Pragmat ZN901A-15L User manual

Instruction Manual
Components
ZN901A-15L
Productprofile
Multiple filters topreventsecondarypollution Hose
Equipped withvariouskindsofnozzle, one machine with Handle
multifunction
Switch
Manualwindingofthe cord
Lock
Metalextension tube
Note:Thisproductisa vacuumcleanerdesigned forlarge places,
suitable forhome use, industrialpurpose and hotelsetc.
Itadoptsthe multiple filters and notonlycanabsorbdust
completely, butalsoensure thatthe exhausted airisclean and can
avoidsecondarypollution.
Withvariouskindsofnozzle it notonlycanabsorbduston carpet,
flooring, butalsoduston wall, ceiling, sofa, bed, and duston the
surface ofvariouskindsofhouseholdappliance.
Manualwindingofthe cord
Lock
Tank
Up/downswitch forfloornozzle Floornozzle Rollerwheel

PointsforAttention
Mountthe elbow tube tothe hose
Mountthe hose tothe tank
Holdon the hose connectorand insertit intothe inletopening.and
make sure thatthe bayonetcouplers catch theirtracks. Then push
forwardand turnclockwise until the couplinglocks. When
disassemblingthe hose turncounterclockwise and pull it out.(F
Donotletthisvacuumcleanernearthe furnace and
subjectwithhighertemperature inordertoavoidplastic
deformation and damage. (Fig.1)
Avoidbending, stampingand draggingthe hose. Do
notuse the vacuumcleanerwhen hose damaged.
(Fig.2)
Please disconnectthe powercordplugwhen you don
tuse the vacuumcleaner, aswell asformaintenance
workand cleaning. Please holdon the plugand do not
dragthe powercordwhile insertingand pluggingthe
cord.(Fig.3)
Before usingthe vacuumcleaner, please checkif
filter, filtersponge, paperbagorclothbagare properly
mounted. please don tuse the vacuumcleanerwhen
above partsdo notexist.
(
Fig.4
)
Mountingthe assembly
When connectinginsertthe elbow tube intothe biggerhole ofthe
extension tube then swivelit tofirmconnection. (Fig.9)
The method ofconnectingthe extension tubesisthe same atabove
(you canuse one extension tube ortwo).
Amountthe extension tube tothe floornozzle
When connectinginsertthe smallerend ofthe extension tube intothe
floornozzle than swivelit tofrimconnection. (Fig.10)
1
2
3
8
9
1
0
管
地面刷
Begintouse
Powercord Crank
When using the vacuum cleaner, do not
absorb hair group, large ball of paper and
other items that may make the absorbing
inlet, tube and hose get blocked. Otherwise
it may cause malfunction or deformation. If
these items were absorbed please disconnect
Please use a clothdampened withwaterormildsoap
forcleaningthe vacuumcleaner. Donotuse gasoline,
banana oil, otherwise it will lead tocrackorfade.
(Fig.7)
Connection method forcrevice nozzle and upholsterybrushisthe
same asabove.
While absorbingplease do notabsorbmud, gypsum
material, wall powderetc. otherwise the vacuumcleaner
filtercancause blockage and the motorwill be burned. If
these small particleswere absorbed please clean the dust
bagorfilter.(Fig.6)
above partsdo notexist.
(
Fig.4
)
The effective lengthofpowercordis4meters.
Unplugthe plugfromthe socketwhen you have finished usingit and
rewind the powercordwiththe crankintothe windingroll inside the
vacuumcleaner.(Fig.11)
Powersource
Afterinsertingthe plugintothe powersocket, press the position "1"or
the green switch the vacuumcleanerwill work. Press the position "0"
orthe red switch the vacuumcleanerwill stop working.
4
6
7
10
11
12
5

Trouble
Remove the
obstruction intime,
emptythe tank, clean
the filterand
reassemble the
extension tube.
1)Holdon the lockon bothsidesofthe productand
rotate it outwardstoopen. Then graspthe handle up to
carryoutthe motorhead.(Fig.16)
2)Graspthe handle withone hand and the filterwith
the otherhand and then rotate it counterclockwise to
remove.(Fig.17)
2.Checkifthe tankisfull.
3.Checkifthe filterisclogged,
the suction powerswitch isfully
turned on and extension tube is
connected correctly.
Turnthe adjustable switch leftorrighttosetup
absorbingorairblowingfunction
Turnlefttothe end the vacuumcleanerwill be used for
absorbingand turnrighttothe end it will be used forair
blowing.(Fig.15)Adjustable switch
Please use upholsterybrushforcleaningsofa, curtain
orduston the decoratingsurfaces. Use floornozzle for
common placessuch ascarpetand floor.(Fig.14)
Operation method forremovingand cleaningthe
filter 1.Checkifthe floorbrush, hose
and extension tube were
clogged.
The suction poweris
reduced
Insertthe pluginto
the socketagainand
make sure thatthe
sockethaspower.
And turnon the
switch.
Possible cause Solution
The machine doesnot
start
1.Checktosee ifthe powerplug
isstablyconnected tothe
socket.
2.Checktosee ifthe power
switch wasturned on.
Troubleshooting
Before contactanauthorised service workshop, please checkthe following
pointsfirst.
Operationmethods
Forcleaningincorners and crevicesyou canuse
crevice nozzle.(Fig.13) 13
1
4
7
Model Voltage Frequency
ZN901A-15L 220~240V 50HZ
connected correctly.
3)Clean the filterwithrunningwaterfirstand then slap
it withhand orswingit. Afterremovingthe waterletit
dried inthe airorinthe shade. Don tdryit withdryerin
ordertoavoiddeformation caused byhightemperature.
(Fig.18)
Range ofpower
1200/1400W
7
8