Osram e:cue LCE2-mx User guide

AM19398003I
Lighting Control Engine 2 mx
Setup Manual /
Installationsanleitung
AN OSRAM BUSINESS

2
AM19398003I
Lighting Control Engine 2 mx Setup Manual (original issue)
Lighting Control Engine 2 mx Installationsanleitung
(Originalversion)
Edition/Ausgabe: 27.06.18 [EN_DE_LCE2-mx_Setup_v1p9]
Published by / Herausgegeben von:
OSRAM GmbH
Karl-Schurz-Strasse 38
33100 Paderborn, Germany
www.ecue.com
www.traxontechnologies.com
©2018 OSRAM GmbH, BU Lighting Solutions
All rights reserved / Alle Rechte vorbehalten

3
Read the Setup Manual and
the Safety instructions
carefully. Subject to
modification without prior
notice. Typographical and
other errors do not justify any
claim for damages. All
dimensions should be
verified using an actual part.
Modification of the product is
prohibited.
This manual is designed for
electricians, system
administrators, and product
users.
All product names mentioned
in this manual are trademarks
of their respective owners.
Except for internal use,
relinquishment of the
instructions to a third party,
duplication in any type or
form - also extracts - as well
as exploitation and / or
communication of the
contents is not permitted.
Lesen Sie die
Installationsanleitung und
das Heft
„Sicherheitshinweise“
sorgfältig durch. Alle
Änderungen vorbehalten.
Rechtschreibfehler oder
andere Fehler rechtfertigen
keinen Anspruch bei
Schäden. Alle Maße sollten
an einem realen Gerät
überprüft werden.
Modifikation des Produktes
ist verboten.
Diese Anleitung richtet sich
an Installateure, IT-
Administratoren und
Produktanwender.
Alle in dieser Anleitung
genannten Bezeichnungen
von Erzeugnissen sind
Marken der jeweiligen
Hersteller.
Außer für interne Verwendung
ist die Überlassung dieser
Anleitung an Dritte, die
gesamte oder auszugsweise
Veröffentlichung, Verwertung
oder Mitteilung in jeglicher
Art und Form nicht gestattet.

4
Table of Contents / Inhalt
Table of Contents / Inhalt
English 8
1 Security Instructions 9
1.1 Symbols 9
1.2 General Security Instructions 9
2 General Device Description 10
2.1 LCE2-mx 11
2.2 Delivery Content 11
2.3 Optional Accessories 12
2.4 Connectors and Interfaces 12
3 Product Specifications 13
3.1 Technical Data 13
3.2 Engine 14
4 General Remarks 14
4.1 Transport 14
4.2 Unpacking 15
4.3 Maintenance and Repair 15
4.4 Support 16
4.5 Warranty Regulations 16

5
Table of Contents / Inhalt
4.6 Disposal 16
5 Installation 17
5.1 Mounting 17
5.2 Power Supply 17
6 Configuration 18
6.1 LCE2-mx Operation 18
6.2 Setup 19
6.3 Network Settings LCE2-mx 19
6.4 Network Settings SYMPHOLIGHT 20
6.5 Network Settings LAS 22
7 Certifications 23
Deutsch 24
8 Sicherheitshinweise 25
8.1 Symbole 25
8.2 Allgemeine Sicherheitshinweise 25
9 Allgemeine Beschreibung 27
9.1 LCE2-mx 27
9.2 Lieferumfang 27
9.3 Optionales Zubehör 28
9.4 Anschlüsse und Schnittstellen 28

6
Table of Contents / Inhalt
10 Produktdaten 29
10.1 Technische Daten 29
10.2 System 30
11 Allgemeine Hinweise 31
11.1 Transport 31
11.2 Entpacken 31
11.3 Wartung und Reparatur 31
11.4 Technischer Support 32
11.5 Garantiebestimmungen 32
11.6 Entsorgung 33
12 Installation 33
12.1 Montage der LCE2-mx 33
12.2 Stromversorgung 34
13 Konfiguration 34
13.1 Betrieb LCE2-mx 35
13.2 Setup 35
13.3 Netzwerkeinstellungen LCE2-mx 36
13.4 Netzwerkeinstellungen SYMPHOLIGHT 37
13.5 Netzwerkeinstellungen LAS 39
14 Zertifizierung 40

