18
Error
Code
303
313
323
333
613
633
643
703
713
723
733
760
763
How to Fix Problem and Reset applianceContent of Error Method of detecting Error Diagnosis point (Trouble Point)No.
DC 0.7- 4.4 V2
5
CN63
32 - 212 °F
0 - 100 °C
32 - 212 °F
0 - 100 °C
32 - 212 °F
0 - 100 °C
2CN63
Confirm the air inlet thermistor detection temperature
by Maintenance Monitor (No.38).
Compare to temperature characteristic list on pg.16.
Check for open or short circuit or for an improper connection.
Confirm the water return thermistor detection
temperature by Maintenance Monitor (No.34).
Compare to temperature characteristic list on pg.16.
Check for open or short circuit or for an improper
connection.
Confirm the heat exchanger thermistor detection
temperature by Maintenance Monitor (No.37).
Compare to temperature characteristic list on pg.16.
Check for open or short circuit or for an improper
connection.
Confirm the water supply thermistor detection
temperature by Maintenance Monitor (No.35).
Compare to temperature characteristic list on pg. 16.
Check for open or short circuit or for an improper
connection.
Confirm the measured fan speed by Maintenance Monitor
(No.12).
If the fan motor does not rotate, but voltage is
normal, then the fan motor should be replaced.
If the voltage is abnormal, replace the circuit board.
If the fan motor is rotating and if the voltage is normal,
but there is a "613" error code, then the fan motor should
be replaced.
If the voltage is normal, but circulator is not running,
replace the circulator.
If the voltage is abnormal, replace the circuit board SC.
Measure the resistance through the air
inlet thermistor.
Check for improper connection of the
air inlet thermistor.
1
Measure the resistance through the
water supply thermistor.
Check for improper connection of the
water supply thermistor.
Measure the resistance through the
heat exchanger thermistor.
Check for improper connection of the
heat exchanger thermistor.
Measure the resistance through the water
supply thermistor.
Check for improper connection of the water
supply thermistor.
Check that the fan is rotating and check
the pulse frequency from the fan rotational
frequency sensor.
Check for improper connection of the fan.
Check voltage from circuit board.
Check the Priority1 circulator is running.
Check for improper connection of the circulator.
Check connection from circuit board SC to
Junction box.
Check whether the Priority1 circulator fuse
on the Junction Box is open.
Check for improper connection of the water
flow switch.
Check for blocking of the water flow switch.
1
1
1
1
1
3
2
1
Detection of open/short abnormality
of air inlet thermistor.
Detection of open/short abnormality
of heat exchanger thermistor.
Detection of fan speed abnormality.
Heat exchanger thermistor
abnormality
Fan motor abnormality
Air inlet thermistor abnormality
Detection of open/short abnormality
of water return thermistor.
Water return thermistor
abnormality
Detection of open/short abnormality
of water supply thermistor.
Water supply thermistor
abnormality
If the voltage is normal, but circulator is not running,
replace the circulator.
If the voltage is abnormal, replace the circuit board SC.
If Priority2 circulator fuse has blown, remove the cause
of excess current, and then replace the 6A fuse.
Check the Priority2 circulator is running.
Check for improper connection of the circulator.
Check connection from circuit board SC to
Junction box.
2
3
Check whether the Priority2 circulator fuse
on the Junction Box is open.
Circuit board abnormality.
Check connection from operation panel
(remote controller) to circuit board.
Check the operation panel (remote controller)
and circuit board for damage.
Detection of circuit board
abnormality.
Circuit board abnormality
1
Gas valve drive circuit abnormality.Detection of circuit board
abnormality.
Gas valve drive circuit abnormality
Detection of operation panel
(remote controller) transmission
abnormality.
Operation panel (remote controller)
transmission abnormality.
When the "water flow switch"
did not turn ON even if the
Priority2 circulator was turned on.
When the "water flow switch"
did not turn ON even if the
Priority1 circulator was turned on.
Priority1 circulator abnormality
Priority2 circulator abnormality
Disconnect the electrical power, then reconnect
electrical power to the boiler to reset the system.
