If the detector is mounted on a wall, its height should be higher than any window or door, but it must be at least 150mm from
the ceiling. If the detector is mounted on the ceiling, it should be at least 300mm from any wall.
The detector is at least 1m to 3m away from the potential gas source;
If there is a partition in the room, the detector should be on the same side of the partition as the source of potential gas;
In a room with a beveled ceiling, the detector should be on the high side of the room;
The detector should be located very close to the area that the occupants often breathe.
△
! WARNING
Drop, collision, may or complete loss of detection function.
Please avoid the following places unsuitable to install an alarm to avoid the damage or unnecessary false alarm or no alarm.
•Do not install the alarm behind drape or furniture
•Do not install the alarm in a path of air discharged from a furnace or air conditioning vent or ceiling fan
•Do not install the alarm in places that the temperature can easily drop to -10℃or rise to over 40℃
•Do not install the alarm in places with much lampblack or dust, which will easily block itssensor
•Do not install the alarm in too moist places
•Do not install the alarm directly above a sink or cooker