8
English
English

9
Security Instructions
1 Security Instructions
Make sure that the environmental, mounting, and installation
prerequisites are met. This manual should be kept at a safe place
and in reach of the device.
1.1 Symbols
!
The exclamation mark warns about possible damage of
the device itself or connected devices.
i
The information symbol gives general hints and informs
about handling and procedures for use of the device.
1.2 General Security Instructions
!
To prevent electric shock hazard or damage to the
equipment, disconnect the power cord to remove
power from the server. Portions of the power supply
and some internal circuit remain active until power is
removed.
!
Device components inside the system can reach high
temperatures. Do not open the system while in
operation. Repairs may only be carried out by
authorized, specially trained personnel. When in
doubt, contact OSRAM service.

10
General Device Description
2 General Device Description
e:cue engines are a perfect platform for building dynamic,
effective, and reliable lighting applications. These engines are the
functional backbone of lighting installations controlling fixtures,
!
To avoid short circuits, keep paper clips, screws, and
staples away from connectors, slots, sockets, and
circuitry.
!
Avoid dust and humidity. Do not place the device in
any area where it may become wet.
i
Installation and maintenance of this product must be
performed by qualified individuals who are
knowledgeable about the procedures, precautions,
and hazards associated with the product.
i
To prevent the device from overheating, only operate
it in well-ventilated environment. Cooling fins may not
be obstructed. Do not install next to heat emitting
sources or in a place subject to direct sunlight.
i
Seek professional assistance before using an adapter
or extension cord. These devices could interrupt the
grounding circuit.

11
General Device Description
interacting with user terminals, and executing shows. e:cue
engines are built for steadiness, long-term use, and flexibility. They
are feature-rich and benefit from many years pioneering work in
the field of lighting control.
2.1 LCE2-mx
Designed to control small to medium projects, the Lighting Control
Engine 2 mx (LCE2-mx) is a high performance server with two
e:cue software applications installed. As a central control unit, this
versatile lighting control server orchestrates all devices and
fixtures within a project. With the ability to output e:net and the
capability to integrate various external engines, triggers, and other
desired devices and content, the LCE2-mx is the ultimate solution
for medium-sized projects: from automation to DALI projects up to
architectural illumination. With e:cue SYMPHOLIGHT and e:cue
Lighting Application Suite, the LCE2-mx offers two fully equipped
professional lighting control solutions. The LCE2-mx can be
mounted on DIN rails with the optional DIN rail adapter brackets,
on walls, and in 19 inch racks mounted on a rack drawer.
2.2 Delivery Content
Delivery content of the e:cue Lighting Control Engine 2 mx -
Product number AM19398003I:
—Lighting Control Engine 2 mx
—Microsoft® Windows 10™
—LCE2-mx Setup Manual / Installationsanleitung
—e:cue Lighting Application Suite
—e:cue SYMPHOLIGHT
—License dongle (integrated)

12
General Device Description
2.3 Optional Accessories
—External 24 V power supply unit, mountable on DIN rails -
Product number AA5574300HA
—TX Connect Data Cable (RJ45) - Product number AA556130055
2.4 Connectors and Interfaces
The LCE2-mx features a SIM card slot and 4 antenna ports for
optional modem addition to the device.
On / O2 x RS-2322 x USB 2.0Power Supply port
Cooling Fins
Audio Line-Out 2 x USB 3.0DVI 2 x RJ45HDMI
Antenna Antenna

