Set up USB Data Logger Interface
IMPORTANT: Do not connect the interface cable to your
PC until instructed to do so or the setup will not work.
A Insert the Omega Data Recorder
Software CD into your CD drive.
The CD should run
automatically, and the CD
Contents screen should appear.
If it does not, click the Start
button and choose Run. A dialog
box will appear, enter
D:\autorun.exe (If “D” is the
letter of your CD drive).
For Windows 7 users this
process will be a little different.
Click on the Window button in
the lower left corner of the
screen. This will bring up the
Start List. Type ‘Run’ in the
‘Search programs and files’ field.
In the next screen click on ‘Run’
at the top; this will open the
Run dialog. Enter
D:\autorun.exe.
B Click on the Install Omega
Software link on the CD
Contents screen to start the
install of the Data Logger
Software. The Install Omega
Software window will appear,
click on the Install Omega
Software link. Follow the on
screen prompts to complete the
installation. Click Back to Omega
CD Contents when completed.
See the Software Manual or go
online at www.omega.com for
additional information.
C To install the drivers for the
OM-CP-IFC200/OM-CP-IFC300,
click on the Drivers and Third
Party Tools link on the CD
Contents screen. In the next
window click on Install USB
Interface Drivers. A window
will appear prompting for a
directory and to start the
installation.
The default directory is
C:\Program Files\MTI-
USB\Datalogger Interface. If
you choose to change the
location of the install directory
click on the Change Install
Location button. Once you
have the install location set
click on the Install button to
start the installation.
OM-CP-IFC200/OM-CP-IFC300 For XP SP3/Vista/Windows 7
A On the OM-CP-IFC300, remove
the Warning Label to expose
the USB connector. (The OM-CP
-IFC200 will have an open
communication port.) Connect
one end of the USB cable to the
USB port of the OM-CP-IFC200/
OM-CP-IFC300.
B Connect the other end to a USB
port on your PC. When the
OM-CP-IFC200/OM-CP-IFC300
is plugged in, a New
Hardware Found message will
appear in the lower right corner
of your screen. The new drivers
will automatically configure
themselves for use with the
Interface cable. A message will
then appear that the new
hardware is installed and ready
to use.
The installation of the USB data
logger interface is complete.
Warning:
Install driver before
connecting this device.
1
Connect the USB Data Logger Interface
2
USB Data Logger Interface
Quick Installation Guide
Package Contents
OM-CP-IFC200
 USB Interface Device
 USB Cable
 3.5mm Audio cable
 Data Recorder Software
CD-ROM
 Quick Installation Guide
OM-CP-IFC300
 USB Interface Device
 USB Cable
 Data Recorder Software
CD-ROM
 Quick Installation Guide
 Software Manual
2.03.6
A To verify that the USB Interface drivers are installed properly,
check to ensure the Data Logger Software can recognize a
device.
B When the interface cable is connected to the PC the blue LED
power indicator light should be on. If the indicator light is not
on, unplug the interface cable, wait 5 seconds and plug it back
into the PC.
C Start the Omega Data Logger Software. (If necessary, see the
software manual for additional information on the software)
C Choose Select Comm Port from the Communication menu.
A sub-menu will appear listing the available communication
ports. If the USB driver install was successful, and the USB
interface is plugged into the PC, then USB1 should appear as
an option.
If multiple USB interface cables are connected to the computer
they will be listed USB1, USB2, USB3, etc. Use this menu to
select the proper device.
E The USB interface can be configured to work with most Omega
Data loggers by selecting the proper baud rate from the Select
Baud Rate option under the Communications menu. The baud
rate used by the logger is listed on its label. For example the
OM-CP-QuadTemp communicates at 115,200 baud, so 115,200
must be selected.
Contact US
Website
http://www.omega.com
E-mail Support
[email protected]
Phone
(800) 872-9436
Fax
(203) 359-7700
Address
Omega Engineering, Inc.
One Omega Drive,
PO Box 4047,
Stamford, CT 06907-0047
Test the Data Logger Interface Operation
3
Additional Information
For additional information or troubleshooting assistance, refer to the
User Guide on the Data Recorder Software CD-ROM or call
Toll Free (800) 872-9436.
D

This manual suits for next models

1

Other Omega Other manuals

Omega AQM-102 User manual

Omega

Omega AQM-102 User manual

Omega 92450 Instructions for use

Omega

Omega 92450 Instructions for use

Omega OM-22 User manual

Omega

Omega OM-22 User manual

Omega OM-DAQXL-1 Series User manual

Omega

Omega OM-DAQXL-1 Series User manual

Omega 21022 Instructions for use

Omega

Omega 21022 Instructions for use

Omega OM-CP-OM-CP-OCTPRO User manual

Omega

Omega OM-CP-OM-CP-OCTPRO User manual

Omega RDXL6SD User manual

Omega

Omega RDXL6SD User manual

Omega Om-ML Series User manual

Omega

Omega Om-ML Series User manual

Popular Other manuals by other brands

Perel SSE025 user manual

Perel

Perel SSE025 user manual

TERASAKI S100-NF instruction manual

TERASAKI

TERASAKI S100-NF instruction manual

Soundmask SM-DX-4800 operating manual

Soundmask

Soundmask SM-DX-4800 operating manual

AKO AKO-57615 quick guide

AKO

AKO AKO-57615 quick guide

Sony ECM-XYST1M operating instructions

Sony

Sony ECM-XYST1M operating instructions

MTP ST-172 instruction manual

MTP

MTP ST-172 instruction manual

Whirlpool 8535841 installation instructions

Whirlpool

Whirlpool 8535841 installation instructions

NEC AT-35 brochure

NEC

NEC AT-35 brochure

jablotron JA-80IR Prelimenary Manual

jablotron

jablotron JA-80IR Prelimenary Manual

ElectrIQ CD25PRO-LE user manual

ElectrIQ

ElectrIQ CD25PRO-LE user manual

American Bath Factory Sistine Stone Alcove installation guide

American Bath Factory

American Bath Factory Sistine Stone Alcove installation guide

Mackie FireWire owner's manual

Mackie

Mackie FireWire owner's manual

Cherry SmartTerminal ST-1275 operating manual

Cherry

Cherry SmartTerminal ST-1275 operating manual

LG GB108 Service manual

LG

LG GB108 Service manual

Tertium BlueBerry UHF user manual

Tertium

Tertium BlueBerry UHF user manual

marinco CHARGE PRO 28106 instruction manual

marinco

marinco CHARGE PRO 28106 instruction manual

iCarsoft BMM V1.0 user manual

iCarsoft

iCarsoft BMM V1.0 user manual

DU-HA 20114 installation instructions

DU-HA

DU-HA 20114 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.