Plaston Air-O-Swiss AOS 7135 User manual

PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
AOS 7135


3
Instructions for use (5 – 20)
en
Instructions d’utilisation (21 – 36) a
fr
Instrucciones para el uso (37 – 51) a
es

4

5
en
Instructions for use

6
en
Important safety instructions
• Priortousingtheappliance,readthroughthe
instructionsforcompleteuseandretaininasafeplace
forlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithin
thespecifiedtechnicaldata.Improperusecanbe
hazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrent(AC)with
voltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociated
withtheusageofelectricalappliances.Forthisreason,
alwayssupervisechildrenwhentheyarenearthe
humidifier(image1).
• Neverusetheapplianceifthereisanydamagetothe
applianceorcable(2),aftermalfunction,afterthe
appliancehasbeendropped(3)ordamagedinany
otherway.
• Repairsofelectricalappliancesareonlytobemadeby
qualifiedserviceengineers(4).Improperrepairwork
cancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).
• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.
Wedonotacceptanyliabilityfordamagesinthecase
ofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).
• Alwaysunplugwhennotinuse.
• Onlyoperatethehumidifierwhenitiscompletely
assembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/
dismantlingofindividualpartsandbeforemovingthe
appliance.
• Donottouchthewaterinthebaseduringoperation
becauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonot
coverwiththrowrugs.Arrangecordsothatitwillnot
betrippedover.
• Neverpulltheplugfromtheoutletbythecableorwith
wethands.
• Donotusetheappliancewherecombustiblegasesor
vaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,
inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.
• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockor
damagetotheappliance.Donotblockairoutletsor
intakes.
• Donotpourwaterintothemistoutletoftheappliance.
• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugis
intendedtofitinapolarizedoutletonlyoneway.Ifthe
plugdoesnotfitfullyintheoutlet,reversetheplug.Ifit
stilldoesnotfit,contactaqualifiedelectrician.DONOT
attempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andthe
ACoutletmaycauseoverheatingandadistortion
oftheplug.Contactaqualifiedelectriciantoreplace
looseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsonthe
appliance.
• Donotsubmergethemainbodyinwaterorother
liquids.
• Disconnectpowersupplybeforeservicing.
• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsunderthe
influenceofmedication,alcohol,ordrugsarenot
permittedtooperatetheappliance,orareonlyper
mittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunction
useonlyclean,contaminationfree,cold,freshtapwa
terinyourhumidifier.Ifyourwatersourceiscontam
inatedorifyouareuncertainofitssafetyusedistilled
water.Inaddition,itisadvisedtoclean and maintain
your humidifierinatimelymanneras instructed in
this manual.
• Theuseofwateradditives,suchasethereal/essential
oils,fragrances,eucalyptus,waterconditionersetc.,
damagesthetankmaterialandasaconsequence
thewholeunit.Anyuseofsuchadditiveswillvoidthe
manufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehigh
frequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!

7
en
5
1
3
1ft
4ft
3ft
7
96
2
4
8

8
en
Foreword
Congratulations on choosing the Ultrasonic humidifier
7135!
Didyouknowthatdryroomair:
• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstinging
eyes?
• Encouragesinfectionsandillnessesofrespiratory
system?
• Causesweariness,tirednessandpoorconcentration?
• Stresseshouseholdpetsandhouseplants?
• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpets
andplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?
• Detunesmusicalinstruments?
General information
Acomfortableatmosphereindoorsisreachedwithare
lativehumiditylevelbetween40and 60%.Yourhumidi
fier automatically controls the humidity level according
todesiredsetting.Iftheairistoodry,thehumidifierwill
automaticallyswitchon.Assoonasthedesiredhumidity
levelisreached,itwillswitchoff.
Unpacking
• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthe
box(10).
• Warning:Donottaketheunitoutoftheboxbypulling
uponthetankhandlebasemayfallandwillbeda
maged(11).
• Warning:Themistoutletispackedinaredbaginside
theboxinsert.Makesurethatyouremovethemist
outletfromthepackaging(12).
• Removetheplasticbagfromthehumidifier.
• Observetheinformationgivenontheratingplateabout
thevoltage.
• Usetheoriginalpackagingforstoringtheapplianceif
youdonotusethehumidifierallyearround.
10
11
12

