OPlus OP-6502IP User manual


Contents
Summary...........................................................................................................................................................................................................1
Safety precautions............................................................................................................................................................................................1
Product introduction..........................................................................................................................................................................................2
Features.............................................................................................................................................................................................................2
Hardware interface introduction......................................................................................................................................................................3
Introduction......................................................................................................................................................................................................5
Packing list.........................................................................................................................................................................................................5
Basic network settings......................................................................................................................................................................................7
Wiring..................................................................................................................................................................................................................8
User-defined terminal parameters..............................................................................................................................................................9
Login web interface...........................................................................................................................................................................................9
Network parameters.......................................................................................................................................................................................10
Device parameters..........................................................................................................................................................................................10
Server parameters..........................................................................................................................................................................................11
Broadcast parameters....................................................................................................................................................................................11
Intercomparameters.......................................................................................................................................................................................12
Monitor parameters.........................................................................................................................................................................................13
Recording parameters....................................................................................................................................................................................13
Password modification ...................................................................................................................................................................................14
Port modification .............................................................................................................................................................................................14
Language settings...........................................................................................................................................................................................15
Restart device..................................................................................................................................................................................................15
Upgrade the firmware (Note: please do not upgrade the firmware without any special needs) ..........................................................16
System log .......................................................................................................................................................................................................16
Basic functions .............................................................................................................................................................................................17
Local intercom.................................................................................................................................................................................................17
Warmprompt...................................................................................................................................................................................................17
Remote intercom.............................................................................................................................................................................................17
Receiving broadcasts.....................................................................................................................................................................................18
Recording.........................................................................................................................................................................................................18
Engineering mode - volume adjustment without web access...................................................................................................................18
Troubleshooting............................................................................................................................................................................................19
Copyright statement.....................................................................................................................................................................................20

IP Digital Window Intercom UserManual
Summary
Safety precautions
•Please abide by the warning and the relevant safety tips.
•Please take this manual in convenient place for future reference.
Warning and Reminding
This symbol means there are potentialsafety issues, it may cause death or serious injury when incorrectly operating.
This symbol draws the attention to important operation and maintenance instructions.
Settings and Installation
•Avoid making the device wet.
•Do not expose the device to rain or water or other humid environment, as it may lead to fire or an electric shock.
•Do not use other power voltages than indicated on the power supply adapter.
•Use the device only with the indicated voltage to connect it.
•It may lead to fire or electric shock if using higher voltage.
•Do not damage, cut or twist the power cord.
•Keep the power cable away from any heating objects and do not put heavy things on it, as it may lead to fire or electric
shock.
Using the intercom
Please shut off the power supply immediately when the following phenomena happen. Please contact the supplier. It may cause fire
or electric shock when continuing to use it.
•When the device is smoking or smelling strange.
•When water or other things entered in the device.
•When the device fell or the device housing is damaged.
•When the power cord is damaged (copper wire is exposed or broken etc.).
•When the device is in a faulty state (cannot connect to the network, there is no sound etc.).
•Do not open or modify the device
•Don`t let other things enter into the device
• Don’t let metal items or inflammable objects enter the device, as this might result in fire or electric shock.
•Do not touch the device when lightning storms are active
•Do not put any liquid containers or metal objects on the device. If the container fell and liquids penetrated the device, this
may lead to fire or electric shock.
•The device contains parts under high voltage. Opening the cover or modifying the device may lead to fire or cause shock.
All maintenance and modifications to the device should be done by a qualified professional.
When not using the device for a longer period:
•Please shut down the power and pull out the power adapter when doingmaintenanceor not using the device for longer than
10 days.
www.opus-technologie.f r1

IP Digital Window Intercom UserManual
Product introduction
The IP digital window intercom uses embedded IP Audio digital network audio technology with intellectual property rights to realize
digital full-duplex intercom. The set is made of an internal and external window intercom module, equipped with power input,
communication interface, recording output port.
Internal window intercom External window intercom
Features
⚫Adopt single DSP multi-channel language auto-controltechnology, avoiding feedback and disturbances to realize real
digital full-duplex intercom.
⚫Using touchkeys with an ergonomic design, avoiding key-click sounds in the intercom conversation, and use light
indicators.
⚫Recognizingsound source, control environment noise, automatically adjust volume and restore the original sound.
⚫Providing three mode-scenes (quiet, standard, noisy), support one-button adjustment.
⚫Wiring between external and internal intercom over a single cable, avoiding poor contacts caused by moving the device on
the desk. This keeps the desk clear and tidy.
⚫Professional metal structure design, adopting hard metal housingto prevent resonance, purify and naturalize the sound to
make it transparent.
⚫Personalized and customized service message playback: “Hello, welcome”, “Thank you. See you next time”.
⚫Support for remote supervisor intercom, one-buttoncall to the terminalspecified by the server.
⚫Intelligent equipment self-check, detects the state of internal and external components. Abnormalities are indicated with a
local prompt.
⚫distinguished LED shows the state of the internal window intercom.
⚫Accessible via a Ethernet port and LAN network
www.opus-technologie.f r
2

