manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PACH & COMPANY
  6. •
  7. Intercom System
  8. •
  9. PACH & COMPANY QUANTUM Q5VOIP User manual

PACH & COMPANY QUANTUM Q5VOIP User manual

•Missing Parts, contact Pach and Company 1-888-678-
7224
•Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
•24 Months warranty for complete system
•6 Months warranty for Printed Circuit Board
•Manuals, management software, catalog are on CD or
download at www.pach-co.com
Exit program, cancel call
25
Keypad beep
0= disable (default)
1=enable
Save program
26
Door beep
0= disable
1= enable (default)
00
Change master code (0000
is default)
27
Talk time (060-240
second). Default=60
second
01
Add new forwarding
tenant’s directory
28
Unlock relay1 time
(12-99 second).
Default= 12 second
02
Edit existing tenant’s
directory
29
Unlock relay2 time
(12-99 second).
Default= 12 second
03
Delete existing tenant’s
directory
30
Call Forwarding
0= disable 1= enable
04
Clear all forwarding
tenant’s directory
31
Call forwarding time
05-60 second
05
Call Forwarding
32
Forwarding directory
0-9
06
New access code
33
Temporary code
07
Delete access code
34
Special code
08
Clear all access code
35
Temporary card
09
Access code digit (4-8
digit). Default is 4-digit
36
Special card
10
Add new card
37
Initiate premise call
0=**, 1=## (default)
11
Delete card
38
System acknowledge
(0-9). Default= 3
12
Clear all card
39
Remote access
0= disable
1=enable (default)
13
Set time
40
DTMF relay 1 (1-9).
Default=9
14
Set date
41
DTMF relay 2 (1-9).
Default=8
15
Initializing event recording
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code
24 is enable
4= turn relay 2 on and off
On=7, Off=6
16
AUS= auto unlock schedule
(0-9 schedule)
43
DND: do not disturb
time zone (0-9)
17
TMZ= time zone. 20 TMZ,
00-20.
44
Disable Time zone relay
1, 2 or both
18
HLD= holiday zone. 20
HLD, 1-20
45
Relay 1 and 2 unlock
timer
20
AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AUXIN1
46
Firmware version
21
AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AUXIN2
48
PBX enable. Default=
disable
22
Do not disturb
0= disable (default), 1=
enable
23
Lock-out Count
49
Edit Access code
24
Alarm
0= disable
1= local beep for 60 seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
50
Erase the memory to
factory default
51
Welcome screen
Log on to programming: Press
and simultaneously then release,
the welcome message will stop
scrolling (repeat if screen still scrolls)
enter 4-digit “MASTER CODE” (0000
is default), the screen will show:
Select the “Function Code” from the
table
OPERATION
Opening the door remotely press (relay 1) or (relay 2)
Opening the door with the access code press (display screen
will stop scrolling) then press a valid 4-digit access code.
Extending talk time tenant must press from the phone after the
time out warning beep.
Calling into the system from premise location (Intercom)
1. Press or depending on function code 37, then
press to communicate with the person
Calling into the system from remote location:
Enable function code 39
1. Call the system phone number, hear one beep if the system
answering the call.
2. Press then 4-digit master code, hear one short beep
3. Press to establish two way communication
4. Press or to release the door.
Call waiting: function code 38 must be set 1-9 and function code 39
can be set either 1 or 0, press on your phone to transfer between
calls
See Function Code 37
Premise
Relay 1
Relay 2
Open cycle
##9/**9
##5/**9
Open hold
##8/**8
##4/**4
Close
##7/**7
##3/**3
OPERATION
TO CALL FROM THE SYSTEM
1. INTERCOM MODE PRESS
2. CALL FORWARDING MODE, press to scroll name from A-Z or
to scroll name from Z-A then press to call name selected.
Opening the door remotely press (relay 1) or (relay 2)
QUANTUM Q5VOIP SERIES
PACH AND COMPANY INC. QUICK GUIDE
1. INPUT POWER 12VAC 40VA SUPPLIED (voltage measurement must be (12.5-14.0 VAC)
OR 12VDC 2A adjustable power supply (voltage measurement must be 13.5-14.0 VDC)
2. 12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) WARNING: THIS IS NOT INPUT POWER
3. DOOR 2 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE
4. DOOR 1 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE
5. TELEPHONE OUT (TO ANALOG PHONE DEVICE)
6. TELEPHONE INPUT FROM AATA2 NO. 15
7. AUX 1 AND AUX 2 FOR EXIT SWITCH, LOOP DETECTOR OR ANY INPUT DEVICE WITH DRY CONTACT OUTPUT.
8. DOORS1 AND DOORS 2 SENSOR. WARNING: THESE ARE NOT DOOR CONTACTS
9. RS-485 PORT, CONNECT TO SLAVE UNITS (USCR, UCRM, USKP AND USKPR) UP TO 8 UNITS
10. 26-WIEGAND INPUT. PROPRIETARY CARD READER IS BUILT-IN ON THE QC SERIES. DISCONNECT THE BUILT-IN READER IF YOU
ARE USING YOUR OWN CARD READER.
11. FACTORY USE “ONLY” TO POWER THE QWCM IP MODULE AND FAN. WARNING: “DO NOT USE THE +12VDC POWER TO POWER
ANY OTHER DEVICES”.
12. AATA2 INPUT POWER 5VDC 3.0A (SUPPLIED)
13. AATA2 INTERNET CONNECT TO ROUTER OR SWITCH
14. AATA2 LAN CONNECT TO QWCM (#17)
15. AATA2 PHONE 1 ANALOG DIAL TONE.
16. QWCM POWER AND COMMUNICATION CONNECT TO (#11 12VDC POWER) AND (#18 RS-232). DO NOT UPLUG THIS CONNECTOR
WITH POWER ON FACTORY PREWIRED
17. QWCM ETHERNET PORT CONECT TO ROUTER OR SWITCH.
DO NOT CONNECT TO AATA2 NO. 14
18. RS-232 CONNECT TO (#16 ON QWCM) FACTORY PREWIRE
Technical Support is available
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224
Technical Info and complete manual are available online
www.pach-co.com
AATA2 ACTIVATION
www.ooma.com/activate
Nominal monthly fees and taxes required
based on zip code.
TURN OFF THE SYSTEM’S
POWER BEFORE CONNECTING
OR DISCONNECTING ANY
DEVICES

