ACM12-EI06 06/2019 PARADOX.COM
ACM12
Installation Manual V4.69 and higher
Supports EVOHD / EVO192 V4.5 and higher
Description
Thank you for choosing the ACM12 for your access control. The ACM12 is designed to be used with the Paradox EVO system.
It allows you to manage access of one door, via card, pin or both, provide forced door and door left open detection, and arm / disarm functions.
The ACM12 supports full Off-Line functionality, which stores the entire database in memory when the panel connection is lost and enables full
synchronization upon restore. It supports one IN reader and one OUT reader if using 4-wire Paradox readers, or one IN reader only if using the
7-wire 26-bit Wiegand reader. The ACM12 also supports a REX, a door contact that can be an alarm zone, and a door locking device.
With accelerated response of up to 999 users, simple and minimal programing, as well as easy installation, the ACM12 is designed to provide
you with a reliable and professional access solution.
Compatibility
ACM12 V4.5 and higher is compatible only with panels EVOHD V4.5 and higher and EVO192 V4.5 and higher.
Upgrade Note
When upgrading to the latest version, it is advisable to upgrade the panel first, and then upgrade the ACM12 module.
Off-Line Feature
The ACM12 V4.5 and higher fully supports Off-Line functionality. In the case of panel connection loss, the ACM12 will switch to Off-Line mode
and will fully function with user access level and schedules; arm / disarm user permissions will be overridden. While resuming communications
with the panel, all programming changes will be updated. In Off-Line mode, events are kept locally in the module and can be uploaded manually
for each ACM12 when communication is restored.
Installation (Figure 1)
Connect the ACM12 as per the drawing below. When powering up, all ACM12 modules will synchronize with the panel and upload all user and
schedule data. Typically, 100 users and 10 schedules will take about 50 seconds to upload. This will also take place upon resuming connection
with the panel. Synchronization is indicated by RX/TX LEDs flashing together at 4 Hz. If an ACM12 V4.5 detects a connection to a different EVO
panel, data will be erased and the new panel data will be synchronized.
POWER: The ACM12 should be powered with a 16 Vac 20Va. Battery should be connected.
Figure 1
Unlock Device Diode: When connecting a locking device, it is recommended to connect diode 1N4007 as per Figure 1, to keep the relay
contacts reliability.
Firmware Upgrade: Should you need to upgrade the ACM12 firmware, connect the CV4USB A+ to Green and B- to Yellow, and power Red
and Black.
Turning Auxiliary Power ON / OFF (V4.52 and above)
Press and hold the AUX ON / OFF switch for 7 seconds. This toggles the auxiliary power ON or OFF.
IN / OUT Reader Assignment (V4.52 and above)
The reader that is detected first will be considered the IN reader, by default. The reader that is detected second will be considered the OUT
reader.
Changing the Default Reader Assignment (V4.52 and above)
1. Press and hold the AUX ON / OFF switch for 3 seconds. The ERROR, TX and RX LEDs flash for 2-3 seconds.
2. Press any key or present an access card to the reader you want to designate as the IN reader. Automatically, the other reader will be des-
ignated as the OUT reader.
ACM12 Connection to PS45
Connect the ACM12’s AC and ground to the PS45’s Aux +and - connectors. You can power up to three ACM12 modules using the PS45 Power
Supply instead of using separate transformers for each ACM12. Connect each ACM to the appropriate output, as shown below.
AC
AUX BATT
AUX
STAT
RX
TX
BATT
RED BLK
AUX
AC
EVO
BUS
+RED
TRIG BLK GRN YEL
GRN YEL
READER
-PGM
N.O.N.C.COM TMP CT REX DO D1
~~
MANUAL
DOOR
TRIGER
16 VAC
12 VDC
600 mA
*
EOL
DOOR
CONTACT
REX
READER
IN
READER
OUT
*
EOL FOLLOWS
PANEL DEFINITION
AUX ON / OFF SWITCH
FUSE 5A / 28 VDC
EVO
1 2 3
4 5 6
7 8 9
X 0 
1 2 3
4 5 6
7 8 9
X 0 
R1 R2
+
-
BUS SUPPORTS
IN AND OUT READERS
DOOR LOCK
5A / 28 V
MAX
*
1N4007
DIODE
TAMPER
TO
AUX
+
BEEP RED GREEN
OPTIONAL 7-WIRE
26-BIT WIEGAND
CARD READERS
NOTE: IF CONNECTING
TWO READERS TO THE
SAME ACM12 MODULE
ENSURE READERS ARE
THE SAME VERSION
Connection Description Connection Description
TRIG Shorting to ground will activate the unlock relay. TMP
Tamper switch follow panel definition Section [3034]
ACM12 programming section [003] option1 to
enable.
COM/NC/NO Unlocking relay, max 5A / 28 VDC
AC - 16V 20 VAC EVO BUS Connect to EVO bus.
Additional Aux (-) CT
Zone for door contact. Can be system zone Section
