PA Strong PAB-9120 Guide

1
PUBLIC ADDRESS
SERIES 8000 AMPLIFIER
Installation and User Instructions
PowerAmplifier
●PAB-9120
●PAB-9240
●PAB-9360

2
IMPORTANT
Before installing or operating this product, please always read this manual carefully.
WARNING:
To prevent the risk of fire or electric shock, never expose this product to rain or humidity.
Table of contents
Important safeguards-------------------------------------------------------------------------------------2
Table of contents------------------------------------------------------------------------------------------2
1. Introduction------------------------------------------------------------------------------------------------3
2. Features----------------------------------------------------------------------------------------------------3
3. Front Panel------------------------------------------------------------------------------------------------3
4. Rear Panel-------------------------------------------------------------------------------------------------4
5. Installation-------------------------------------------------------------------------------------------------5
6. Specification----------------------------------------------------------------------------------------------8
Introduction
PAB-9120/9240/9360 is a power amplifier series. The output power are 120W, 240W and 360W for wide range purpose.
Once there is defective, it will be indicated at the front panel.
Dry contact will short to trigger external system when the fault is detected in the amplifier or installation system.
0-8Ω-70V-100V different level output for different speaker system.
24V battery back up power source will operate when the AC power source is off.
Features
zIt has 20 KHz built-in detecting circuit, which is used to detect whether the unit works normally or not.
zIt has 100V input terminal. It can apply to long distance extension network installation.
zIt has balanced XLR input terminal and unbalanced RCA input terminal.
zThe unit could be triggered by remote control terminal.
zIt has 0-8Ω-70V-100V output terminal for different output voltage and impedance.

3
Front Panel:
1. Power LED
When it is power ON, the blue LED will light up.
2. Fault LED
Set the built-in 20 KHz detect switch at “ON”.
If there is no 20 KHz signal output, over heat, short circuit, the Fault LED will light up.
Set the built-in 20 KHz detect switch at “OFF” will not detect 20KHz in the system. The Fault LED will not light up.
3. LED VU Meter.
VU meter to indicate output signal level.
Rear Panel
4. AC Line Voltage Selector.
Set the slide switch to select AC line voltage (115V or 230V AC).
Note:
Never set the switch to wrong AC Line voltage, it will cause damage to the unit.
5. Power Switch
Press rocker switch to switch on the unit. Press again to switch off the unit.
6. AC Inlet Socket
To plug in AC power cord.
7. AC Line Fuse Bracket
Insert fuse to the fuse bracket to provide protection for over current.
Note:
Always use fuse with correct current and voltage rating.
8. Chassis Ground
A Chassis Ground should be connected during installation

4
9. DC 24V Input Terminal
Input terminal to connect DC 24V power source
Note:
Never connect to the wrong polarity of DC power source.
10. Output Terminals
Amplifier output terminals with 0-8Ω-70V-100V for different output voltage level and impedances.
11. Dry Contact Control Terminal
Dry contact will close when the unit is damaged or no output.
12. Power Remote ON/OFF Terminal
Remote control the unit to power ON when the unit is under power switch OFF state.
Short Remote Power ON/OFF terminal, the unit will be switched to power “ON”.
If the unit is switched to power “ON” state, this Remote Power ON/OFF terminal can not control the unit.
When the unit is operated by DC source, it can not be controlled by Remote Power terminal.
13. Loop Through RCA Unbalanced Output
RCA terminal for unbalanced input loop through signal to pass the input signal to other amplifiers.
14. Loop through XLR Balanced Output
Loop through XLR balanced output terminal.
15. XLR Balanced Input
XLR socket for balanced input signal.
1 Vrms, balanced, XLR input.
16. RCA Unbalanced Signal Input
RCA unbalanced signal input is in parallel to XLR balanced input.
The signal level is 1V, 10KΩunbalanced.
17. Input Signal Level Trimmer
To adjust the input level of input signal.
18. 0-100V
For 100V signal input.
19. 20KHz ON/OFF Switch
Set it at “ON”, pilot tone detect function is ON.
Set it at “OFF”, the pilot tone detect function will be off.
3. Installation
3.1. Unpack packing box
Open the package box and take out the unit.
Please check the accessories and read manual before operate the unit.