9
en
Setting up
Findingtheideallocationforyourunit:
• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureof
themistcandamagethefloorsurface(6)(seeSafety
Instructions).
• Theunitshouldbeplacedinanelevatedposition(7),
e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,
furniture,orotherobjects(13).Keepdistanceofat
least20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(14).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshould
bereplacedevery2–3monthsdependingonyour
waterhardness.Someareasmayneedtoreplacethe
cartridgesooner,somemaylastlonger.Thecartridge
mustbeexchangedatthelatestafter6monthsorthe
unitdoesnotreachitsfullperformanceanymore.
See«Replacementofthedemineralizationcartridge».
• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(15and16).
• Placethewatertankontothebase.
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).
• About10to15minutesafteritisswitchedonthe
devicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged
(2).
Membrane
Controlpanel
Airinlet
Mistoutlet(rotating)
Demineralizationcartridge
Watertank
Evaporationchamber
Brush
Waterbase
Powerplug
Waterlevelsensor
Mainbody
Description of the appliance
Watertankcap
HydroCell
24 h
14
13

10
en
17
18
16
15
Filling the tank
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Toprotecthealth safetyandproper humidi-
fierfunctionuseonlyclean,contaminationfree,
cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofits
safetyusedistilledwater.
Do not operate the humidifier when the water tank is
empty!Whenthewaterreachestheminimumlevel,theunit
switchesoffthenebulizerfunctionautomatically.Thered
lightcomesonindicatingtankisempty.
•Removethewatertankfromthebaseandunscrewthe
watertankcap(15).Caution:themistoutletisloose!
• Makesurethatnoforeignobjectsareinthewater
tank.
• Fillthetankwithclean,coldwaterfromthetap(16).
Closethecapofthewatertanksecurely,placethe
watertankontothebase(17).Thewaterisnow
runningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance
(18).
• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offbutton(19).Theredempty
indicatorlightmaystayilluminatedforsomeseconds
untilthebaseisfilledwithwater.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Evenasmallamountcancausecracksinthematerial.The
materialisn’tmadefortheuseofsuchadditives.Onedrop
isenoughtodamagethetankandasaconsequencethe
unit.Anyuseofsuchadditiveswillvoidthemanufacturer’s
warranty.
19

11
en
C) Timer
Using button C, the operation time can be set adjusta
blebetween 1and9 hoursor co(continiousoperation).
Symbol Gshowstheoperatingperiodthathasbeenset
(1h/2h/3h/4h/5h/6h/7h/8h/9h/co).Thedisplaywillautomat
icallyshowthecurrentvalueafterafewseconds.
D) Mist output (regulating mist output)
The mist output can be regulated by pressing button
Dseveral times. If thered barsare displayed, you have
selectedthehighestlevelofmistoutput(symbol H).
E) Operation with water pre-heating
(warm mist)
ButtonEisusedforswitchingthepreheatingonandoff
(symbol Ilightsup).Asaresult,thewaterispreheated
toatemperature of 176°F(80°C) before enteringthe
nebulizerspace.Ittakesapprox.10to15minutesforthe
waterinthebasetowarmup.Themistnowleavesthe
humidifieratapleasanttemperatureof104°F(40°C).The
advantageofthisisthattheroomtemperaturedoesnot
dropand,in addition, it significantly improves the water
qualitymaintenance.
F) Automatic mode and Sleep mode
Theautomaticandsleepmodescanbeactivatedbypres
singbuttonF.Bypressingthebuttononce,theautomatic
functionisswitchedon(symbol Jappearsonthedisplay),
maintainingtheoptimumhumiditysubjecttothetempera
ture.Controltakesplacebymeansofoutputquantityand
presettargetvalue.Ifthesleepfunctionisswitchedon
(thesymbol Kappearsonthedisplay),thetargethumidity
is60%;theoperationtimeisautomaticallysetat8hours;
theheatingisswitchedon.Inaddition,theoutputquantityis
alsocontrolledsubjecttothedifferencebetweenthetarget
valueandtheactualvalue.
TheTimercannotbechangedineithermode.Ifotherbut
tonsarepressed,theunitwillnolongerbeinautoorsleep
mode.
A) On/ Off button
YoucanswitchtheunitonoroffbypressingbuttonA.This
buttonisalsousedtoresetthecleaningindicatorlight(by
holdingdown).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity
level in %. A relative humidity between 40% and 60%
isrecommended.Theaccuracyofmeasurementis+/5%.
Theunitwillswitchoffwhenthemoisturelevelexceedsthe
desiredsetting.Thedevicedoesnotswitchoffifthedis
playissetto«Co»(continuousoperation).Duringselection
thetargetvalueisdisplayed.Thedisplaywillautomatically
showthecurrentvalueafterafewseconds.
Operation 7135 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
Thewaterleveliseasytosee,thankstothetransparent
watertank.Theappliancealsoalertsyouwhenthewater
tankisempty.Theemptyindicatorisilluminated(symbolL).
Pleasereadthechapter«Fillingthetank»formoreinforma
tion.ThesymbolLmaystayilluminatedforsomeseconds
witharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicator
IfsymbolMand«CLEAN»appearonthedisplay,theappli
anceshouldbecleanedasrecommendedbythemanufac
turer.Thissymbolcomesonautomaticallyevery2weeks,
dependingonthelevelofuse.The display can be reset
by holding down button A until the light disappears.
A
BC
DEF
M
LG
HIKJ

