PDR PDM750F-11 User manual

Model
Thank you for purchasing thePDR panel display wall mount.
To ensure the correct usage, please read and follow the instructions
manual thoroughly. Please store the instructions in a safe place for future reference.
To ensure customer safety, be sure to decide the installation location so that the strength is sufficient to withstand the weight of both the panel
display and the wall mount.
Always use at least two persons for all installations.
Fully tighten all of the mounting screws as specified in the installation instructions.
Parts Configuration Chart Features
Mounting points for panel display models
Special techniques are necessary for installation of the panel display mount.
Do not attempt to perform this work by yourself.
Request an installation specialist to install this unit.
Manufacturer assumes absolutely no responsibility for injuries and damages that may occur due to improper installation and handling.
Please remember that if you remove the panel display from the wall later, you will find the screw holes and anchor bolts for the
mounting unit left on the wall. Also note that long use of the panel display may discolor the wall around it due to its heat and
airflow.
Wall mount bracket…1 pc
A
B
D
E
5 mm x 16 mm Phillip screws…4 pcs
5/16" x 2 1/2” Lag bolts …6 pcs
Display bracket .... 2 pcs
G
F
C
6 mm x 16 mm Phillip screws…4 pcs
5/16" Flat washers…6 pcs
H
J
K
1
Square multi-mount washers...4 pcs
10-1.25mm x 25mm hex head bolt...4 pcs
I
Panel Display mounting slots
Fig 1
Mounts by
A division of David Engineering & Mfg. Inc.
PDM750F-11 PANEL DISPLAY MOUNT
Locking bar... 2 pc
Top
Bottom
8 mm x 16 mm Phillip screws...4 pcs
10-1.5 mm x 25 mm Phillip screws...4 pcs
?Low profile 1 5/8”
?Easy installation
?16”/24”/36” wall stud mounting points
?Flat or 5° tilt (no tools required)
?Lateral movement from center for better viewing position
All PDR mounts and adapters carry a lifetime warranty against defects in material and workmanship.
Check the PDR website for details @ www.PDRmounts.com. We are not liable for improper installation that results in damage
to mounts, adapters or presentation equipment.

the strength of the wood studs is not sufficient, add reinforcement.
Always confirm the center of the stud is used for the installation.
Avoid installing in locations where the temperature and humidity are excessively high, and where contact with any
not install in locations where there are excessive amounts of dust,
Do not block the ventilation holes. Leave sufficient clearance in regard to the surroundings to avoid blocking the ventilation..
The internal temperature could elevate and possibly result in fire. Install the panel (4") or more away from surroundings.
sloped surfaces. Also, do not install facing upward. The internal temperature could
elevate and possibly result in fire. Injury or damage could also result from falling.
Do not install in locations where there is excessive vibration or impact. Injury and damage could result from the panel display
light. Strong light could result in eye fatigue during usage.
Use the specified bolts and screws in the specified places and tighten firmly. Failure to do this could cause injury if the panel
could result with injury due to the panel display falling.
Always use at least two people to perform the installation work. Injury could result from dropping heavy objects.
be installed must be capable of long-term support of the total load of
so be taken to ensure sufficient strength to
bration and other external forces.
anel display to fall and cause injury.
anel display + wall mount)
C a u t i o n : I n s t a l l a t i o n o f u n i t i s t o b e c a r r i e d o u t b y q u a l i f i e d t e c h n i c i a n s o n l y . I n s t a l l i n a n a p p r o p r i a t e
l o c a t i o n b y c h e c k i n g t h e w a l l s t r u c t u r e a n d d u r a b i l i t y f o r s a f e t y a n d a c c i d e n t p r e v e n t i o n .
INSTALLATION LOCATION
INSTALLATION ON A WOODEN WALL
Always install so that the load is supported by a wood stud. If
Do not install on decorative posts or plaster board.
water is possible. These can result in fire or electric shock.
Do not install close to an air conditioner intake or outlet. Do
oily smoke or tobacco smoke. Fire could result.
.
Install only on a vertical surface. Avoid
falling.
Do not install where there is direct sunlight or other strong
display falls.
Do not alter any of the parts. Do not use broken parts. This
The wall where the wall mount is to
the panel display and wall mount. Measures should al
withstand the force of earthquakes, vi
Note: Incorrect installation can cause the p
Total load of the panel (p
2
CAUTION
WARNING
WARNING
Rev 021209
MAXIMUM WEIGHT - 400 lbs. (181 Kg.)
Make sure that both hooks from each pivot bracket engage with the wall bracket. Failure to do so could cause the panel display
to fall.

1. FASTEN MOUNTING PLATE TO WALL
Fig 2
2. SECURE THE DISPLAY BRACKETS TO THE MONITOR
NOTE: Do not over tighten the bracket mounting screws as damage to the display internal mounting threads could occur.
The bracket must be secured to the wall studs capable of holding at least (4) times the weight of the unit. The wall bracket should be mounted at the same horizontal center line
as the display center line ( viewing horizontal center line). Using the six lag bolts (E) and washers supplied (D) Level and secure the mounting plate to the center of
the wall studs. Pre drill 3/16” (5mm) hole for lag bolts
FLOOR LINE
VIEWING
HORIZONTAL
CENTER LINE
Fig 3
3
Mounting hardware F,G,H,I,K
Square Multi-mount washer ( J )
Panel display bottom edge
Display bracket ( A )
24”
16”
32”
WOOD STUDS
(std construction 2 x 4 studs/1/2” wallboard)
Fig 2
Lay the display panel face down on a protected surface.
Position the left and the right hand brackets (A) with the slots facing towards the top. See Fig.3. Note Bottom Edge!
Using the proper screws ( F,G,H,or I) and square multi-mount washers (J) supplied, position the brackets equal
distance from top to bottom and tighten hardware.

3. MOUNT THE DISPLAY TO THE WALL MOUNT BRACKET
Fig 4 Fig 5
4. Adjust lateral movement
Lateral Movement:
Fig 6
4
Fig 7
Once the installation of the display on the wall is complete, you can still move the display left to right to optimize the final viewing position by gently sliding the unit on the wall
bracket. The adjustment distance will vary depending on the display model being installed.
5°
Slot 1 position for 5 deg tilt Slot 2 position for no tilt
Locking bar
Lift the display with the brackets attached onto the wall plate. See Fig4
Position the top in either slot 1for 5deg tilt or slot 2for flat mounting See Fig 5 and Fig 6
Insert the locking bar, (C) as shown in Fig 5 with the locking holes facing up to match the holes in the wall mount bracket (B) . Make sure the display brackets
engage the rails on the wall mount bracket (B) See Fig 5.
Secure with a padlock (not supplied), if required, thru holes in the locking bar (C) and wall mount bracket (B)Fig 5
Table of contents
Other PDR Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Ropox
Ropox 4Single Series User manual and installation instructions

Yamaha
Yamaha SPM-K1 - Mounting Kit For Speaker installation manual

Ergotron
Ergotron Neo-Flex OM10245 instruction manual

Exelium
Exelium X-FLAT installation instructions

Beyerdynamic
Beyerdynamic UNITE CR quick start guide

Royal Catering
Royal Catering RCMR-800P5 user manual

Vivo
Vivo STAND-V032 instruction manual

CHIEF
CHIEF Large Flat Panel Dual Arm Wall Mount PNR installation instructions

Techly
Techly ICA-TR12 user manual

PEERLESS
PEERLESS Mobile Videowall Trolley PDVWM 2x2 46 55 L Installation and assembly

Costway
Costway HW65211 user manual

CHIEF
CHIEF MSR Series installation instructions