ISSUED: 04-08-08 SHEET #: 055-9094-2 06-06-08
Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.
6 of 16
CORRECT
wallplate concrete
plaster/
drywall
Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifications.
It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breakingout the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Makesure that the supporting surface will safely support the combined load of the equipment and all attached hard-
wareand components.
WARNING
CUTAWAYVIEW
• Tighten screws so that wall mount is firmly attached,
butdo not overtighten.Overtightening candamage
screws,greatly reducing their holdingpower.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
SOLID
CONCRETE
CINDERBLOCK
• Always attach concrete anchors directly to load-
bearingconcrete.
• Neverattach concrete anchorsto concrete covered
withplaster,drywall, or other finishing material. If
mountingto concrete surfaces coveredwitha finishing
surfaceis unavoidable, the finishing surfacemust be
counterboredas shown below.Be sureconcrete
anchorsdo not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
2concrete
surface
1
3
2
U
Drill holes and insert anchors (U).
Place wall mount assembly (A)over anchors (U) and
secure with screws (Q).
Tighten all fasteners.
A
U
Q
U
CARRIAGE
AQ
fig. 2.3
Use wall mount assembly (A) as a template to mark
mouting holes. Drill six 5/32" (4 mm) dia. holes to a
minimum depth of 2.5" (65 mm). Insert six anchors (U) in
holes flush with wall as shown (right). Fasten two #14 x
2.5" wood screws (Q) into top anchors (U) leaving a .25" of
exposed thread for each screw (Q) as shown. Hook wall
mount assembly (A) onto #14 x 2.5" wood screws (Q) as
shown in fig. 2.3. Fasten four #14 x 2.5" wood screws (Q)
into wall mount assembly (A) as shown. Make sure that the
wall mount assembly (A) is level, tighten all six #14 x 2.5"
woodscrews (Q).
Skip to step 3.
INCORRECT
wallplate
plaster/
drywall
concrete
.25"
Q