If the circuit board abnormality is continuous, replace
the circuit board.
Disconnect the electrical power, then reconnect
electrical power to the boiler to reset the system.
If the error code "713" is continuous, replace the
circuit board.
1
1
1
Detection of circuit board SC
transmission abnormality.
Circuit board SC transmission
abnormality
1
2
Measure the current from the flame
when there is no flame.
Check for "Control switch connector"
is disconnected or connected while
the boiler has power.
Check for proper setting (Dip switch).
Detection of flame when no
flame is present.
Detection of circuit board
setting abnormality.
Circuit board setting abnormality
(High elevation connector,
Dip switch, etc.)
Flame rod circuit abnormality
(Detection of flame when no
flame is present)
If the "723" error code is displayed, check the signal
from the flame rod (also make sure that there is not a
problem with the grounding of the appliance).
If the signal is normal, replace the circuit board.
If it is abnormal, replace the flame rod.
Check the Dip switch setting.
If a setting is incorrect, correct the Dip switch setting.
This error code is displayed when the "Control switch
connector" is disconnected or connected while the
boiler has power. Disconnect power to the boiler
before making this adjustment.
Control switch connectors:
*High Elevation Disconnect
(Fan Speed Corrector)
*Air Flow Connector (Air Flow Switch)
*Emergency operations only
(Emergency Operations Switch)
CN & Pin No.Part
Flow chart
No.
CN63
CN63
CN75
CN78
CN89A
CN89
CN89A
CN89
1
1
2
3
BL - BL
BL - BL
7
Air inlet thermistor
Water return
thermistor
20
Flame rod
5
8
9
2
7
7
19
6
1
1
5
33
wire color Normal value
W - W
DC 1- 4.5 V
DC 1- 4.5 V
2CN63
CN63
Water supply
thermistor
Fan motor
Priority1
circulator fuse
Priority1
circulator fuse
Water flow switch
Priority2 circulator fuse
Priority2 circulator
Water flow switch
41W- W
DC 1- 4.5 V2CN63
CN63
CN27
Te r minal
B
Te r minal
B
CN75
CN75 CN75
Te r minal
B
Te r minal
B
Heat exchanger
thermistor 4
4
1
3
W - W
BR - BL
R - BL
BK - W
BK - BK
BK - W
BK - BK
CN27
Y - BL
Junction box
Junction box
W - W
CN &
Pin No. Remarks
BL - Burnercase
BL - Burnercase
If Priority1 circulator fuse has blown, remove the cause
of excess current, and then replace the 6A fuse.
Confirm "Water flow switch ON / OFF" by Maintenance
Monitor (No.65).
If the circulator is running, but water flow switch is OFF,
check the flowrate and adjust if necessary.
Remove it if the water flow switch is blocked.
Check for improper connection of the water
flow switch.
Check for blocking of the water flow switch.
Confirm "Water flow switch ON / OFF" by Maintenance
Monitor (No.65).
If the circulator is running, but water flow switch is OFF,
check the flow rate and adjust if necessary.
Remove it if the water flow switch is blocked.
10 kHz - 100 kHz
DC 0.45µA or less
If there is a voltage abnormality, replace the circuit board.
If a voltage is normal, replace the operation panel
(remote controller).
Check connection from circuit board SC to
circuit board.
Check the circuit board SC and circuit board
for damage.
If there is a voltage abnormality, replace the
circuit board.
If a voltage is normal, replace the circuit board SC.
2
2
2
1
5
3
2
7
4
DC 7 - 45 V
DC 10 - 14 V
AC 108 - 132 V
Closed circuit
Closed circuit
DC 8 - 11 V When switch is OFF.
When Priority1 calls
for heat.
AC 108 - 132 V When Priority2 calls
for heat.
When switch is ON.DC 1 V or less
100 Hz - 400 Hz
DC 8 - 11 V When switch is OFF.
When switch is ON.DC 1 V or less
DC 13 - 16 V
DC 13 - 16 V
CN89C
CN89
CN89C
CN89
3
1
1
3
BL - BL
BL - BL
DC 13 - 16 V
DC 13 - 16 V