12
en
ACID
22
2521
24
Cleaning/Maintenance
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Caution – risk of electric shock and
damage of the product!
• Switchofftheapplianceandunplugitfromthesocket
beforecleaningit(20).
• Cleanthewatertankandthebaseregularly.Usewater
only,nodetergents(21).
• UseEZCalandEZCalProcustomcleaninganddesca
lingagentsonlytoremovedepositsfromthememb
raneregularly(22and23).ThereisasampleofEZCal
includedinthepackagingofyourhumidifier.Instruc
tionsforusingareonthepacket.Onlyuse1packetfor
32ozofwater.Donotchangetheratio.DoNOTrunthe
unitwhenusingEZCalandEZCalPro.Thiscancause
damagetotheproductandvoidsthewarranty.Tho
roughlyrinsethebasewithtapwaterafterusingEZCal
andEZCalProandmakesurenoEZCalandEZCalPro
residuesremainsinthebase.
23
20
26

13
en
27
Water quality maintenance
TheHydroCellkeepshumidifiersoperatingattheirhighest
levelbetweenrecommendedcleanings.Goodforapproxi
matelyonetotwomonths,dependingonthewaterquality,
theHydroCellensuresthehumidifier’sfunctionalitywhile
providing fresh humidification performance. It starts to
workassoonasitcomesintocontactwithwater,even
iftheunitisturnedoff.TheHydroCellshouldbechanged
everyonetotwomonths*.Lookatpicture27/28forthepo
sitionoftheHydroCellinthewatertankoftheunit.Switch
offtheunitfirst.Contactyourlocalretailerorcheckour
websitewww.airoswiss.netforreorderinformation.
*Dependingonthewaterquality. 28
EZCalandEZCalProaretheonlyrecommended
cleaninganddescalingsolutions.DoNOT use
anyothercleaningsolutionssinceitcandamage
theproduct.Anyuseofcleaningsolutionsapart
fromEZCalandEZCalProwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater
(24)!
• Thecleaningindicatorstillappearsonthedisplayafter
cleaning.ToresetitholddowntheON/OFFbuttonuntil
thecleanlightstopsflashing.
• Cleantheinnerpartswithasoftcloth.Donotuseany
solventsoraggressivecleaningagentstocleanthe
appliance(25).
• Onlyusethebrushtocleanthemembrane.Thisshould
bedoneonceaweek.Onlyusethesoftbristleportion
ofthebrush(26).
• Changethewaterinthetankatleastonceaweekif
waterisstandingformorethanaweek.

