4 External powering scheme
5 Switch configuration
Please, make sure that switches are placed in the right position as per your desired settings.
Description
Follower in R1-R2 bus, a wired remote controller needs to be set as header (Default value)
Header in R1-R2 bus, a wired remote controller needs to be set as header
Temperature in Celsius (in the RC bus) (Default value)
Temperature in Fahrenheit (in the RC bus)
Low Power Mode (Default value)
WIFI power is limited (Default value)
Switch 3
This switch determines the performance of the device. Running in High Performance Mode means maximum consumption
and maximum device performance.
Switch 4
This switch determines the Wi-Fi range of the device. Maximum range is set by default. Consider that changing this switch
may affect to device Wi-Fi communication, happening a device in a running installation not to reach the current access
point or Wi-Fi network to which is connected.
In case no external supply is used: In very specific installations, AC port consumption may be overpassed, leading the
device to reboot. If that happened, decrease device consumption by using SW3 and SW4.
NOTE: Remember that you need to power cycle the climate system or the IntesisHome device for the changes in the
switches to be applied.
Important: If a wired remote controller of the AC
manufacturer is connected in the same bus,
communication may shut down. In case it
happens, use an external power supply connected
to the PS connector in our device to overcome this
situation.
Connect a NEC Class 2 or Limited Power
Source (LPS) and SELV rated power supply to
the device, respect the polarity. Apply always
a voltage within the range admitted and of
enough power (12V DC, min. 60 mA).