Polygroup UVS-1012 User manual

IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
7. SAVE THESE INSTRUCTIONS.
When installing and using this electrical equipment, basic safety precautions should always be followed, including
the following:
2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times by an adult who is capable of assisting a child in distress.
3. WARNING - Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault
circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section 680-31 of the National Electrical
Code. Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI.
4. WARNING - To reduce the risk of electrical shock, replace damaged cord (with pump body) immediately.
NEVER bury cord. Locate cord to eliminate abuse or contact from lawn mowers, hedge trimmers, and other
equipment. NEVER use an extension cord to connect unit to electric supply; provide a properly located outlet.
2
2
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
Customer Service: (888) 919-0070 • www.polygroupstore.com
UV SANITIZER (UVS-1012) OWNER’S MANUAL
FOR ABOVE GROUND QUICK SET® SWIMMING POOLS
LIMITED WARRANTY
Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original purchaser only,
the UV Sanitizer against defects in material and workmanship for 180 days from the date of purchase. Original
Purchaser must retain proof of such purchase in the form of an original store sales receipt and must produce such
upon request by Polygroup or its designated agents. Warranty claims cannot be processed without a valid proof of
purchase.
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or
replacement of the product, to be decided in Polygroup’s sole discretion. Consequential damages, including claims
for loss of water, pool chemicals, damage, or labor are not covered under this Limited Warranty.
This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by
unauthorized persons; use non-Polygroup parts or accessories with the product; use the product in contravention
of the Manufacturers Instructions; use improper voltage; abuse the product in any way; or through accident or
negligence. Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the control of
Polygroup.
IN NO EVENT SHALL POLYGROUP,THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE
BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or others
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
Should you encounter a problem with your Polygroup Product, please do not return the product to the place or
purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Customer Service, please
first review the Troubleshooting Guide in the Installation Manual, or review the FAQ at www.polygroup.com . If you
are still unable to correct the problem, please contact Polygroup customer service at (888) 919-0070. Have the
product type and your purchase receipt ready. Our Customer Service Representative will assist you in resolving the
problem. You may be asked to return all or part of the product for inspection and/or repair. Do not return any
product to Polygroup without a Return Authorization number.
2X
2X
4X
5. CAUTION - For continued protection against possible electric shock, use only original equipment
manufactured (OEM) parts for your replacement requirements.
IMPORTANT SAFETY INSTRUCTIONS
PRELIMINARY STEPS
EXPLODED DIAGRAM
INSTALLATION
DISASSEMBLY AND STORAGE
MAINTENANCE
TROUBLE SHOOTING GUIDE
UV TUBE REPLACEMENT PROCEDURES
PARTS & ACCESSORIES
2
3
4
5
6
6
6
7
8
6. Modifications are not approved by the party responsible for compliance could void user’s authority to
operate the equipment.
Note:This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against
harmful interference in a residential installation.This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

3 4
4
Should you encounter any problems, contact the Customer Service at (888) 919-0070. Should you encounter any problems, contact the Customer Service at (888) 919-0070.
KEY DESCRIPTION
1 O-RING (RETURN FITTING ELBOW)
2 RETURN FITTING ELBOW
3 O-RING (RETURN FITTING ELBOW INTERNAL)
4 TOP COVER RETAINER
5 TOP COVER
6 HOSE RETAINING NUT
7 UV TUBE, 10W
8 UV TUBE SOCKET
9 WATERPROOF GLASS TUBE
10 BOTTOM COVER
11 WATER HOSE (IN)
12 WATER HOSE (OUT)
13 CORD CLAMP
14 PHILLIPS HEAD SCREWS
15 BALLAST
16 STRAIN RELIEF
17 EXTENSION CORD
18 POWER ADAPTER
19 MAIN HOUSING
20 O-RING (MAIN HOUSING)
21 PARTITION BOARD
22 O-RING (VENT SCREW)
23 VENT SCREW
24 HOSE ADAPTER (1.5”TO 1.25”)
25 HOSE CLAMP SCREW
26 HOSE CLAMP
27 POWER SWITCH
28 POOL WALL
FIG.1
POOL
RETURN
FITTING
POOL
WALL
FIG.2
POOL
RETURN
FITTING
POOL
SUCTION
FITTING
24
25
26
2 Ea.
4 Ea.
4 Ea.
3
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble
to your Type of Pool and Filter System.
2. Before you begin to assemble the UV Sanitizer, identify, count, and check all parts needed for assembly. Refer to
the“PARTS LIST”, Page #8.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC)
“Swimming Pools, Fountains and Similar Installations”or its latest approved edition.
3.The UV Sanitizer is manufactured by Polygroup and designed to be operated at 115 VAC 60 Hz. (ALL Units must
have a minimum of 105 VAC to start and run properly.)
PRELIMINARY STEPS
IMPORTANT NOTES:
UV Sanitizing System 20.0 Watts 0.4 amps
120VAC
FIG.3
21
22
23
12
20
19
17
16
15
14
13
14 10
14
27 8
7
9
6
5
4
3
2
1
11
28
4 Ea. 26
4 Ea.
12
3
26
2 Ea.
2 Ea.
2 Ea.
2 Ea.
18