14
en
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
watertank.Donottouchthewaterinthebase
duringoperation!
Thewatertankisequippedwithademineralizationcartridge.
This cartridge has to be replaced every 2 – 3 months. If
thewaterisveryhard,itmaybenecessarytoreplacethe
cartridgeearlier.Whitedustaroundthedeviceisasuresign
thatthecartridgeneedsreplacing.Please note whitedust
isnotharmful.Ifwhiteresiduestillformsaroundthedevice
afteranewcartridgehasbeeninserted,pleasemakesure
thatthewateryouareusingisuntreated.Ifthewaterflows
throughadecalcificationsystem–suchasanionexchanger
–(sodiumisaddedtoremovecalcium)inthebuildingbefore
itisusedinthehumidifier,saltcanprecipitateaswhitedust
aroundthedevice.Thedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6monthsor
theunitdoesnotreachitsfullperformanceanymore.
Option A: replace the resin
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
•Openthecartridge(31).
•Throwthecontentintothewaste(Attention!Disposed
resincanmakethefloorslippery!)(32).
•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwill
bedifficulttoremoveafterwards(33).
•Pourthecontentsofonerefillresinbagintotheplastic
cupthatisincludedwiththerefillresinpackaging(34).
•Placetheemptycartridgewiththepluginthecenter
ontotheplasticcup(35).
•Turntheplasticcupandcartridgeoverandshakeuntil
allresinisinthecartridge(36).
29
30
31 32
•Removetheplasticcupandthepinkstyrofoampiece
fromthecartridge(37)andretainforfutureuse(the
refillresinconsistsof3refillbags)(38).
•Closethecartridge(39).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).
•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(44).
Placinggranulesinthecenterofthecartridge
allowsthemtoescapeintheunitortoclogthe
unit.Theunitwillnolongeroperateproperlyand
thegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge
•Removethewatertankfromthebaseandunscrewthe
watertankcap(29).Caution:themistoutletisloose!
•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningit
counterclockwise(30).Important:doNOTdisposeof
thewatertankcap!
• Throwthewholecartridgeintothewaste(40).
•Unpackthenewcartridge(41).
•Soakthedemineralizationcartridgeinawaterbath
24hoursbeforeusingit(42).Theresinhastoabsorb
watertoreachmaximumperformance.Ifitissoakedin
thetank,makesuretoexchangethewaterandempty
thewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(43).Close
tankcapwellandplacethetankonthemainbody
(44).

15
en
44
43
33 34
35
36
37
38
40
24 h
42
39
41

16
en
Technical data
Electricalvoltage 120V/60Hz
Powerconsumptionupto 45W/(140W*)
Humidityoutputupto 3.5gallons/24h*
Suitableforroomsupto 650sqft/60m2
Dimensions(LxWxH) 15x8.7x13.8in
38x22x35cm
Weight(empty) 7.7lbs/3.5kg
Accessories 7531Demineralizationcartridge
HydroCellA200
EZCalA7417
EZCalProA100
*whenusedwithpreheatingto176°F(80°C)
Storing the appliance for extended periods
Cleantheapplianceasdescribedearlierandallowtodry
thoroughly.Preferablystoretheapplianceinitsoriginalbox,
inadryplaceawayfromhightemperatures.
Legal notice
ThehumidifieriscULlisted.
Subjecttotechnicalchange.Theinstructionsforuseare
protectedbycopyright©PLASTONAG.
Accessories
Contact your local retailer or check our website www.
airoswiss.netforreorderinformation.
Customer Service
CustomerService(USA)18003360326
www.airoswiss.net
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCalandEZCalPro
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow
withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min.
thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandEZCalProandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste

