manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Paremtech
  6. •
  7. Measuring Instrument
  8. •
  9. Paremtech PT Level User manual

Paremtech PT Level User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

English Instructions
Let’s get started!
• PTLevel Transmitter
• PTLevel Receiver
• Power Supply
• 13’ of attached tubing
• Instructions
• Pressure chamber
• 4 AA Batteries
Contents
Watch Installation YouTube videos
Search for the ParemTech channel
PTDevices.com
Servers
110v Power
PTLevel
Receiver
Home Router
WiFi
Long Range
Wireless
Connection
5/32”
Black
Tubing
Pressure
Chamber
Cistern,
Well,
Tank, Etc..
Troubleshooting Maintenance
Calibration
Setup Overview
Can’t connect to WiFi
• Check the strength of the WiFi signal. Try moving the
receiver closer to your WiFi router.
• Ensure that the password you are entering is correct
during the setup. You can check by trying the password
with another device. Note: WiFi passwords are case
sensitive.
Level is not reading accurately
• Pull the weight out of the liquid volume, let it drain and
replace it back in the liquid. This resets the air pressure.
• Check for any possible air leaks along the tubing and
connections.
• Check for any water in the small back tube by applying
a slight vacuum to it.
Transmitter status conditions
• Three blinks slowly after pressing the connect button.
Successful connection
• Two quick flashes after pressing the connect button.
Cannot find/connect to the receiver. See below.
Receiver and Transmitter not connecting
• Check the distance and the objects in between. Try
moving the transmitter closer to see if a connection can
be established.
• Transmitter and receiver may not be linked for some
reason. Please contact us about this.
We recommend that once a season you remove the
pressure chamber from the liquid volume, let it drain,
then replace it into the liquid again. This resets the air
pocket and will keep the reading as accurate as
possible. Press the “connect” button on the transmit-
ter to update the online level. You should also
re-calibrate.
1. Measure the amount of liquid in the tank.
2. Divide that measurement by the full empty depth
of the tank.
Ie: 72” of water / 144” tank height = 0.5
3. Multiply the above result with 100 to get the
current percentage.
Ie: 0.5 * 100 = 50%
4. Enter the result from step 3 into the calibration
input online.
Make sure that your device is functioning and
connected online first.
Battery Replacement
Simply remove the four screws on the PTLevel
transmitter lid. Pull off the lid and the batteries will be
visible.
1Connect the Home Receiver
Placement
Place the receiver somewhere inside where there is a
power outlet and WiFi signal.
Use a phone or
tablet or PC to
connect to
PTLevel WiFi
Open a browser
and enter in
192.168.4.1 into
the address bar
Select the
strongest WiFi
signal that has
internet
Enter the
password for the
selected WiFi
Wait for the
PTLevel to
connect
When you see the
screen below,
you’re done! If not,
try again or see
troubleshooting.
2Setup the Transmitter
Mount the transmitter onto the
tank you would like to
measure/monitor. Use screws or
other means to mount it properly.
Pic 1 is an example for a typical
cistern.
Mounting the transmitter
PTLevel
transmitter
Drill hole for
tubing
Cistern
WiFi Connection Setup
Pic 1
Setup the pressure chamber
Below is an illustration on how to connect the pressure
chamber using the provided clamp, bushing, and tube.
After the PTLevel is mounted, run the black tube through
any necessary holes before proceeding to the next step.
Depending on the device you are using, find where you
can see the list of available WiFi signals. If you need
more help with this, see our YouTube videos.
Lower the pressure chamber
Once the black tubing is fully connected and sealed
tight, lower the pressure chamber into the liquid volume
and allow it to lower to the bottom slowly.
See the Overview on the other side.
Note: Do not drop the chamber in an empty tank or it
could break.
Note: You can cut the black tube shorter if you need, just
pull it out of the liquid before you disconnect any of the
tubing.
Check the wireless connection
Press the connect button on the side of the PTLevel
transmitter. If the status LED blinks three times slowly,
you are connected! See the troubleshooting on the other
side if the LED does not blink three times slowly.
3Setup Online
Create an account
Visit www.ptdevices.com and select “Sign Up” if you
don’t already have an account. Fill out the required
inputs or click on a social login option for a simpler
process.
Final setup!
If everything setup properly, you should see a level
reading online. Press the connect button on the
transmitter for a more recent reading.
After you have selected the “Add my device” button, you
should see a “Waiting for device to connect” screen. If
the PTLevel receiver is all setup properly, the waiting
screen should disappear within a minute. If it does not,
click on the “Remove this” and try adding it again. If it
still does not work, try connecting the WiFi again.
Click on the “Please Setup” button near the level
reading. Enter in the full depth of the tank and configure
anything else.
Congratulations!
You should be all setup. See the calibration section on
the other side to do your first calibration.
Add your device
Once in your account, select “Add PTLevel” from the
menu or “Connect It” from the dashboard. On the next
screen, add the following ID of the PTLevel.
Note: Make sure all
tubing connections
are setup and
sealed properly or
the PTLevel will not
read accurately.