Pocket home PH-BP1-V User manual

PH-BP1-VPH-BP1-V
PocketHome®
WIRELESS TRANSMITTER
- THERMOSTAT FOR ZONE CONTROL
OF FLOOR HEATING
• Element of the PocketHome®system
• Transmitter for the PH-BP1-P9 receiver
• Detects the room temperature and
sends requirement for circuit switching
P
DISPLAY DESCRIPTION: CONTROL ELEMENTS:
: used for selection of functions
: selection of preset temperatures
: information button (when pushed in the AUTO
mode, it gradually shows information on the
required temperature (PO:t), current hour/
temperature (CL:O/tE:P), operating hours
(SU:MA) and day (dE:n).
confirmation button (ENTER)
for selection of functions and temperature
setting
1, indication of the preset time and temperature
program
2, indication of the selected function AUTO, MANU,
PROG, etc.
3, indication of anti-freeze temperature (3°C)
4, indication of temperatures, comfortable ,
economical , party P
5, indication of time / temperature
Fce
i
1
2
3
4
5
P

The PH-BP1-V transmitter in connection with the 9-channel receiver PH-BP1-P9 is used for wireless
control of individual rooms (zone control) in a floor heating system. There is no need to install any con-
necting cables between the receiver and transmitters (room thermostats)! The entire set can be included
in the PocketHome®system and all zones controlled from a single point by means of a central unit and/
or through a PC. In that case it is first necessary to activate the PH-BP1-V transmitter in the central unit
(see Putting in operation in the PocketHome®system)!
In objects which do not necessitate central control the assembly can also work autonomously without a
central unit. The PH-P1-P9 receiver can be controlled by means of up to 9 PH-BP1-V transmitters.
DESCRIPTION
INSTALLATION
1) The transmitter is easily portable, yet we recommend that it be located in a suitable place where its activity will not
be affected by direct flow of hot air from a heater, solar radiation or other disturbing effects. Also avoid its
installation on an external wall.
2) Install the transmitter (indoors) as far as possible (at least 0.5 m) from big metal objects and from power lines to
avoid interference of signal reception!
3) We recommend that the installation be done by a person adequately qualified in electrical engineering!
4) To prevent interference and affection of systems, every system is protected by its unique factory-saved code!
5) For correct communication of all elements in the PocketHome®system with the PH-CJ37 / Plus central unit, the
code must be learned = every element ACTIVATED in the central unit!!!
6) As the entire system works at two-way radio frequency of 433.92 MHz, follow the installation and location
instructions!
! Caution:
LOCATION AND EXCHANGE OF BATTERIES
- Lift off the back part by pushing the latch at the arrow
and remove the protective paper from the batteries (at
first use); thus the transmitter becomes functional.
- Necessity to exchange the batteries is indicated by the
“Ba:tt” symbol flashing on the display (this information
can also be directly obtained on the central unit or in the
PC program (see the PH-CJ37/Plus manual).
- Always use alkaline batteries 2 x 1.5 V type AA
Dispose of used batteries in conformity with
regulations for dealing with hazardous waste! 2

Pushing the Fce button and then the button, you can choose the following functions:
1. AUTO : thermostat works according to the preset program.
2. MANU : used for manual setting of temperature (selection with the Pbutton or the
buttons; the temperature remains constant until the next change.
3. CL:O : current day and time setting.
4. PROG : programming mode.
5. PA:r : setting of parameters (constants).
6. OF:F : PH-BP1-V is switched off permanently in this mode (except for the “ “ mode ).
7. UA:dr : learning the unique number from the central unit / learning the code in the PH-BP1-P9 receiver
FUNCTIONS
Note: If no button is pushed within 2 minutes, the transmitter resumes the basic mode.
After long push, the button function speeds up.
PA:r1 options for data on the display
- Push the Fce button, chose the PA:r (parameters) function with the , confirm with i.
- PA:r1 appears on the display
- Confirm with the iand with the choose the option for displayed data in the basic
mode:
tcurrent temperature display
Ccurrent time display
- Confirm your choice by pushing the ibutton again.
PA:r2 economical temperature (17°C by default)
- PA:r2 appears on the display
- Confirm with the ibutton and set the economical temperature with the button; confirm
with the ibutton again.
1, Push the Fce button, chose the CL:O (clock) function with the button, confirm
with the i.
2, Time appears on the display and hour indication is flashing; set the desired value with the
button and confirm with the ibutton. Minute indication starts flashing; set the
desired value with the button and confirm with the i.button again. The day value
appears (d:1 Monday to d:7 Sunday); select the current day with the button and
confirm with the ibutton again.
TIME SETTING - CL:O FUNCTION current time and day