Other manuals for QUANTUM Q5VOIP

1

This manual suits for next models

2

Other PACH & COMPANY Intercom System manuals

PACH & COMPANY Aegis 7000 Plus Assembly instructions

PACH & COMPANY

PACH & COMPANY Aegis 7000 Plus Assembly instructions

PACH & COMPANY PAC-7000VFF Assembly instructions

PACH & COMPANY

PACH & COMPANY PAC-7000VFF Assembly instructions

PACH & COMPANY AeGIS NPB9000P Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS NPB9000P Series Assembly instructions

PACH & COMPANY AeGIS 8000 PLUS Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 8000 PLUS Assembly instructions

PACH & COMPANY AeGIS 4000 Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 4000 Assembly instructions

PACH & COMPANY 7000SC User manual

PACH & COMPANY

PACH & COMPANY 7000SC User manual

PACH & COMPANY Aegis 7000 Plus User manual

PACH & COMPANY

PACH & COMPANY Aegis 7000 Plus User manual

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY QUANTUM QVOiP SERIES User manual

PACH & COMPANY

PACH & COMPANY QUANTUM QVOiP SERIES User manual

PACH & COMPANY AeGIS 8000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 8000 Series Assembly instructions

PACH & COMPANY QUANTUM Q7000VOIP Series User manual

PACH & COMPANY

PACH & COMPANY QUANTUM Q7000VOIP Series User manual

PACH & COMPANY Quantum Q9000iP Series User manual

PACH & COMPANY

PACH & COMPANY Quantum Q9000iP Series User manual

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY AeGIS 7000S Series User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000S Series User manual

PACH & COMPANY AEGIS 7250P Assembly instructions

PACH & COMPANY

PACH & COMPANY AEGIS 7250P Assembly instructions

PACH & COMPANY Quantum QR5 Series User manual

PACH & COMPANY

PACH & COMPANY Quantum QR5 Series User manual

PACH & COMPANY QUANTUM QC1 Assembly instructions

PACH & COMPANY

PACH & COMPANY QUANTUM QC1 Assembly instructions

PACH & COMPANY AeGIS 7000SV User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000SV User manual

PACH & COMPANY QUANTUM QC Series User manual

PACH & COMPANY

PACH & COMPANY QUANTUM QC Series User manual

PACH & COMPANY AeGIS 7000V Series User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000V Series User manual

Popular Intercom System manuals by other brands

Equipos Europeos Electrónicos WBS-202 owner's manual

Equipos Europeos Electrónicos

Equipos Europeos Electrónicos WBS-202 owner's manual

ACO CDNP6ACC instructions

ACO

ACO CDNP6ACC instructions

Toa EXES 6000 CP-66 Installation handbook

Toa

Toa EXES 6000 CP-66 Installation handbook

SCS Sentinel SOFIA M7E8 W Installation and user manual

SCS Sentinel

SCS Sentinel SOFIA M7E8 W Installation and user manual

Paxton Access 351-110-US manual

Paxton Access

Paxton Access 351-110-US manual

Koch TC40/alu user manual

Koch

Koch TC40/alu user manual

Speco VDP-6000 Specifications

Speco

Speco VDP-6000 Specifications

CyberData 11214 Operation guide

CyberData

CyberData 11214 Operation guide

Opus OP-6505B user guide

Opus

Opus OP-6505B user guide

PS Engineering PAR200B Pilot's guide and operation manual

PS Engineering

PS Engineering PAR200B Pilot's guide and operation manual

Mobotix T24 System manual

Mobotix

Mobotix T24 System manual

Aiphone GT-1C7W Operation manual

Aiphone

Aiphone GT-1C7W Operation manual

Akuvox E16 Series Administrator's guide

Akuvox

Akuvox E16 Series Administrator's guide

Security Brands ASCENT X1 quick start guide

Security Brands

Security Brands ASCENT X1 quick start guide

Steren Platinum Series instruction manual

Steren

Steren Platinum Series instruction manual

CyberData 11308 Installation quick reference

CyberData

CyberData 11308 Installation quick reference

Panasonic VL-SW102BX operating instructions

Panasonic

Panasonic VL-SW102BX operating instructions

Telikou BK-601 instruction manual

Telikou

Telikou BK-601 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.