0000100435/010812/0 FUA-1300/4700 EN - 5
Modications
Modicationof(partsof)theproductisnotallowed.
Installation
- Theinstallationofthisproductisexclusivelyreservedto
authorised,well-trainedandqualiedengineers.
- Inspecttheproductandcheckitfordamage.Verifythe
functioningofthesafetyfeatures.
- Electricconnectionistobeexecutedinaccordancewithlocal
requirements.EnsurecompliancewiththeEMCregulatory
arrangements.
- Duringinstallation,alwaysusePersonalProtective
Equipment(PPE)toavoidinjury.Thisalsoappliestopersons
whoentertheworkareaduringinstallation.
- Neverinstalltheproductinfrontofentrancesandexits
whichmustbeusedforemergencyservices.
- Mindanygasandwaterpipesandelectriccables.
- Makesurethattheworkshop,inthevicinityoftheproduct,
containssufcientapprovedreextinguishers.
Use
WARNING
Firehazard!Neverusetheproductfor:
- extractingammable,glowingorburningparticles
orsolidsorliquids
- extractingofaggressivefumes(suchas
hydrochloricacid)orsharpparticles
- suckingcigarettes,cigars,oiledtissues,andother
burningparticles,objects,andacids
WARNING!
Neverusetheproductfor:
- aluminium laser cutting
- paint mist
- extractionofhotgases(morethan80°C/176°F
continuously)
- grinding aluminium and magnesium
- amespraying
- extractionofcement,sawdust,wooddustetc.
- suckingcigarettes,cigars,oiledtissuesandother
burningparticles,objectsandacids
- explosive environments or explosive substances/
- gases
Note: this list is not all-embracing.
- Checktheworkingenvironment.Donotallowunauthorised
personstoentertheworkingenvironment.
- Protecttheproductagainstwaterandhumidity.
- Makesuretheroomisalwayssufcientlyventilated;this
appliesespeciallytoconnedspaces.
- Usecommonsense.Stayalertandkeepyourattentionto
yourwork.Donotusetheproductwhenyouareunderthe
inuenceofdrugs,alcoholormedicine.
Service, maintenance and repairs
- Duringservice,maintenanceandrepairjobs,alwaysuse
PersonalProtectiveEquipment(PPE)toavoidinjury.This
alsoappliestopersonswhoentertheworkareaduring
installation.
- Alwaysusetools,materials,lubricantsandservice
techniqueswhichhavebeenapprovedbythemanufacturer.
Neveruseworntoolsanddonotleaveanytoolsinoronthe
product.
- Safetyfeatureswhichhavebeenremovedforservice,
maintenanceorrepairs,mustbeputbackimmediatelyafter
nishingthesejobsanditmustbecheckedthattheystill
functionproperly.
4 INSTALLATION
4.1 Unpacking
Checkthattheproductiscomplete.Thepackageshould
contain:
- extraction fan
Options and accessories
TheMB-FUA/S1-2shouldcontain:
- mountingbracket
- connectionangewithgrid(S1only)
- tubeclamps(4)
- hardware
TheMB-FUA/C1-2shouldcontain:
- mountingbracket
- connectionange(C1only)
- hardware
TheOL(outlettransition)shouldcontain:
- squaretoroundoutlettransition
TheSC(softconnection)shouldcontain:
- softconnectionwith2hoseclamps
Ifpartsaremissingordamaged,contactyoursupplier.
4.2 Installation
4.2.1 Tools and requirements
Thefollowingtoolsandrequirementsareneededtoinstallthe
product:
- wrench10
- wrench13
- wrench17
- screwdriver
4.2.2 Installing the fan on an MB-FUA-S1/S2
Foruseasastandaloneorformountingonthewall,ceilingor
aplatform.Themotorcanbeinstalledrestingonthestand.
ThemotoroftheFUA-1300/1800/2100 can also be installed
upsidedown(hangingfromthestand,notshown).
ToinstallthefanonanMB-FUA-S1/S2 stand,proceedas
follows:
Fig. 4.1
• Installthestandinthedesiredplace.
• Attachthetubeclamps(B)asdesired,ifapplicable.
• Tightenthetubeclampswithsuitablehardware(not
supplied;materialdependingonwall,oororceilingtype).
• Positionthefanonthestandasdesired.
• Tightenthebolts(A).