4
FEATURES & SPECIFICATIONS
FEATURES XPA1000 XPA600
Power Output 500 Watts Per Channel 300 Watts Per Channel
Design Class D 93% Efcient
Inputs Balance and Unbalanced Inputs
Outputs Unbalanced Loop Line Output to Another Amplier
12V Trigger For Remote Turn On
12V Trigger Out to Trigger External Device
70V/100V Selectable Rear Panel Swit
IR Remote IR Remote Included/ Hard Wired IR Receiver/ Codes Availab
RS232 RS232 Querries & Commands Available
Output Level Meter Front Panel Status; Protection & Warning LEDs
Chassis Design 1U Rack
Voltage Multi-Voltage: AC115/230V
SPECIFICATIONS XPA1000 XPA600
Power Output 500W X2 300 W X2
THD 1% (Rated Power)
Signal To Noise >90dB A Weighted
Freq Response 20Hz - 22kHz +0/-2dB
Adjustable Level Min - Max
Line Level Input
Sensitivity 510mV
Thermal Protection Yes
Short Protection Yes
Dimensions (WxHxD) 435mm x 44mm x 240mm 17" x 1.7" x 9.4"
Weight 4.2Kgs / 9.25lbs
3
SAFETY
13. Cleaning – Clean only with dry cloth.
14. Power Lines – An outdoor antenna should be located away from the power lines.
15. Nonuse Periods – The power cord of the appliance should be unplugged from the outlet when left unused for a long
period of time.
16. Accessories – Only use attachments/accessories specied by the manufacturer.
17. Object and Liquid Entry – Care should be taken so that objects do not fall and liquids are not spilled into the enclosure
through openings.
18. Damage Requiring Service – The appliance should be serviced by qualied service Personnel when:
A. The Power-supply cord or the plug has been damaged; or
B. Objects have fallen, or liquid has spilled into the appliance; or
C. The appliance has been exposed to rain; or
D. The appliance does not appear to operate normally or exhibits a marked change in performance; or
E. The appliance has been dropped, or the enclosure damaged.
19. Servicing – The user should not attempt to service the appliance beyond that described in the operating instructions.
All other servicing should be referred to qualied service personnel.
7. Wall or Ceiling Mounting – The appliance should be mounted to wall or ceiling only as recommended by
the manufacturer.
8. Ventilation – The appliance should be situated so that its location or position does not interfere with its proper
ventilation.For example, the appliance should not be situated on a bed, sofa, rug or similar surface that
may block the ventilation openings; or, place in a built-in installation, such as a bookcase or cabinet that
may impede the ow of air through the ventilation openings.
9. Heat – Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
( including ampliers ) that produce heat.
10. Power Sources – The appliance should be connected to a power supply only of the type described in the operation
instructions or as marked on the appliance.
11. Grounding or Polarization – Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wide blade or the third grounding prong are provide for your
safety. If the provided plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
12. Power-Cord Protection – Power supply cords should be routed so that they are not likely to be walked on or pinched by
items placed upon or against them, paying particular attention to cord at plugs, convenience
receptacles, and the point where they exit from the appliance.
XPA1000-600 Amp manual R1.indd 4-5 7/20/22 10:01 AM