5
5
Should you encounter any problems, contact the Customer Service at (888) 919-0070.
6
6Should you encounter any problems, contact the Customer Service at (888) 919-0070.
UV SANITIZER DISASSEMBLY AND STORAGE
A. First, unplug the UV Sanitizer. Insert the plugs for pool servicing to the pool wall. Disconnect the Water Hoses
from the pool wall.
B. Slowly unscrew the Vent Screw (23) from the Top Cover (5) to allow the filter system to depressurize.
C. Unlock the Top Cover Retainer (4) by turning counter-clockwise. Remove the Top Cover (5).
D. Loosen the Hose Clamps (26) to remove the Water Hoses (11, 12) and allow water to drain out.
E. Clean and dry all UV Sanitizer parts.
F. Liberally lubricate the O-rings (20, 22) at the Top Cover (5) on the Vent Screw (23) with petroleum jelly, and then
reassemble it along with the Top Cover (5), Vent Screw (23),Top Cover Retainer (4) onto the Main Housing (19).
Store all parts carefully.
1. Check the hose connections in the UV Sanitizer periodically to make sure there is no leakage of water.
MAINTENANCE
TROUBLE SHOOTING GUIDE
DISCONNECT ELECTRICAL CORD BEFORE TROUBLESHOOTING THE UV SANITIZER
SYMPTOM PROBLEM POSSIBLE SOLUTION
1 UV Sanitizer is not cleaning
pool (water cloudy, green,
AUV Tube failure AUnlock the Top Cover Retainer (4) and check the UV Tubes (7). Replace the UV Tubes if necessary.
2 Water Leakage AAdjust the Hose Clamp (26). Check O-ring (1) and retighten.Check water hoses for if there is any
A Connection points
holes or cracks. Replace if needed. See page #3.
BVent Screw BCheck O-ring (22) for damage.Replace if needed. Lubricate with petroleum jelly.
CTop Cover Retainer/ Top Cover CCheck O-ring (20) for damage. Replace if needed. Lubricate with petroleum jelly.
etc.)
Refer to the UV Tube Replacement Procedures on page #7.
1. UV SANITIZER INSTALLATION: (Refer to Page 3, 4; Fig. 1, 2, 3)
WARNING - EXTREMELY IMPORTANT!
• Risk of electrical shock, connect only to a grounding type receptacle protected by a ground fault circuit
interrupter, (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by
a GFCI.
• Receptacle must be at least 10 feet away from pool.
• Do not use an extension cord to connect unit to electric supply; provide a properly located outlet.
• Do not bury the cord.
NOTE - The UV Sanitizer consists of: UV Sanitizer; Power Adapter; Hardware Bag (Hose Adapters, Hose Clamps);
and Water Hoses.
The UV Sanitizer can be used with Skimmer Pump (Fig.1) or RP Pump (Fig. 2) filter system.
A. Remove all parts from the packaging box.
B. Make sure to switch off your swimming pool pump before connecting the UV Sanitizer to your pool.
C. Unscrew the Vent Screw (23) from the Top Cover (5). Get the Water Hoses (11, 12), and remove four Hose Clamps
(26) from the hardware bag. Loosen the Hose Clamp Screws (25) and slide the Hose Clamps (26) over one end of
each hose. Lubricate the O-rings (1, 22) on the Return Fitting Elbow (2) and the Vent Screw (23) liberally with
petroleum jelly.
D. Install the Water Hoses (11, 12) on each of the Return Fitting Elbow (2) on the UV Sanitizer.Tighten both of the
Hose Clamps (26). Remove the Water Hose which connects your existing pump outlet to the water return fitting
on the pool wall. Install the Water Hose (IN) (11) on the UV Sanitizer to the the pump outlet and tighten it with
the Hose Clamp (26). Install the Water Hose (OUT) (12) on the UV Sanitizer to the water return fitting on the pool
wall and tighten it with the Hose Clamp (26).
E. Unscrew the Vent Screw (23) from the Top Cover (5) about 2 turns. NOTE:VENTING THE SYSTEM IS NECESSARY
FOR AIR TO ESCAPE AS THE UV SANITIZER FILLS WITH WATER.
G. Start the swimming pool pump to allow water pumping into the UV Sanitizer.When the UV Sanitizer is full, water
should be coming out of the groove of the Vent Screw (23). Hand-tighten the Vent Screw into the Top Cover (5)
until the O-Ring (22) seals around the Vent Screw (23) and no more water is escaping.Check to ensure no
leakage at the Top Cover Retainer (4) and the Return Fitting Elbows (2), tighten them if necessary.
H. Press the Power Switch on the UV Sanitizer to start the sanitizing system for the swimming pool.
F. Connect the pins of the Extension Cord (17) from the UV Sanitizer to the Power Adapter (18).Tighten the screw
nut on the Extension Cord with the Power Adapter. Plug-in the Power Adapter to the power socket.

UV TUBE REPLACEMENT PROCEDURES
Should you encounter any problems, contact the Customer Service at (888) 919-0070. 7
7
2
12
3
11
4
10
5
1
13 14
6
9
8
For inquiry or customer service, please contact our service center:
Polygroup Services NA Inc.
1-888-919-0070 or visit our website: www.polygroupstore.com
Unscrew the Bottom Cover. Remove the Bottom Cover. Unscrew the UV Tube End Cover.
Remove the UV Tube End Cover. Take out the UV Tube Socket. Remove the UV Tube Socket from the
defective UV Tube.
Remove the defective UV Tube.
7
Insert a new UV Tube. Plug-in the UV Tube Socket to the UV
Tube.
Put back the UV Tube End Cover. Tighten the UV Tube End Cover with
screws. Put back the Bottom Cover.
Tighten the Bottom Cover with screws. Done.
1. WARNING - To reduce the risk of electric shock, the parts should be completely dry before servicing.
Disconnect from power source before servicing. Service should be done in indoor and away from water.
2. WARNING - Avoid direct exposure to UV light on eyes or skin. Germicidal ultraviolet rays are harmful
to the eyes and skin and can cause serious injury.
Table of contents
Other Polygroup Accessories manuals