PA:r4 party temperature (25°C by default) P
- PA:r4 appears on the display
- Confirm with iand set the party temperature , confirm with ibutton again.
PA:r5 PI-control or hysteresis selection
- PA:r5 appears on the display
- Confirm by ibutton and choose with the buttons
PI:r for PI control (continue with setting the PI:r1 to PI:r3 parameters)
0.1 to 5 for HYSTERESIS (choose the hysteresis within the range of 0.1°C to 5°C)
and confirm ibutton again. HYSTERESIS = temperature difference between switching on/off.
PA:r6 Minimum switch-on time of the heating device at HYSTERESIS
If you choose HYSTERESIS, you must set the minimum switch-on
time of the boiler in minutes at hysteresis.
- PA:r6 appears on the display.
- Confirm by iand make a choice acc. to the heating system
used with the , see the table; confirm by ibutton.
PA:r7 Summer mode
- PA:r7 appears on the display; push the ibutton.
- Choose in the summer time without heating
- Choose the mode with the button; then push the ibutton.
The LE : tr symbol and temperature/time value alternate on the display.
PI:r1 Time period of PI control
If you choose PI control in PA:r5, you must set its parameters. Choose the time period in the
range of 5 to 20 minutes. Its choice is determined by the thermal inertia of the room.
The optimum setting is 10 to 15 minutes.
- PI:r1 appears on the display
- Confirm with the iand choose the time in minutes with ; confirm with the i.
PA:r3 comfortable temperature ( 23°C by default)
- PA:r3 appears on the display
- Confirm with iand set the comfortable temperature , confirm with ibutton again.
4
Heating
type
Minimum switch-on
time of the source
electric heating 1
panel radiators 2 (3)
cast-iron radiators 4
floor heating 5

PI:r2 Minimum switch-on time of the heating device at PI control
Selected in the range of 1 to 5 min. The setting is determined by the heating medium type and
depends on the selected time period of PI control.
We recommend setting according to the given table.
- PI:r2 appears on the display.
- Confirm iand choose the minimum time in minutes with
, confirm with the i.
PI:r3 Proportionality zone at PI control
This item specifies the value at which PI control starts working. Example: required temperature 22
°C, proportionality zone 1.5 °C. By 20.5 °C, the source is heating fully. When this value is reached, PI
regulation starts working. The PROPORTIONALITY zone can be set from 1.5 to 3.0°C.
- PI:r3 appears on the display.
- Confirm iand choose the proportionality zone in °C with ,
confirm with the i.
PA:rA address setting
- PA:rA appears on the display
- This parameter is set automatically after the thermostat is activated in the PocketHome®
system (see page 7).
- Push the ibutton or Fce button to return to function selection.
PA:r9 firmware version number / factory setting restoration
- PA:r9 appears on the display; This parameter is only informative and shows the firmware version number.
- Push the ibutton or Fce button to return to function selection.
- To restore factory settings, push the Pand button (! all changes will be deleted!) 5
PA:r8 Selection of HEATING/COOLING mode
- PA:r8 appears on the display; push the i.
- Choose the mode with the button; then push the ibutton.
Advantageous in the summer period, when you wish the connected air-conditioning to switch on at the
required temperature; in this mode, the control works inversely to the heating mode (if PA:r5=0.5 and
the required temperature is 23 °C, the controller switches at the current temperature of 23.5 °C).
Note: If the PH-CJ37/Plus central unit is the higher-level device, this option is blocked.
heating
cooling
Heating
type
Minimum switch-on
time of the source
electric heating 1
panel radiators 2 (3)
cast-iron radiators 4
floor heating 5

PROG FUNCTION program setting
- Push the Fce button and choose the PROG (PROGRAMMING) function with the button;
confirm with the ibutton.
- With the button, choose the date which you want to program acc. to the table
- After selection, push the ibutton, and the 1:U1 message appears on the display to set the
first time period.
- With the button, set the time of the first change (min. step of 10 min.).
- Repeatedly pushing the Pbutton, assign the required temperature to this time.
- Confirm with ibutton again; the display automatically shows 1:U2 message for the second
interval of the 1st day.
- Repeat the procedure until you set all time intervals (max. 6), and then exit the programming
mode with the Fce button.
- Choose the AUTO function and the thermostat starts working
according to the preset program.
d:1 Monday d:5 Friday d1:5 Monday to Friday
d:2 Tuesday d:6 Saturday d6:7 Saturday to Sunday
d:3 Wednesday d:7 Sunday d1:7 all week
d:4 Thursday TABLE FOR SELECTION OF PROGRAMMED DAYS
Thermostat state indication:
AUTO (or MANU) message on the display is LIT = connected device switched ON
AUTO (or MANU) message on the display is FLASHING = connected device switched OFF
OTHER FUNCTIONS
Short-term temperature change in the AUTO mode
Push the button in the AUTO mode; thus you can change the required temperature for a short time; the
thermostat maintains this temperature until the next temperature change given by the program (in the PocketHome®
system, the so-called INDEPENDENT MODE can also be assigned; for more, see the central unit manual).
OF:F FUNCTION permanently off
Push the Fce button and choose the OF:F function with the button; confirm with the i
button. Thus the thermostat is permanently switched off. In this mode, the OF:F message and
current temperature/time value alternate on the display. To cancel this function, push the Fce
button and choose another mode with the button.
“ LO:C” FUNCTION child lock
Used for locking the keyboard, protection against undesirable handling.
Push the Fce button, then simultaneously Pand the keyboard is locked (buttons -
functionless). The LOC (LOCK) message appears on the display shortly. To cancel, that means
unlock, push the Pand buttons simultaneously. 6