17
en
General Humidifier Questions
Q.Why isn’t there enough moisture in my room?
A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropif
moistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the
unit is running?
A. a) Byleavingthedooropen,thisallowsmoistureto
leavetheroomandgointootherareasofthehouse.
Ifyouwouldlikethemoisturetostaywithinone
specificroomyoushouldconsiderclosingthedoor
whiletheunitisrunning.
A. b) Wood,leather,carpet,curtains,andothertypesof
fabricsoakupalotofmoisture,thusnotleavingen
oughmoisturefortheair.Ifthewindowisleftopen,
thenthisallowsmoisturetoescapetheroom.Ano
therfactorisalotoftimestheunitisplacednextto
aheatingdevice.Theideaisthattheairblowing
intotheroomwillquicklyplacemoisturearoundthe
room.Unfortunately,thisconceptdoesnotwork
becausethehotaircomingoutofaventwillsoak
upmostofthemoisture,andnoneoftheairwithin
theroomwillreceiveany.
Q.How much moisture do I need in my room?
A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much
humidity?
A. Dryaircancausedryskin,staticelectricity,outoftune
musicalinstruments,increasedlevelsofdust(dryair
causesdusttorise),damagetowoodenobjects(dry
outandeventuallycracksappear),discomfort,sick
ness,anddriesoutnasalmembranes.
Overhumidifyingtheaircancausemoldandwallpaper
topeel.
Q.Why do I need a humidifier when I can just open
my window?
A. Themoisturelevelwithintheoutsideairisnothigh
enoughtohumidifyaroom.Thecoldertheairtheless
moistureitiscapabletohold,andthemoretheairis
heatedupthepercentageofrelativehumidityislower.
Relativehumiditymeanstheamountofwatervaporin
theair,comparedtotheamounttheaircouldholdifit
wastotallysaturated.Thedifferenceishigherbetween
outsideandinsidetemperatures;morehumidification
isneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?
A. Theunitshouldbefreestandingandnotclosetoa
wall,window,door,orthermalbridgesothatairmay
circulatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization
cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetouse
therefilloptiontoreplacethegranules;thepurposeis
forhowtoopenandclosethecap.Ifyoudidopenthe
capbeforeplacingitinthewatertank,youwillmost
likelynoticethattherearegranulesinthewatertank
andthebaseoftheunit.Immediatelyturnofftheunit,
andemptythewateroutofthebaseandthewater
tank.Beginremovingallgranulesfrombaseandwater
tank.Usebrushtocleanaroundmembrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q.I just replaced my cartridge, and the contents and
water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreven
thegranules,arereplaced.Thisdoesnotoccurwithall
replacementcartridgesorgranules,andisareactionof
watercontentandtheUltrasonicvibrations.Thisisnot
anindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far
may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybe
filledallthewaytothetop.
Q.What is the purpose of the demineralization
cartridge (DMC)?
A. TheDMCremovesmineralsfromthewatertoprevent
whitedust.Thecontentsofthecartridgeneedtobeso
akedfor24hrspriortofirstusingtheunitsothatthey
mayfullyexpandandremovemineralsfromthewater.
ThecontentsoftheDMChavealifeof2–3months.
Thecartridgemayneedtobereplacedmoreoften
dependingonwaterhardnessandhowoftentheunit
isused.AnindicationofwhentheDMCneedstobe
changedcanbewhitedustorreducedamountofmist
output.
Q.Is it ok to use distilled water with the unit?
A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverseosmosiswaterandremovethe
demineralizationcartridge.
Q.I just replaced the contents of the cartridge and
now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddle
ofthecartridge.Placinggranulesinthemiddleofthe
DMCallowsthemtoescapeintheunit.Immediately
turnofftheunit,andemptythewateroutofthebase
andthewatertank.Beginremovingallgranules
frombaseandwatertank.Usebrushtocleanaround
membrane.
Caution:Donotdisposeofgranulesinsink!Used
granulesmustgoinwaste!
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidity
intotheair.Becauseofthis,thecarpetingorwoodfloor
surroundingtheunitmaybecomedamp.Iftheunitis