[0400], EOL will follow panel global EOL panel
section 3033 bit 7.
AUX Use to power the Reader, REX, and other devices.
Max output 600mA, fuseless shutdown. REX Request for exit detector connection, it is connected
without EOL.
PGM 50mA output follow. Some predefined conditions,
see programming Section [011]. D0 Connect to Green wire of the Reader.
CT Door contact is used to monitor door condition and
to identify door left open and forced door status. D1 Connect to Yellow wire of Reader.
ACM12-EI06 06/2019 PARADOX.COM
Programming via BabyWare or Keypad
Installer + Section [4003] + Serial Number of the ACM12.
* = Default
* Follow Panel User Schedules.
LED Feedback
* RX / TX will flash together at a frequency of 4Hz when synchronization takes place.
Error Display
Technical Specifications
Section [001] General Options
Option OFF ON
[1] Tamper Input Disabled* Enabled
[2] Battery Charging Current 350mA* 850mA
[3] AC monitoring Disabled Enabled*
[4] & [5]
[4] [5]
Card only OFF* OFF*
Card or PIN ON OFF
Arm and Access: Card or PIN
Disarm: Card and PIN OFF ON
Card and PIN always ON ON
[6] Unlock door on Fire Alarm Disabled Enabled*
[7] Door forced open Alarm Disabled* Enabled
[8] Card activates door unlocked schedule
(V4.52 and above) Disabled Enabled*
Section Data Description Default
[002] __/__/__ (Seconds) Door Unlocked Period 005
[003] __/__/__ (Seconds) Door Unlocked Period Extension (handicap use) 015
[004] __/__/__ (Seconds) Door Left Open warning delay 060
[005] __/__/__ (Seconds) Door Left Open Alarm delay from warning 060
[006] __/__/__ (Minutes) Safe Unlock delay 00
*[007] __/__/__ (01 - 32) 1st Unlock Door Schedule 00
*[008] __/__/__ (01 - 32) 2nd Unlock Door Schedule 00
*[009] __/__/__ (01 - 32) 3rd Unlock Door Schedule 00
*[010] __/__/__ (01 - 32) 4th Unlock Door Schedule 00
Section Data Description Default
[011] __/__ PGM Activation 00
00 : Arm
01 : Follow Door Unlock Schedule
02 : Follow Access Granted (will be activated for the unlock period)
03 : Follow Door Forced State
04 : Follow Door Left Open Warning / Alarm
05 : Utility Key 1
06 : Utility Key 2
07 : Utility Key 3
08 : Utility Key 4
09 : Utility Key 5
10 : Utility Key 6
11 : Utility Key 7
12 : Utility Key 8
13 – 99 : Future Use
Section [012]
Option OFF ON
[1] Partition 1 Disabled Enabled*
[2] Partition 2 Disabled* Enabled
[3] Partition 3 Disabled* Enabled
[4] Partition 4 Disabled* Enabled
[5] Partition 5 Disabled* Enabled
[6] Partition 6 Disabled* Enabled
[7] Partition 7 Disabled* Enabled
[8] Partition 8 Disabled* Enabled
Section [013]
Option OFF ON
[1] Re-lock option On door opening On door closure
[2] On access granted / utility key event PGM follow lock delay PGM toggle state
[3] Unlock schedule override on access granted Disabled Card locks door
[4] - [8] For future use - -
AC On (green) when module has AC power.
BATT On (green) when charging and during battery tests. Battery test every one minute.
AUX On (Yellow) when auxiliary output is active.
STAT On or flash (Red) when an error occurs. Refer to Error Display table below.
RX Flashes (Green) when receiving information from the panel.
TX Flashes (Green) when transmitting information to the panel.
STAT
(Red)
RX
(Green)
TX
(Green)
Condition
ON OFF OFF EVO bus is shorted / No clock / No data (offline)
ON OFF ON Wrong data / Invalid EVO address, too many modules or incompatible panel version
ON ON ON EVO bus YEL and GRN reversed
FLASH ---- ---- EVO bus voltage is low (less than 9V)
User Capacity 999
Door Unlock Schedules 4 (total of 8 periods)
User Schedules Capacity 32
User Security Levels 15
Power 16 Vac, 20 VA
Auxiliary Output 12 Vdc, 600 mA, 1A fuseless shutdown
Battery 12 Vdc, Gel Cell. Connection protected with 5A fuse
Door Unlock Form C relay rated at 5A / 28 Vdc
PGM Output 50 mA predefined definitions
Device Connections Two Paradox 4-wire readers or one 7-wire 26-bit Wiegand reader, door contact,
REX device, tamper
Manual Unlock Negative trigger input
Control Panel Compatibility EVOHD Control Panel V4.5 and above
EVO192 Control Panel V4.5 and above
Metal Box (optional) Minimum 20 x 25.5 x 7.6 cm
(8 x 10 x 3 in.) metal box
Dimensions 14 x 9.2 x 2.5 cm (5.5 x 3.6 x 1 in.)
Warranty
Please refer to the Limited Warranty Statement found on the website www.paradox.com or contact your local distributor.
© 2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice.
Patents
One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and
other pending patents may apply. Canadian and international patents may also apply.