13
Product Specications
3 Product Specifications
3.1 Technical Data
Product number AM19398003I
Dimensions (L x W x H) 182 x 167.6 x 54 mm housing
Weight 1.465 kg
Power supply External 9 ... 36 V DC input w/
reverse polarity protection, OCP,
and OVP
Power consumption 60 W max.
Operating temperature 0 ... 60 °C, ambient w/ air
Storage temperature -10 ... 70 °C,
Relative humidity 0 ... 80% non-condensing
Protection class IP20, not designed for outdoor use
Housing Aluminum alloy
Mounting Wall mounting
Battery Yes (1)
Cable length max. 3 m (except DMX, Ethernet)

14
General Remarks
Certifications CE
3.2 Engine
Operating system Microsoft® Windows 10™
System connection
ports
2 x RJ45 Ethernet for GbE (e.g. e:net +
Internet)
2 x RS-232
2 x USB 2.0 and 2 x USB 3.0
HDMI
DVI / VGA (Through DVI-I
-use only with single link DVI cables)
Audio Line-Out
SIM card slot
4 x Antenna (optional)
2 x PCI Express Mini-card Slots
1 x integrated License dongle
Data storage 128 GByte SSD SATA HDD
1 x SATA
4 General Remarks
4.1 Transport
Only transport the LCE2-mx in its original packaging. This protects
the server from damage.

15
General Remarks
4.2 Unpacking
Only unpack the LCE2-mx at its installation location. To protect the
device against condensation water, unpack it and wait until all
moisture remaining in the device has evaporated. Condensation
can occur when the device is moved from a cold to a warm
location. Keep the packaging for use in case of further transport.
Inspect all parts for completeness regarding chapter „2.2 Delivery
Content“ on page 11. If there is apparent damage to the device
or parts are missing from the delivery scope, please contact the
OSRAM support service.
4.3 Maintenance and Repair
Only external cleaning might be necessary. This cleaning may only
be carried out by skilled personnel. To clean the device,
disconnect it from the line power supply. Disconnect all devices
connected to the server. Do not use any cleaning agents
containing solvents (e.g. acetone, alcohol, or thinner) or abrasives.
The housing surface can be cleaned with a moist, lint-free cloth.
Ensure that no water penetrates into the housing. Otherwise, this
could damage the electronics.
!
Before dismounting, appropriate measures must be
taken to protect the respective components against
damage caused by electrostatic discharge (ESD
protection).
!
Do not try to repair the device. Return it to your
OSRAM distributor for replacement or repair.

16
General Remarks
In case of returning the LCE2‑mx
When returning the LCE2-mx for any reason, e.g. for exchange, be
sure to watch the following note:
Always care for proper backup of all user data like shows, images
and media files. Data backup is responsibility of the user, OSRAM
cannot guarantee that user data are kept.
4.4 Support
In case of technical problems or questions regarding installation
and repair please contact:
OSRAM GmbH
Sales Operations
Ursulaplatz 1
50668 Cologne, Germany
+49 221 998830-0
suppor[email protected]
4.5 Warranty Regulations
Depending on the product, guaranty regulations are of different
duration. The warranty time is usually noted in the quote and in the
order confirmation. See “Services” “OSRAM Guarantees” at
www.osram.com for details. Legal warranty regulations apply in
any case.
4.6 Disposal
The proper disposal of packing materials and of the device is the
responsibility of the respective user and for his account; in all
other matters, the retrieval obligation for packing materials and the
device is subject to the statutory regulations.

17
Installation
5 Installation
5.1 Mounting
Place the device on a stable surface.
You can mount the LCE2-mx in racks as well as on walls or on DIN
rails. As delivered, the LCE2-mx is configured for wall mounting.
Use the mounting holes to fasten the LCE2-mx at a secure and
well ventilated place. Place the cooling fins in a vertical orientation.
Ensure proper strain relief for the connected cables.
The hardware for other mounting methods such as on DIN rail can
be additionally purchased. If mounting the LCE2-mx in a rack,
ensure that the server rack is sufficiently ventilated.
5.2 Power Supply
The device should only be connected to a 24 V DC power supply
which satisfies the requirements of safe extra low voltage (SELV).
Use the special terminal plug supplied to connect the supply
voltage. The permitted cable cross-section for the 24 V DC
connection is 1.5 sqmm (AWG 16). Make sure that the terminal
plug is fastened to the LCE2-mx by the lateral screws.
Batteries and technical appliances must not be
disposed of with domestic waste, but should be
handed in at the appropriate collection and disposal
points.

