Power works ARTEMIS 10PM User manual

USER MANUAL
ARTEMIS 10PM
ARTEMIS 12PM
ARTEMIS 15PM
ARTEMIS 10M
ARTEMIS 12M
ARTEMIS 15M

1
SAFETY INTRODUCTION
1.Please read the manual carefully and keep it for future reference.
2.All safety instructions and warnings must be adhered to. They are par t of the manual and must be kept
with the manual.
3.Any guarantee claims are rendered invalid if damage occurs due to non-observance of these operating
instructions. We assume no liability for any consequent damage.
4.We assume no liability for personal injury or damage to proper ty caused by incorrect handling or nono-
bservance of the safety instructions. Any guarantee claims expire in such cases.
5.Unauthorized conversions and/or modifications of the appliance are not permitted for safety and licensing
reasons (CE).
6.The appliance is approved for operation in dry, closed rooms only. Do not operate the device nearby water,
such as in bathrooms or nearby swimming pools.
7.The appliance may not be exposed to extreme temperatures (< +5°C / > +35°C) in operation.
8.The appliance may not be subjected to strong vibrations or heavy mechanical strain.
9.The appliance may not be exposed to excessive moisture (due to dripping or sprayed water, for example).
10.Do not place any recipients filled with liquids, such as glasses or vases, on top of or directly next to the
appliance. They could fall over, causing water to enter the appliance. Never pour out liquids above the
appliance. Do not place any small objects, such as coins or paper clips, on the appliance since they could
fall inside the appliance. You run a high risk of causing a fire or life-threatening electrocution! If any liquid
or objects enter the appliance never theless, pull the mains plug out of the socket immediately and contact
a specialist.
11.The appliance has been constructed according to protection class l. The power plug must only be plugged
into a protection class I outlet. The voltage and frequency must exactly be the same as stated on the device.
Wrong voltages or power outlets can lead to the destruction of the device and to lethal electrical shock.
12.110- 240 Vac, 50/60 Hz mains socket may be used as source of power for the appliance. Never try to operate
the appliance with any other voltage.
13.Only pull the mains plug out of the socket by the intended gripping surface. Do not pull it by the cable.
14.Never plug the mains plug in or out with damp or wet hands.
15.Always pull the mains plug out of the mains socket:
16.Before cleaning the appliance
17.If there is a thunderstorm
18.If you will not be using the appliance for a long period of time (>1 week)

2
19.Electrical appliances must be kept out of the reach of children. Be par ticularly careful if children are pre-
sent. Children are not aware of the hazards involved in handing electrical appliances improperly. Children
could attempt to poke objects into the appliance. There is a life-threatening danger of electrocution.
20.Do not leave the appliance unattended while operating it.
21.Never place the appliance on an unstable or movable surface. Persons could be injured or the appliance
damaged by it falling down.
22.When using a rack, make sure it is in a stable position and is transpor ted securely. Installation on uneven,
slanted surfaces or stopping the rack abruptly during transport can result in the rack over turning or applian-
ces falling from or out of the rack and injuring people.
23.Live components can be exposed by opening covers or removing components (unless this can be done wi-
thout tools). Contact points can also be live. If the appliance has to be opened in order to calibrate, service,
repair or replace components or assemblies, all of its poles must be disconnected from all sources of voltage
first. If the appliance has to be kept open and under voltage during maintenance or repairs, this work may only
be carried out by a specialist who is familiar with the risks involved and the relevant regulations.
24.Never connect the appliance directly after transferring it from a cold to a warm room. The condensation
water that forms could destroy the appliance or result in an electric shock. Allow the device to reach
room temperature before connecting it. Wait until the condensation water has evaporated. This can take
some hours.
25.Do not place any naked flames such as those of burning candles on or next to the appliance.
26.Do not place the appliance on soft surfaces such as carpets or beds. Do not cover the air vents of the
appliance. Do not obstruct the air circulation with objects such as magazines, table cloths or curtains. This
prevents the dissipation of heat from the appliance and can result in overheating.
27.Only use the appliance in a moderate climate, not in tropical environments.
28.All persons involved in operating, installing and servicing the appliance and putting it into service must be
trained and qualified accordingly and observe these operating instructions.
29.Defective mains cables may only be replaced by specialists. Danger of shock hazard!
30.Do not leave the packaging material lying around carelessly since it can become a source of danger for
children playing with it.
31.The accident prevention regulations and the regulations of the employers’ liability insurance association
should be observed at commercial institutions.
32.If you are not sure about the correct connection or if questions arise which are not answered by the
operating instructions, please do not hesitate to contact support or a specialist of your choice. Consult a
specialist if you are in doubt about the operating principle or the safety of the product.

