Nxtar NS200M User manual

Instruction –
NS Controller
Perimeter Intruder Detection System
Model NS200M
Security Controller
NS Controller

Thank you for purchasing the NXTAR NS200M
Security Controller. This remarkable component
has been engineered to provide its user with may
year of reliable sensing capabilities utilizing fiber
optics as its medium. Please take a few minutes
to read this manual thoroughly before you
connect and operate the NS200M.
As the operation may be multi-layered and the
configuration options are very flexible, you are
encouraged to discuss the requirements with your
NXTAR Specialist in your country for technical
assistance.
Perimeter Intruder Detection System
INTRODUCTIONS
FEATURES
Installation –
NS Controller
2
2 Zones
2 Individually calibrated zones to cover a
maximum of 600m of perimeter on fence
deployment , Powered by extremely high
powered, stable light source, to give you
constant and maintenance-free performance ,
all these housed in a strong cast aluminum
casing.
Intelligent Discrimination
High performance software to calibrated the
zones individually and the ability to monitor
them simultaneously. Equipped with
Intelligent discrimination to help eradicate
Nuisance Alarm and False Alarm to the
lowest possible industrial standard. The
NS200M is also able to identify the presence
of Global Noises without the presence of
weather station
100% Passive Outfield
NXTAR Systems is one of the few who is
able to achieve a 100% passive components
outfield. Our systems doesn’t require any
electrical powering once outfield. This is a
very strong feat as it requires no deployment
of electrical cables for powering and signal
amplification for long distance transmission.
It also enabled deployment within a faster.
Plug and Play
NXTAR enables the user and installer to
connect all fiber optics with SC connectors.
There is no need to expensive and fragile
splicer to connect the fiber cables to their
respective junctions/terminal boxes.
NS Controller

NXTAR Fiber Optic Intrusion Detection System is based on the theory of
“Interferometer”, utilizing fiber as a highly sensitive medium, indirectly or directly
sensing pressure, vibration. The detected signals will be sent back to controller for
further intelligent analysis, effectively discriminating the real human intrusion from
false/nuisance alarm caused by small animals or global noise.
All NXTAR NS System come equipped with a NC/ CC dry contact which enables a wide
range of security equipments to link up with our system. Upon triggering a TAMPER or
ALARM signal, the NS communication and monitoring unit will trigger the NC/ CC
contacts to perform its respective task. It can also be connected to speed dome cameras
to zoom in on its present location to see and record the intrusion.
We at NXTAR understand that it is almost impossible to demand a perimeter, especially
a big one, to be of the same landscape and environment. Therefore, the NS system can
accept Individual zone settings for finer monitoring resolution. The perimeter can be
segregated into as many zone as desired, but each should not exceed 100m by
1.5m for underground buried installation. To successfully
apply
the sensing fiber to
Perimeter Intruder Detection System
1.
2.
3.
SYSTEM CHARACTERISTICS
Installation –
NS Controller
1.5m for underground buried installation. To successfully
apply
the sensing fiber to
achieve good Signal to Noise ratio, the medium in which it is deployed must also be
uniform. This guide will provide our recommended installation methods and selection of
medium, and should be followed as closely as possible to achieve optimum results.
3
NS Controller

Perimeter Intruder Detection System
FRONT PANEL
Installation –
NS Controller
AB
4
TAMPER LED Indicator
When the LED is GREEN, it indicates
normal operation and there is no breach in
the fiber connection. It also signifies that
the controller is ready for Operation. When
LED is RED, it indicates that there is a
breach somewhere in the system. This may
be tampered or damaged by intruders.
Thorough inspection is required at the
respective zone or contact your dealers and
supplier for an inspection. User can also
refer to the operational software to detect if
tampering occurs at the Leading Fiber or
Sensing Fiber. User can refer to
“Installation – System Setting and
Calibration” for more details required.
Necessary action should be carried out
while the respective TO/TC contacts will
also be activated accordingly less than 5S.
AINTRUDER LED Indicator
When the LED is no lighting, it indicates
normal operation and that there is no
intruder in the perimeter or the detection
zones. When the LED is RED and blinking,
it indicates that is a Warning Signal. It also
indicates that there are some unknown
project approached or touched detection
area. When the LED is RED in any zone, it
indicates that there is a intrusion in that
detection zone. Necessary action should
be carried out while the respective NO/CC
contacts will also be activated accordingly
at real time.
B
NS Controller