18
en
placedatleast3feetoffthefloor,themistwillhavethe
opportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.
A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donot
pourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unit
A.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess.
Solve the problem:
•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoaked
inthewatertank,thewaterinthetankandthebase
needstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter12
monthswhenyouuseveryhardwater(forsofterwater
after23months).Nomatterhowhardyourwater
is,exchangethecartridgeattheverylatestafter6
months.
•Don’tusewaterfromapreinstalledwatersoftener,
orsodiuminsteadofcalciumwillbeemittedfromthe
unit.Usedistilledwaterinsteadandremovethedemi
neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterand
removethedemineralizationcartridge.
•UseReverseOsmosiswater(ROwater)insteadofdis
tilledwaterandremovethedemineralizationcartridge.
•Cleaning light is illuminated (digital models)
Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donot
submergethebase!Visuallyinspectthebasefordirt
ormineralbuildup.Ifsoftwaterisuseddecalcifying
theunitevery4weekswithEZCalissuggested.Ifhard
waterisusedtheunitshouldbedecalcifiedevery2
weeks.Donotforgettoresetthecleanlightafter
resettingtheunit.
Q.Reset cleaning light (digital models)
A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)
untilthelightstopsflashing.Thelightautomatically
comesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmost
areoffby+/5%.Plusthehumiditylevelisnotthe
sameinthewholeroom.Theaircirculationisdifferent
ineverycorneroftheroom.Theunitshouldnotbe
placednearaheatingventoraradiatorastheheatwill
absorballofthemoisture.
Q.Humidity level is not changing or does not reach
the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceper
day,theunitisworkingproperlyandtheclimaticcon
ditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:
•aircirculationisveryhigh(airisfullyexchangedse
veraltimesperday–thehumidifierneedstostartsits
workfromscratch)
•insulationofhome(seeaircirculation)
•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–highrisebuil
dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitis
verycoldoutsidedon’topenthewindowmorethan2
timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinside
temperature–thecoldertheairthelessmoistureit
iscapabletoholdandthemoretheairisheatedup
theloweristhepercentageofrelativehumidity(=the
amountofwatervaporintheair,comparedtothe
amounttheaircouldholdifitwastotallysaturated)
•positionoftheunitifitisplacedclosetoadoor,win
doworairvent.Thisincreasestheaircirculation.
Q.Tank is leaking
A. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunder
thewarranty.Pleasecontacttheretailertheunitwas
purchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mist
A. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbe
playedwith.
Q.No mist / unit is not working / empty indicator
keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthrough
thedemineralizationcartridge(attachedtothewater
tankcap).Ifthewatertankisfullbutthereisonlylittle
waterinthebaseitindicatesthatthewaterisnow
flowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutof
theunit.
•Iftheunitisnotworkingandtheemptylightisnotflas
hingyoumighthavesetthedesiredhumiditytoolow
andthecurrenthumiditylevelintheroomishigher.
Thatiswhytheunitswitchesoffautomatically.
•Iftheemptyindicatorkeepsflashingandthetankis
full,thewaterisnotflowingthroughthecartridge.
Exchangethecartridgeorthegranulesinthecartridge
after23months,inareaswithhardwaterexchange
thecartridgeafter12months.However,thedemi
neralizationcartridgeandorthegranulesmustbe
exchangedatthelatestafter6monthsortheunitdoes
notreachitsfullperformanceanymore
•Ifthegranulesarenew,seethefollowinginstructions:
•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwater
tofilterthroughthecartridgeandintothebase.Next,
pleaseremove2tablespoonsofgranulesfromthe
cartridge,andthrowthemaway.Whentherearetoo
manygranulesinthecartridgeitdoesnotallowwater
toflowfromthetanktothebase.

19
en
Q.Water tank cap is too tight to unscrew
A. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthe
watertankcaptoreleaseairfromthewatertank.
Continuetodothisuntilyouareabletounscrewthe
watertankcap.
Q.Unit is running intermittently.
A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If23monthshavepassed,
itistimetoreplacethecontentsofthecartridge.
Howeverthedemineralizationcartridgeandorthe
granulesmustbeexchangedatthelatestafter6
monthsortheunitdoesnotreachitsfullperformance
anymore.
•Ifthecontentsofthecartridgewerejustreplacedthere
areprobablytoomanygranulesinthecartridge.Re
move2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the
demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiece
thatattachesthedemineralizationcartridgetothe
watertank).
Q.What is the Hydro Cell and how long is it good for?
A.TheHydroCellkeepshumidifiersoperatingattheir
highestlevelbetweenrecommendedcleanings*.Good
forapproximatelyonetotwomonths,dependingonthe
waterquality,theHydroCellensuresthehumidifier’s
functionalitywhileprovidingfreshhumidification
performance.Itneedstobereplacedeveryonetotwo
months*.
*Dependingonthewaterquality.
Q.Placement of the Hydro Cell
A.Pleaseseepicture27/28forinstructions.
Q.What is EZCal and EZCal Pro?
A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalandEZCalProare
usedforcleaninganddescalinganyofthehumidifiers
andcleansmineralbuildup.EZCalandEZCalProare
theonlyrecommendedcleaninganddescalingsolu
tions.DoNOTuseanyothercleaningsolutionssinceit
candamagetheproduct.Anyuseofcleaningsolutions
apartfromEZCalandEZCalProwillvoidthewarranty.
Instructionsforusingareonthepacket.Onlyuse1pa
cketfor32ozofwater.Donotchangetheratio.Itcan
alsobeusedforotherhumidifierbrands.Thoroughly
rinsethebasewithtapwaterandmakesurenoEZCal
andEZCalProresiduesremainsinthebase!EZCaland
EZCalProareavailableatselectedretailstoresand
onlinewww.airoswiss.net.