Technical specification / user manual T6-RCU 4 / 6
III. Assembly
1. Set up the clock in a suitable place.
2. Install the board on a tripod.
3. Depending on the operation mode connect the control cable:
a) to the socket located on the display side, for the time control keypad or chronometer
b) to the socket located on the display bottom, for the numeric keypad
4. Connect the control cable to the power supply.
5. The clock tests led display units (all segments light up for about 2s).
6. Then the clock shows time 0s. and it is ready to use.
IV. Operating
1. Standalone operation –time control keypad
a) press USTAW/SET to adjust first two digits (hours HH), while the digits are fleshing press +to set up their
initial value, then press USTAW/SET again to adjust next two digits (minutes MM), repeat the sequence to set
up last group (seconds SS),
b) press START to start measuring time from the initially adjusted value,
c) press STOP to stop measuring time,
d) press and hold CLEAR/KASUJ for approx 2 s. to reset the clock.
Time display –time control keypad
Results control –numeric keypad