5
3.2. (optional) Install unit in rack.
The PAB-9120/9240/9360 is designed for table top use.
If user wants to use in the rack, please screw on rack mounting bracket .
Please refer to the drawing.
3.3. Set correct AC line in voltage
Refer to the AC line in voltage select switch (4)
Set the slide switch to correct AC line in voltage.
3.4. Plug in AC power cord
Plug the AC power cord to the AC socket.
Before switch on the unit, please confirm all the installation system is properly connected.
4 Connections and settings
4.1. Balanced/unbalanced signal input
There are two types of input:
One is balanced signal, the other is unbalanced.
It is convenient for connecting the signal from external music source or preamplifiers.
Mixing Console

6
4.2. 100V input
100V input can be connected to amplifier’s output. It is suitable for long distance network.
4.3. Adjust input signal level
Turn the input trimmer. (17) to adjust input level.
4.4. Loop through output
The input signal is loop through to output XLR and RCA terminal.
It can be connected to next amplifier.
4.5. 20KHz ON/OFF
20KHz is a pilot tone signal. By the detecting of 20KHz in installation system, we can judge the system is working
properly or not .
Set the switch at “ON”, the built-in 20KHz detecting system will work to judge the operation of the system. If there
is not 20KHz, the fault LED will light up, and dry contact terminal (10) will be activated.
Set the switch at “OFF”, the built-in 20KHz detecting system will not work .
4.6. Power remote control
Switch off the Power Switch, the unit is off.
With external switch closed, the unit can be powered on and operate.

7
4.7. Speaker connection
There is output terminal with 0-8Ω-70V-100V for different purpose and load.
Please pay attention to the total equivalent impedance should not be lower than the rated load impedance.
4.8. DC battery
The DC batteries 24V is a back up power source.
When the AC power source is off, the DC 24V will take over and let the unit to continue to work.
PAB-9120/9240/9360 Power Amplifier Specifications
Model No. PAB-9120 PAB-9240 PAB-9360
Power Source 115/230V AC, 50/60Hz, 24V DC
Rated Output 120W 240W 360W
Amp Type Analog Analog Analog
Power Consumption 360W 720W 1080W
Frequency Response 50 - 20KHZ +1/-3dB
Distortion <1% under rated output power
Input
Balanced LINE IN: 1V,balanced
XLR terminal
Unbalanced LINE IN: 1V, 10 KΩ, unbalanced
RCA terminal
100V Input 100V, balanced input
Output Unbalanced loop through: 1V, unbalanced, RCA Jack output

8
Balanced loop through: 1V, balanced, XLR Jack output
Output: 100V - 70V - 8Ω-0.
S/N Ratio > 85dB
Control Input
Remote Power: Dry Contact terminal
Open Voltage: 24V DC
( when the unit’s power is OFF ), Short circuit to
switch ON the unit.
Dry Contact: Open: during normal operation
Short: when unit is abnormal
Indicator
Output level meter: 5 LED
Power indicator: 1 LED (Blue)
Fault indicator: 1 LED (Amber)
Control Sen. VR to adjust input signal level
20KHz Slide Switch: ON/OFF 20KHz pilot
tone
Operating Temperature: -10~45℃
Dimension (H×W×D): 88×430×300 mm 88×430×300 mm 88×430×385 mm
Weight: Approx 10.0kg Approx 13.0kg Approx 20.0kg
Mounting ( optional ) Table Top or 19" Rack
Mountable
Table Top or 19" Rack
Mountable
Table Top or 19" Rack
Mountable
* 0dB = 1V
* -20dB = 0.1V
* -60dB = 1mV
zLoad:
PAB-9120: 83Ω
PAB-9240: 42Ω
PAB-9360: 28Ω
Note:
The specification and design are subject to change without notice for improvement.
Once fault protection LED light up, the unit will stop operation until faulty issue is solved.
This manual suits for next models
2
Table of contents
Other PA Strong Amplifier manuals
Popular Amplifier manuals by other brands

Balanced Audio Technology
Balanced Audio Technology VK-150SE owner's manual

Pioneer
Pioneer GM-6300F/XU/UC Service manual

Egnater
Egnater Rebel-30 Head owner's manual

RAAL-requisite
RAAL-requisite PDA-1a user manual

Brooke
Brooke XPRO-1800 instruction manual

QUAD
QUAD Vacuum Tuber Amplifier Systems II-FORTY Brochure & specs