IP Digital Window Intercom UserManual
Hardware interface introduction.
Internal window intercom Module 【Front】
①Network status indication: red light is offline, green light is online
②Gooseneck microphone socket: plug the gooseneck microphone and fix the screw.
③Loudspeaker: amplify the audio from the external window intercom.
④Voice broadcast button/ remote intercom button (left):
•When the intercom button ⑥is on (blue lightON):
•Press voice broadcast button shortly to broadcast "Hello, welcome" message
•Press long (1 second) to broadcast "Thank you, welcome next
time.". The broadcast button flashes green during broadcasting.
⑤Remote intercom button (right) : when the terminal is connected to the server, press button to make a call to the
supervisor intercom terminal specified by the server.
⑥Intercom button: press the button to communicate with the external window intercom, finishthe conversation by pressing
the button again. The intercom button light blue during conversation.
【Side】
①Scene mode adjustment switch:
3 scene modes are available:
1. noisy(to the front)
2. standard(in the middle)
3.quiet(to the back)
Standard is the defaultmode.
www.opus-technologie. fr 3

IP Digital Window Intercom UserManual
【connectionwiring】
①
②
③
④
Power interface: connect with 12V/1.5A power.
Network interface: insert the cable to switcher
Analog audio output interface: output analog audio, connect with DVR or IP camera.
External window intercom interface.
【External window intercom module】
①Loudspeaker/MIC:
Loudspeaker:amplify the audio from the internal window intercom
Microphone:pick up the audio at the external window intercom module
Connector to the internal window intercom module
②
www.opus-technologie. fr 4

IP Digital Window Intercom UserManual
Introduction
Packing list
The Window intercom system includes the following accessories.
Please check following parts. Contact your reseller if any parts are missing.
(1)Internal window intercom module 1 set
(2)External window intercom module 1set
(3)Gooseneck microphone (DC-300B) 1PCS
(4)Power adapter(12V/1.5A)1PCS
(5)Wire binder(3*100mm)3PCS
(6)Self adhesive cable clamp (HC-100) 3PCS
www.opus-technologie. fr 5

IP Digital Window Intercom UserManual
6
(7)Wire terminal (3.81-2P) 1PCS
(8)Bushings (cable guidance) 1PCS
(9)EV-cotton (SPEV-63)1PCS
(10)Installationmanual 1PCS
(11)Certification 1PCS
www.opus-technologie.fr

IP Digital Window Intercom UserManual
Basic network settings
Using the Terminal Scanning Tool
1. Locate and run “DevConfigTool.exe” in the folder [optical disc:\tool software\ ].
Enter the default password “123456”.
2. Select the right tab【Mandatory config】,and fill out the correct parameters in the【terminal parameters】section.
Click "send parameters" button to complete the IP parametersSettings.
Note:
1. When using the windows 7 system, please use the administrator mode, and switch off the firewall and any 3rd
party firewall software.
2. This scanning tool can only be used when the computer and intercom are on the same network. Please ensure
that the computer and the target intercom are the only devices connected to the network or use a direct
(crossover) cable between computer and intercom.
Using the intercom built-in WEB page
Use a web browser and navigate to the Webpage of the IP digital window intercom. The default IP address is http://192.168.1.101.
Make sure you set the IP address of your computer to a correct static IP addressin the same range (e.g. 192.168.1.50 with a subnet
mask of 2545.255.255.0). Accordingto the situation, modify each parameters of the network settings. Click “save” when ready.
For specific operations, please refer to the user-defined terminal parameters.
www.opus-technologie. fr 7

IP Digital Window Intercom User Manual
Wiring
1. Connect the connector of the power adapter to the power interface of internal window intercom (red colored connector).
2. Connect the connectorof the external window intercom module with the correspondingconnectorof the internal window
intercom module.
3. Connect the Ethernet LAN cable to the RJ45 connector of the internal window communication module.
www.opus-technologie.f r8

