7
WARRANTY
TERMS AND
CONDITIONS
The manufacturer, distributor and all the parties
involved in the sale do not assume any liability
for losses and economic damage from any
malfunction of the product. In accordance with
current regulations the manufacturer, distributor
and all the parties involved in the sale are not
responding in any case for damages, including
direct, indirect ones, loss of net income, loss of
savings and additional damage and other details
consequences going beyond the damage caused
by the breach of warranty, contract, strict liability,
wrongdoing or due to other causes, resulting
from the use or inability to use the product and/
or paper and electronic documents, including
the lack of service.
For further information on the help service visit
the website www.nuvitababy.com
This product benets of a warranty of 24 months on
material and manufacturing defects, starting from
the date of purchase (see sales slip).
The warranty of 24 months does not include
damages caused by the usual use of parties
identied as“consumable” (e.g. batteries, brush
heads or parts subject to usury).
The legal guarantee of 24 months is void if:
The product has undergone aesthetic damage
due to improper use not in accordance with
instructions in the manual.
This product has been modied and / or
tampered with.
The cause of the failure was due to poor
maintenance of the individual components and
/ or accessories and / or supplies (e.g. oxidation
and / or scaling due to the retention of water or
other liquids, sediment blocking the sensor, leak
of corrosive liquid from batteries.)
The following is excluded from the legal guarantee
of 24 months:
Costs related to replacements and / or repair
of parts subject to wear or costs for ordinary
maintenance of the product.
The costs and risks involved in transporting
the product to and from the store where you
purchased or otherwise authorized collection
centre to receive the products under warranty.
Damage caused by or resulting from improper
installation or improper use not in accordance
with the directions in the instruction manual.
Damage due to natural disasters, accidental
events or adverse conditions not compatible
with the product.
Defects that have a negligible eect on
product performance.
OPERATING INSTRUCTIONS
NOTE:When carrying a lled water tank, place one hand under for support.
Once the water tank is in place, do not attempt to move the humidier. If it has to be moved,
unplug the unit and drain water from the base before moving.
Once the unit is plugged in or during operation, do not attempt to pick up the water tank.
Pay attention to the water level - add water when low.
NOTE:
Lift and remove mist nozzle.
Remove water tank by grasping rmly and lift up.
Turn water tank over and turn the cap counter-clockwise to open. Fill with COOL tap water or
DISTILLED water. DO NOT USE HOT WATER. Do not add fragrance or oil in the water – it will cause
malfunction of the unit!
Replace the ll cap by turning clockwise – do not over tighten.
Place water tank back in place, making sure the tank is correctly aligned with the body; then replace the
mist nozzle.
Plug in power source.
Turn the Power/Mist Intensity knob clockwise to turn on. You will hear a “click”.
To adjust mist intensity, turn the Power/Mist Intensity knob accordingly. Clockwise increases mist
intensity and counter-clockwise decreases.
STORAGE
Save the box for o-season storage.
Clean the tank, base and all parts thoroughly and dry completely before storage.
If water is left in the unit during storage, it may harden and leave deposits that may aect the unit
from operating properly.
Leave the cap of the water tank loose. This will prevent the cap and gasket from sticking together
and prolong the life of the gasket.
Rinse the silver ion stick under clear running water and store back in place
The ceramic lter normally lasts for 2 years, store it in a cool dry place.
CARE AND MAINTENANCE
Turn o power and unplug unit before cleaning.
Never use a detergent or any cleaning chemicals to clean the tank or base. Detergent dissolved
in the water supply can interfere with the mist output.
If water tank is extremely dirty, soak with mild bleach and water solution and rinse clean. Never
use detergent.
Wipe the exterior of the body with a damp cloth.
Do not spray water or any liquid onto the control.
Never immerse the base in water or let water enter the air outlet or other openings.
Clean and rinse the water tank and mist nozzle with lukewarm water frequently to avoid mineral
build up.
Keep the nebulizer and water sensor free of mineral deposits. Remove water tank and empty the
reservoir. Clean the nebulizer and sensor with a soft brush (old toothbrush). Do not scrape the
nebulizer or water sensor. Do not clean with tools that have metal parts.
Leaving water to sit in the tank for more than a couple days may cause bacterial growth. Always
empty the tank if not planning to use for a few days even though the ceramic lter destroys any
bacterial growth in the tank.
TECHNICAL
SPECIFICATIONS
Model
Input voltage
Power consumption
Water tank capacity
SU-2550
AC 120V ~60Hz
0.43A/30W
2.5L
TROUBLESHOOTING
Check if unit is powered on.
Turn the mist intensity level higher (clockwise)
Check if water is in the tank.
If there is water in the tank, the water level in the
base may be too full. Unplug the unit, remove
tank and empty the water in the base.
Check if water tank is properly aligned in place.
Unit is not producing mist.