons
5.1 Main Screen
5.2 Solar Power Curve
24
25-38
5.4 System Setup Menu
5.5 Basic Setup Menu
5.3 Curve Page-Solar & Load & Grid
………………………………………………
………………………………………………………………
7. Limitation of Liability
8. Datasheet
39-43
44-47
……………………………………
9. Package and transport inverter 47
……………………………………………
10. Disposing of the inverter 47
……………………………………………………………
11. Appendix I 48-49
……………………………………………………………
12. Appendix II 50
3.6.1 Meter Connection
3.13 phase parallel connection diagram

- 01 -

- 02 -
12
1
2
3
4
5
8
9
13
17
16
7
6
10
11
14
15

- 03 -
2.2 Product Size
254.0 mm
279.0 mm
240.00 mm
120.00 mm
279.0 mm
450.9 mm
422.0 mm
782.5 mm
658.0 mm
422.0 mm
363.00 mm

- 04 -
GridBackup Load
WiFI
GPRS
phoneCloud services
On-Grid Home Load
Generator
ATS
Grid-connected InverterSmart Load
Battery
Solar
CT
AC cable DC cable

- 05 -
Three-Phase Smart Meter
SET ESC

- 06 -
· ℃

≥500mm
≥500mm
- 07 -

- 08 -
Model
Wire Size
Cable(mm )
2
Torque value(max)

- 09 -
29.54mm
15.3/16mm
10.5mm
30mm
30mm

- 10 -
Batt Temp
Sensor
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
CT -L1
CT -L2
CT -L3
Gen start-up
N/O Relay
CN1: TEMP: 1,2
CT_1: 3,4
CT_2: 5,6
CT_3: 7,8
GS (diesel generator startup signal)
relay
coil
open
contact
G S
CN2: G_start: 1,2
G_valve: 3,4
Grid_Ry: 5,6
RSD: 7+, 8-
CN1 CN2
Inverter
Parallel_A Parallel_B Meter-485
Modbus BMS
DRM

Temp. CT
- 11 -
12
Inverter

- 12 -
.
.
Model
Wire Size
Cable(mm )
2
6
Torque value(max)
Model
Wire Size
Cable(mm )
2
6
Torque value(max)
GRID LOAD GEN PORT
GRID
T(L3)
PE
S(L2)
R(L1)
N
T(L3)
PE
S(L2)
R(L1)
N
T(L3)
S(L2)
R(L1)
GEN PORT
LOAD
N
N
RST

- 13 -
Model
Wire Size
Cable(mm )
2
4

- 14 -
Inverter Model Ex9N-DH
-10KT-AU
Ex9N-DH
-8KT-AU
Ex9N-DH
-6KT-AU
Ex9N-DH
-5KT-AU
Ex9N-DH
-12KT-AU
2
2+1
1+11+1 1+1 2+1
Safety Hint:
Safety Hint:
Note:
Safety Hint:

- 15 -
Safety Hint:
Cable type Range Recommended value
Cross secon(mm )
.
7mm
7mm

- 16 -
Warning:

- 17 -
White wire 543 6 7 8
Black wire
Grid
N
R
S
T
CT1
CT2
CT3
CT
Arrow pointing
to inverter
*Note:
Inverter
GRID
N
RST
Ground

- 18 -
R
S
T
N
PE
Parallel_A Parallel_B Meter-485 port
RS485A
RS485B
Three-Phase Smart Meter
SET ESC
1 74 10
2524
3
96 10
Three-Phase Smart Meter
SET ESC
1 74 10
2524
3 96 10
RS 485
CHNT DTSU666
(3,6,9,10)
(1,4,7,10)
R
S
T
Grid
Inverter
R
R
S
S
T
T
N
N
Parallel_A Parallel_B Meter-485 port
RS485A
RS485B
Grid
Eastron meterEastron SDM630-Modbus V2
RS 485
RS 485 B RS 485 A
B A G
(5,6,7,8)
(1,2,3,4)
1234
R
S
T
5678
GND
Eastron
5 6 7 8
R
S
T
Eastron
5 6 7 8
Inverter
PE
GND
GRID
N
RST
Ground
GRID
N
RST
Ground
Note:
Note:
This manual suits for next models
4
Table of contents