3
ARTEMIS 10P MON
ARTEMIS 12P MON
ARTEMIS 15P MON 2
145
3
6
7 8 9
1.LEVEL
Control to adjust the LINE input level. Turn the knob clockwise or counter-clockwise to increase or decrease
the input volume.
2.MONITOR/FOH button
Use this switch to select various EQ characteristics, suitable for different applications.
MONITOR: For use as stage monitor with feedback suppression.
FOH: For use as PA speaker (front of house).
3.INPUT
Line input 1, designed as XLR / 1/4" combo socket, balanced.
4.LINK
This outlet can be used to feed the signal to fur ther active speakers.
5.Ground/Lift button
If a ground loop is causing hum you can use this switch to cut the connection between the ear th pin of the device
and the signal ground in the device.
6. POWER SWITCH
Switch up to turn the speaker on, and switch down to turn it off. Make sure the level control is down before
you turn it on.
7.VOLTAGE SELECT SWITCH
Switch for setting the operating voltage. The mains voltage of your power supplier and the operating voltage of
the device must be the same!
8.Fuse holder
In case of fuse burn, to prevent the risk of fire and damaging the unit, Before replacing the fuse, make sure the
unit turned off and disconnected from the AC outlet.
9.IEC Socket
Plug the line cord into an AC socket properly configured for your par ticular model.

9
TECHNICAL SPECIFCATIONSTECHNICAL SPECIFCATIONS
Model:
Frequency response:
Type:
Max.SPL (Peak)
LF transducer
Pole Socket
Power output(RMS/peak):
Weight:
ARTEMIS 10PM
Active Stage monitor
60Hz-19kHz
250W/500W
121dB
10"Woofer 2"Voice coil
14kg
35mm
Amplifier Type
Connectors Input
Connectors Output
Input: XLR/6.3mmTRS combo jacks
Output: XLR
ARTEMIS 12PM
55Hz-19kHz
300W/600W
123dB
12"Woofer 2.36"Voice coil
17kg
ARTEMIS 15PM
45Hz-19kHz
350W/700W
125dB
15"Woofer 3"Voice coil
23kg
Dimensions(WxHxD): 465 x 555 x 418 mm 536 x 585 x 463 mm 580 x 685 x 490 mm
Active Stage monitor Active Stage monitor
LF transducer 1" Exit-1.35" Compression Driver
Class D + Class AB Class D + Class AB Class D + Class AB
Dispersion angle (HxV): 80° x 80° 80° x 80° 80° x 80°
Model:
Frequency response:
Type:
Max.SPL (Peak)
LF transducer
Pole Socket
Power output(RMS/peak):
Weight:
ARTEMIS 10M
Passive Stage monitor
60Hz-19kHz
300W/600W
94dB
10"Woofer 2"Voice coil
13kg
35mm
Connectors 2 x Speakon
ARTEMIS 12M
55Hz-19kHz
350W/700W
95dB
12"Woofer 2.36"Voice coil
16kg
ARTEMIS 15M
45Hz-19kHz
400W/800W
96dB
15"Woofer 3"Voice coil
21kg
Dimensions(WxHxD): 465 x 555 x 418 mm 536 x 585 x 463 mm 580 x 685 x 490 mm
Passive Stage monitor Passive Stage monitor
LF transducer 1" Exit-1.35" Compression Driver
Dispersion angle (HxV): 80° x 80° 80° x 80° 80° x 80°

Version 1.0
This manual suits for next models
5
Table of contents
Other Power works Speakers manuals