
HV8D - page 2
Wiring
Related Topics Specifications
Installation / Wiring (see Imperial System Guide)
• DIN Rail Enclosure
• System Diagrams and Wiring Tips
• Wire Gauge Selection
Features
• Shutter Calibration (see page 3)
• Bi-directional Locate Feature (see page 4)
• Remote Firmware Upgrade (see page 4)
Applications (see Imperial System Guide)
•Shutters
• Light Control
• Sprinklers
•Macros
BabyWare (see Imperial System Guide)
• BabyWare
Operating
voltage
120Vac to 230Vac (nominal)
Frequency 50 to 60Hz
Maximum load 10A for incandescent lamps, fluorescent lamps,
electronic step-down converters (halogen), and
iron-core transformers (extra low-voltage
incandescent lamps).
8A for 0.5hp motors.
Multibus 900m (3,000ft)
Current
Consumption
min. 40mA
max. 500mA
No. of inputs 6 (4 emergency stop and 2 global up/down)
Dimensions DIN9: 16cm X 10cm X 6cm (6.3” X 4” X 2.5”)
Operating
Temperature
-10ºC to 50ºC
14ºF to 122ºF
1Relay Mode
If, in BabyWare, the output is set to
Light, Sprinkler, or Custom, it will
function as a standard relay output.
See "Relay vs. Shutter Mode” on
page 3.
2Shutter Mode
If, in BabyWare, the output is set to
Shutter, the related outputs (Up/
Down) will be paired for shutter
operation. See "Relay vs. Shutter
Mode” on page 3.
3Local Bus (Future Use)
Imperial Dimmer Wall Switches that
are connected to the local bus are
independent from the rest of the
system and can control the shutter
outputs. This ensures continued
operation of the outputs should the
Multibus stop for any reason. This
feature also provides the option to add
shutter control without the need of the
Imperial system. If in relay mode, only
the odd numbered outputs can be
controlled (e.g. 1, 3, 5, 7).
4Global Up/Down
By connecting a 2-way momentary
switch, all connected shutter motors
can be activated together.
5Emergency Stop
It includes an emergency stop input
per shutter motor to connect a device,
such as an IR beam, to stop the motor
when motion is detected. The motor
will also stop when the dial on the
dimmer wall switch is pushed.
AC power line
Shutter
Motor
N
Up
Down
YEL
GRN
BLK
RED
YEL
GRN
BLK
RED
Global
Up / Down
Emergency
Stop
Breaker
Breaker
LNLN
MODULE BREAKER NO: HV8D
BUS INPUT LOCAL BUS
1 2
3
5
4
Imperial Multibus
GRN3
Controls
RLY5/RLY6
GRN1
Controls
RLY1
By default, using the Global
button on any dimmer wall switch
connected tot he Local Bus will
control all outputs that are in
Shutter Mode
WARNING:
It is highly recommended to power the module using an
external source (e.g. PS100 or PS27D) and NOT from the
Multibus to avoid flickering of the output in case of a loss
of bus power. Flickering might cause damage to electrical
appliances connected to the outputs.
Local bus
(future use)