IP Digital Window Intercom User Manual
9
User-defined terminal parameters
Login web interface
Use a web browser and navigate to the IP address of the IP internalwindow intercom module (factory default is http://192.168.1.101),
then press Enter.
Enter user name and password in the login window of the Web page (the default is : admin, password : Rdc070#*).
After pressing Enter, you arrive in the configurationweb page of the IP internal window intercom module.
www.opus-technologie. fr

IP Digital Window Intercom User Manual
Network parameters
The parameters have the following meanings:
Connection type You can choose to set a static IP manually or obtain an IP automaticallyfrom
DHCP server
MAC address The physical address of the terminal. This cannot be modified
IP address Terminal IP address, factory default is 192.168.1.101
Subnet mask The subnet mask of the LAN network.
Default gateway The gateway of the network
Preferred DNS server IP address of the preferred domain name resolver on the network
Alternate DNS server IP address of the alternate domain name resolver on the network
Device parameters
The parameters have the following meanings:
The device number Terminal ID, this number identifies the intercom module when more than one
intercom is in the network. Range 1-999, the factory default is 1.
Receive port Device communication port
Power-on local
detection
When Enabled, the device will automatically detect whether the microphone and
speaker are working properly by sending out a tone during startup.
www.opus-technologie.f r10

IP Digital Window Intercom User Manual
Server parameters
The parameters have the following meanings:
Preferred server
The IP address of the preferredserver for this intercom, the factory default
is 192.168.1.13.
Most of the advanced functions of the intercom depend on the server to
work properly.
Standbyserver When the preferred server is not available, the intercom will log in to the
standby server.
FTP Name, FTPPassword
FTP Name: The factory default is admin;
FTP Password: The factory default is Rdc070#*.
Used in the device management(the length of the user name or password
can’t more than 9 characters, English, number,-_*#!@$%^&.+.
Request Login Interval time When the intercom is offline, this timer will define the interval of login
requests that are sent to the server.
Broadcastparameters
The parameters have the following meanings:
Encoding format The encoding format of the host during broadcast, controlled by the server.
Sampling rate The sampling rate of the host during broadcast, controlled by the server.
Output Volume The volume of the audio output when the host is broadcasting, controlled
by the server.
Audio Output
When the broadcast is configured, the audio is being output to the internal
or external unit or to the internal and external units.
Both sides: When broadcasting, the sound is being output on the speaker
www.opus-technologie.f r11

IP Digital Window Intercom User Manual
of internal and external units.
Only inside:When broadcasting,the sound is being output on the speaker
of the internal unit only.
Only outside:When broadcasting, the sound is beingoutputon the speaker
of the external unit only.
Intercom parameters
The parameters have the following meanings:
Encoding format The encoding format of the host during intercom, controlled by the server.
Sampling rate The sampling rate of the host during intercom, controlled by the server.
Network intercom input
volume
The volume of the network input source during intercom.
Network intercom Output
Volume
The volume of the network output source during intercom.
Internal output volume The output volume of the internal window intercom during intercom.
External output volume The output volume of the external window intercom during intercom.
Prompt tone volume
The volume of the key-clicks, button tone, busy tone, hanging tone, etc.
during intercom; the volume of welcome and Goodbye prompt during local
intercom.
When initiating intercom As the intercom initiator, you can set whether allow to hang up the
intercom.
When receivingintercom As the intercom receiver, you can choose to answer automatically or
manually, allow to hang up or forbid to hang up.
Whether to enableoffline
intercom
When Checked:when offline,the terminal can call the target set in the
offline parameters
www.opus-technologie.f r12

IP Digital Window Intercom User Manual
Left-click call: when offline, enter the IP address corresponding to the
remote intercom (left) button;
Right-click call: when offline, enter the IP address corresponding to the
remote intercom (right) button;
Port cannot be modified except for special situations (the defaults is 2046)
Monitor parameters
Input volume: The volume of the host during monitoring.
Recordingparameters
The parameters have the following meanings:
Digital RecordingMode
No recording mode:No recording function and right button of internal unit
without any function.
Automatic recording mode:Automatically recording when internal unit talk
with external unit, meanwhile right button of internalunit without any
function.
Open recording mode:Default recording when internal unit talk with external
unit, while users can press right button of internal unit to end or restart
recording.
Turn off recording mode:Default not recording when internal unit talk with
external unit, while users can press right button of internalunit to end or start
recording.
Note:The recording file will be generated in the recording tool and saved in
the specified folder.
www.opus-technologie. f r 13