Perimeter Intruder Detection System
BOTTOM PANEL
1
DC Inlet
Connect to DC Adapter or Supply. The NS200M can take 5Vdc, 1A to power
the system.
1
DATA Transmission Port
Installation –
NS Controller
234
5
Power Tamper LED warning
LED indicates warning when the DC Power is reversely connected.
2
6
5
Dry Contact
INTRUDER
There are 2 sets of dry contacts in this row. It is labeled “NO1/CC1” to “NO2/CC2”
to trigger other devices of Zone 1 to 2 respectively if there is a presence of intruder
in one of the zone.
TAMPER
There are 2 sets of dry contacts in this row. It is labeled “TO1/TC1” to “TO2 / TC2”
to trigger other devices of Zone 1 to 2 respectively if there is a tampering in any of
the zones. A check is required to see if there is a disconnection or breach in any of
the connection or fibers outfield.
ACCESS CONTROL
Activate Entrance Channel Setting for access control use.
4
DATA Transmission Port
The controller output uses a RS-232 interface. It allows the user to
communicate and calibrate the settings with a computer. After initial setting, it
can be disconnected to allow independent operation.
3
NS Controller
USB 2.0 to RS232 Cable.

Perimeter Intruder Detection System
Installation –
NS Controller
BOTTOM PANEL
Signal Input PD1-PD2
There are 2 sets of inputs to receive Tamper or Intruder signal from Zone
1 to 2. Please clean the connectors prior to connecting the SC connectors
into their respective socket here. Do not stare into the sockets and
6
Light Source Out LD1-LD2
This is the output for the light source to send its light pulse into the
connection. Do not stare into the output at any time during operation to as it
can caused permanent damaged to the eye.
5
Dry contact
Status NO1 & CC1 TO1 & TC1 NO2 & CC2 TO2 & TC2
Power off Shunt Shunt Shunt Shunt
Normal Open Open Open Open
CH1 TAMPER Open Shunt N/A N/A
CH1 INTRUDER Shunt Open N/A N/A
CH2 TAMPER N/A N/A Open Shunt
CH2 INTRUDER N/A N/A Shunt Open
Table 1 Dry contact status
6
NS Controller
Cleaning of SC/ APC Connectors
Upon removing the covers, the SC/ APC connector can be accessed.
Each SC/ APC connectors are to be cleaned individually with 99% alcohol
and lint-free clean swipes.
connectors at all time to prevent permanent damaged to the user’s eyes.

Perimeter Intruder Detection System
SYSTEM STRUCTURE
Installation –
NS Controller
ZONE 1
ZONE 2
Leading Fiber
Sensing Fiber
Controller
SJB
7
NS Controller
TJB Sensing Fiber

Perimeter Intruder Detection System
The objective of these tests is to verify that the NS200M Controller is working properly.
1) Make sure you have cleaned the connectors of LD with 99% Alcohol Solutions
and clean swipes before connecting it into the socket.
2) Make sure you have cleaned the two SC connectors of PD1 to PD2 with 99%
Alcohol Solutions and clean swipes before connecting them into their socket.
NOTE 1: The tip of the SC connectors are made of ceramic and are not to be
touched by bare fingers. When connecting, please ensure that the tip
does not touch the sides of the sockets!
4) Turn system on and wait for 5 seconds.
5) All the LED in the “TAMPER” should be GREEN. If any of the LEDs is RED,
please to check optics loop of detection.
6) Connect the controller to PC with RS232, and activate NSS for parameter setting.
7) Please take extra care when you see the label below. Direct exposure of the
eye to the tip of connectors can caused permanent damage to the user.
SYSTEM TESTING
Installation –
NS Controller
8
NS Controller

Perimeter Intruder Detection System
SPECIFICATIONS
Installation –
NS Controller
Controller:
1) Power Spec: DC 5V / 2A
Interface Spec:
1) RS-232 X 01pc
2) Relay Contact
i) 120Vac/ 10A - 250Vac/ 7A,
ii) 24Vdc/ 10A
3) Intruder LED x 02
4) Tamper LED x 02
5) Beeper x 01
9
NS Controller
5) Beeper x 01
Mechanical Spec:
1) Dimension: 260mm x 205mm x 44.6mm (L x W x H)
2) Net Weight: 1.2kg
Operation Conditions:
1) Operating Temperature - 20°C ~ 60°C for mainframe
2) Humidity (Non-Operating) 30% ~ 95% (non-
condensing)

Perimeter Intruder Detection System
DIMENSION
Installation –
NS Controller
10
NS Controller
Table of contents
Popular Controllers manuals by other brands

Grozone Control
Grozone Control The Simple One CLIMATE CONTROLLER Advanced user's guide

Conrad
Conrad 97 45 16 operating instructions

Delta Regis
Delta Regis BECT832-SSO-V4.0 Operation manual

IntesisHome
IntesisHome IHWFIPAN001R000 Installation sheet

Eaton
Eaton ELCM TC Series instruction sheet

dixell
dixell WING XW260K Installing and operating instructions