Popular Controllers manuals by other brands

Micatrone MRP-2000 Operating and installation guide

Micatrone

Micatrone MRP-2000 Operating and installation guide

Newport Spectra-Physics ST-200 user manual

Newport

Newport Spectra-Physics ST-200 user manual

Timken StatusCheck quick start guide

Timken

Timken StatusCheck quick start guide

AUMA SGExC 05.1 Operation instructions

AUMA

AUMA SGExC 05.1 Operation instructions

Eaton Cutler-Hammer S801TR Quick setup guide

Eaton

Eaton Cutler-Hammer S801TR Quick setup guide

Arlight YM-801RA manual

Arlight

Arlight YM-801RA manual

Velleman VMA409 user manual

Velleman

Velleman VMA409 user manual

ABB ACS150 series user manual

ABB

ABB ACS150 series user manual

Mold-Masters TempMaster MT quick guide

Mold-Masters

Mold-Masters TempMaster MT quick guide

Bosch Rexroth IndraDrive HMD01 operating instructions

Bosch

Bosch Rexroth IndraDrive HMD01 operating instructions

Hathorn H12+ Operator's manual

Hathorn

Hathorn H12+ Operator's manual

HomeRun HomeManager ST manual

HomeRun

HomeRun HomeManager ST manual

EMKO ESM-9995 manual

EMKO

EMKO ESM-9995 manual

TouchWand Wanderfull Hub user manual

TouchWand

TouchWand Wanderfull Hub user manual

Delta Tau PMAC 1.5 Lite Hardware reference manual

Delta Tau

Delta Tau PMAC 1.5 Lite Hardware reference manual

Pilz PNOZ m EF SafetyNET operating manual

Pilz

Pilz PNOZ m EF SafetyNET operating manual

Emerson FPCSK instruction manual

Emerson

Emerson FPCSK instruction manual

Sun Yeh Electrical OME Series Operation manual

Sun Yeh Electrical

Sun Yeh Electrical OME Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.