IP Digital Window Intercom User Manual
14
Analog Output Volume Set the output volume for analog recording.
Digital Output Volume Set the output volume for digital recording.
Enable digital recording
Check “Enable Digital Recorder” to enable intercom 24-hour digital
recording.
Recording server: Enter the IP address and port of the digital recording
server. After checking “Enable Digital Recorder” , the system will
automatically obtain it.
Digital recording format: Set the output format of digital recording, only 8K
PCM format is supported for the moment.
Password modification
You can change the web page login-in account and password in the WEB management parameters, it will be effective after
clicking on “Save”.
Port modification
You can change the port of the WEB access. When not using port 80, please add the corresponding port behind the address
when accessing this WEB page. (e.g.: if the port is 8888, the access address will be http://XXX.XXX.XXX.XXX:8888.
www.opus-technologie.f r

IP Digital Window Intercom User Manual
Language settings
You can switch the Web page language between Chinese and English, save the modification and restart the intercom to activate
the changes.
Restart device
Restart the device
Note: the all modified parameters on the web page will be effective after restarting the device.
www.opus-technologie. fr15

IP Digital Window Intercom User Manual
16
Upgrade the firmware (Note: please do not upgrade the firmware without any special needs)
Click “System Tools” and “Upgrade Firmware” to enter the firmware upgrade page.
Click on “Into Firmware Upgrade” to put the device in firmware upgrade mode.
System log
The logfile contains all system events.
Click “Clear All The Log” to empty thelog.
www.opus-technologie.fr

IP Digital Window Intercom User Manual
17
Basic functions
Local intercom
After connecting the internal and external window intercom modules, turn on the power.
Press the intercom button of internal window intercom (the blue light goes ON). The internal window intercom can perform digital
full-duplex HD intercom with the external window intercom. Press the intercom button again to end the intercom (the blue light
goes OFF).
In coordination with an IP HD recording server, full-duplex 32K or 16K HD intercom can be achieved.
Warm prompt
During intercom conversation, press shortly on the voice broadcast button (left button). The window intercom system will
automatically broadcast the welcome prompt "Hello, welcome". Press longer on the left button to broadcastthe goodbye prompt
"Thank you, welcome next time." Press the button again or short press any other buttons to end the prompt during
broadcasting.
Remote intercom
When the internal window intercom is online, press left or right remote intercom button to call the different target terminals
specified by the server.
In the terminal setting dialog box of the service software, set the target called by terminal. The Call Sequence button mapping
order corresponds to the left button, the Extended Call Sequence button mapping order corresponds to right button.
After the above operations are completed, if the called terminal is idle, the terminal will play a waiting tone while waiting for an
answer from other party, and the called terminal will play a ringing tone. If the called terminal is busy or refuses to answer, the
calling terminal will play a busy tone.
Note: The default call is the intercom terminal with ID number 001. Multiple call objects can be set in the server. When
the called object is busy, the call can be automatically transferred to the next object.
www.opus-technologie. fr

IP Digital Window Intercom User Manual
18
Receiving broadcasts
Are automatically answered without pressing any button.
Recording
Analog recording
The internal window intercom can output analog audio and be connectedto a DVR to automatically record on the hard disk of
the recorder recorder.
Network recording
In the WEB page recording parameters, Check "Enable Digital recorder", and check “Open talk recorder” on the “Terminal talk”
of “Parameter 1” of “Server Advanced settings”
When the window intercom system is online, the IP window intercom will automatically send the audio stream to the server
during the conversations, realizing a 24-hour recording. The recording file can be queried, retrieved and played back in the
PC-side recording tool.
Local Intercom Recording
In the WEB page recording parameters, set “digital recording mode” and check "Enable Digital recorder" . During the internal
unit talk with external unit , the recording file is generated according to the selected recording mode, and can be queried,
retrieved, and played in the recording tool.
Engineering mode - volume adjustment without web access
1 ) When the device is in the standby state, long press the intercombutton and the left button at the same time
2) Release the button after hearing3 key clicks and the intercombutton is ON ,enter the engineeringmode(the left and right
button always ON , the intercom button flashing)
3 ) Press the left button to adjust the volume of internal unit : click once volume +, long press volume-.
Press the right button to adjust the volume of external unit : click once volume+,long press volume-.
4) After adjusting the volume , long press the intercom button and release after hearing 2 jkey-clicks .At this time, all the button
lights are off, and the new volume levels are saved.
www.opus-technologie.fr
Table of contents