18
Conguration
6 Configuration
The LCE2-mx runs on Microsoft® Windows 10™ as operating
system. It enables you to run lighting control applications as
e:cue’s SYMPHOLIGHT and e:cue’s Lighting Application Suite
(LAS) on the LCE2-mx. When first powering the LCE2-mx, a setup
of the server is required. Set the network properties for the
LCE2-mx and the lighting control applications afterwards.
6.1 LCE2-mx Operation
Connect a display and input devices (keyboard, mouse) to the
LCE2-mx. Display and input devices are always necessary when
accessing any application or settings on the LCE2-mx. Connect
with the power supply and switch on the LCE2-mx with the power
button.
You can hot swap all devices to the LCE2-mx.
!
When adding or removing devices to or from the
system, ensure that the power cables for the devices
are unplugged before the signal cables are
connected.
i
Do not switch off the server with the main switch or
by removing the power supply, but use the Windows
shutdown function to prevent loss of data.

19
Conguration
6.2 Setup
Boot the LCE2-mx by pressing the On/ Off button. Windows starts
its usual setup. Follow the instructions. You can change the
keyboard layout to your needs and also set your time zone which
matters for the lighting show execution.
Windows is set to automatic login. For other cases, these are the
login credentials:
The default user name is: ecue
The default password is: ecue2018!
The LCE2-mx has a second, backup user account prepared for
safety or support reasons. Keep the account and do not change its
settings: ecueBackup (user name), ecueBackup2018! (password).
Especially in case of a forgotten password for the first account,
accessing the user configurations through the backup account
resolves the issue.
Recommendation: Use the default power plan “ecue”. Do not use a
power manager modus which includes “sleep“ since the LAS does
not prevent a system shutdown. As per default, the high
performance power management plan does not allow sleep
modus.
6.3 Network Settings LCE2-mx
Additionally to the network connection to the Internet, the
LCE2-mx is equipped with a second network adapter. This enables
the integration of the LCE2-mx into the network of the lighting
i
Provide an Internet connection for the LCE2-mx on
setup. If necessary, with a running DHCP server to
have an IP address assigned. Update Windows,
SYMPHOLIGHT and the LAS. Enable and execute
updates whenever available.

20
Conguration
installation. Configure the network properties for the LCE2-mx as
in every Windows OS, according to your network requirements:
6.4 Network Settings SYMPHOLIGHT
The e:cue SYMPHOLIGHT application is pre-installed on the
LCE2-mx. SYMPHOLIGHT is a software application to design, test,
and program medium to very complex lighting designs. Developed
with superior usability in mind, e:cue SYMPHOLIGHT is a simple
yet powerful lighting control software with an intuitive graphic user
interface, based on advanced timeline programming. For
SYMPHOLIGHT to communicate with the network devices in the
installation, SYMPHOLIGHT has to be adjusted to the same
network as all the other network components. The next steps
describe how to set the network address in SYMPHOLIGHT. For
further information about SYMPHOLIGHT, please refer to the
SYMPHOLIGHT User Manual.
—Start the SYMPHOLIGHT application.
i
Use the preferred dedicated local network range
192.168.123.xxx with one system-internal network
adapter.
Table of contents
Languages:
Popular Server manuals by other brands

Hitachi
Hitachi HA820 G3 Series user guide

Sun Bandit
Sun Bandit SPARC Enterprise M4000 Getting started guide

Supermicro
Supermicro SuperServer 1019GP-TT user manual

Fujitsu
Fujitsu Primergy CX270 S2 Upgrade and maintenance manual

Inspur
Inspur Tiansuo TS860 user manual

IBM
IBM 7380E1U Installation and user guide