ERROR MESSAGES
If an error message appears on the display:
Er:r0 temperature sensor error (the internal temperature sensor is faulty) - CONTACT THE MANUFACTURERE IMMEDIATELY
Er:r1 signal transmission error (false signal transmission between the transmitter and receiver) - test correct connection and code
learning!
If the error message repeats, we recommend that you contact the manufacturer.
PROCEDURE OF PUTTING INTO OPERATION IN THE PocketHome®SYSTEM
Before activating PH-BP1-V, the central unit must be set and ready according to the PH-CJ37 / Plus manual (or SW
for PC)!
1. PH-BP1-V ACTIVATION - ESTABLISHING COMMUNICATION WITH THE CENTRAL UNIT
- On the PH-BP1-V transmitter, push the Fce button and choose the UA:dr function for
thermostat activation with the button; confirm with the i.
- The unique production number (0) appears on the display.
- Push the “Test” button on the central unit in the ACTIV mode for the given BP1 thermostat (see
the PH-CJ37 manual).
- The Pa:rA address will be assigned automatically.
- Push the “Test” button again, and the thermostat is activated in the PockerHome®system and
primarily controlled from the PH-CJ37 / Plus central unit (the AUTO+MANU message and
current time/temperature appear simultaneously on the display.
2. LEARNING THE RECEIVER CODE
Follow the PH-BP1-P9 manual.
DEACTIVATION FROM PH SYSTEM
When activated in the system in the UA:dr mode, every thermostat is gradually assigned an address from 1 to 255.
This address cannot be changed, yet the thermostat can be deactivated from PocketHome®system.
- On the transmitter, push the Fce button and choose the PA:r parameter setting function with
the button; confirm with the ibutton.
- Choose the PA:rA with the button and confirm with the ibutton again.
- You can deactivate the thermostat with the button if you choose the option - - : - -
(instead of the address, e.g. A:1). 7

Pb
LEAD FREE
in compliance with RoHS
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel.: +420 541 230 216
The guarantee period is 2 years. In the case of gua-
rantee or post-guarantee service, send the product
to the manufacturer’s address.
MADE IN CZECH REPUBLIC
DECLARATION OF CONFORMITY
We, ELEKTROBOCK CZ s.r.o., herewith declare that the pro-
duct PH-BP1-V is in conformity with basic requirements and
other corresponding provisions of the directive 1999/5/EC.
Kurim 1.8.2009 on www.elbock.cz
In the PocketHome®system, the transmitter detects current room temperature, receives information on
the required temperature from the central unit, and sends requirements to the receiver according to the
temperature difference. In connection with up to 9 PH-BP1-V transmitters, PH-BP1-P9 means a system
for complete control of floor heating.
Technical parameters
Power supply 2 x 1.5 V alkl. baterie type AA
Communication type two-way
Frequency 433.92 MHz
HF output < 10 mW
Number of temp.changes 6 na každý den
Hysteresis 0.1°C to 5°C by steps of 0.1°C
Min. program. time 10 minutes
Preset temperature range 3°C to +40°C
Temperature setting by 0.5°C
Min. indication step 0.1°C
Measurement accuracy ± 0.5°C
Protection class IP20
Working temperature 0°C to +40°C
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
Advantages:
- In the PocketHome®system, central control
from one point, quick overview of temperature
in every room.
- Temperature control in every room.
- By request, the receiver controls the distributor
thermo-valves and pump.
- The system is also able to work in autonomous
mode without the central unit.
- The E-EPROM memory keeps the codes even
in the case of power failure.
- Up to 30% energy saving.
up to
9 thermostats
www.elbock.cz
Table of contents
Popular Thermostat manuals by other brands

OJ Electronics
OJ Electronics UTCG-9991 instructions

Honeywell
Honeywell T8611 owner's guide

Contemporary Controls
Contemporary Controls BASstat Series user manual

Horstmann
Horstmann CENTAURSTAT 1 User instructions

Emerson
Emerson TS1 Series operating instructions

iPdomo
iPdomo Wi-Fi Thermostat Installation and user guide